• 제목/요약/키워드: Compton suppression Spectrometer

검색결과 4건 처리시간 0.021초

Performance of a Compton Suppression Spectrometer of the SNU-KAERI PGAA Facility

  • Sun Gwang Min;Park Chang Su;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.347-355
    • /
    • 2003
  • The \gamma-ray spectrometer of the PGAA (Prompt Gamma Activation Analysis) facility constructed at HANARO of the Korea Atomic Energy Research Institute was upgraded to the multi-mode spectrometer including the single mode, the Compton suppression mode and the pair mode. The performance of the spectrometer was tested and summarized. The background count rate and the uncertainty of the detection efficiency were reduced greatly in comparison with those before the new installation.

몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구 (Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression system은 스펙트럼에서 Compton continuum으로 존재하는 영역을 억제하는 장치 이다. 본 연구에서는 HPGe-NaI(TI)의 기하학적인 구조 파악 및 이동에 따른 이 때 그 효과를 최적화 할 수 있는 배치구조를 찾기 위하여, Monte Carlo simulation을 통해 Compton suppression의 행태적 특성을 파악하고, 몇 가지 배치구조에 대한 비교를 해보았다. 또한 거리에 따른 효율을 이용하여 환경 측정에 사용되는 실린더 비커에 적용해 보았다. ARF 값은 81.1 keV의 경우 약 1.65, 1332.4 에너지의 경우 약 1.9 정도로 나타내는 것을 확인할 수 있다. NaI(Tl) 검출기들의 위치 이동에 따라 특정한 영역에서 suppression이 일어나는 확인할 수 있다. Compton suppression system 구성의 목적에 비추어 볼 때, 결과 에너지 스펙트럼의 Compton continuum 영역 전반에 걸쳐 suppression이 이루어지는 것이 더욱 적절한 배치구조가 됨을 알 수 있다. 따라서 최적화된 구조를 통해 다양한 환경시료 측정에 적용할 수 있음을 확인 하였다.

저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가 (Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.123-131
    • /
    • 2018
  • 본 연구는 점 선원인 $^{60}Co$, $^{137}Cs$ 및 혼합부피선원을 이용하여 피크 대 컴프턴 비율, 연속체 배경 스펙트럼을 감소시키기 위해 저 에너지 peak부터 고 에너지 peak에서 측정된 측정치와 PENELOPE와 비교하였다. 또한, 저에너지 부근에서의 변화를 통해 후방산란, 컴프턴 단(compton edge)의 효율 변화를 PENELOPE와 비교하였다. 혼합부피 선원에서 나온 결과를 토양시료에 적용하여 억제와 비 억제(unsuppressed)모드에서 토양시료의 최소검출한계치가 얼마큼 감소하였는지 확인하고자 한다. $^{60}CO$(1,173 keV)의 저에너지 영역의 컴프턴 억제가 상당히 되었으며, $^{137}Cs$(661 keV) 피크에 대한 Compton edge의 RF는 2.8이다. 특히, $^{60}Co$ 선원은 1,173.2keV와 1,332.5 keV의 coincidence 감마선을 방출하므로 컴프턴 억제는 대략 21% 감소하였다. 60Co 선원에서 방출되는 1,173keV와 1,332keV의 compton edge의 RF는 3.2, 3.4였으며 피크대 컴프턴 edge비율은 8:1로 향상되었다. 그리고, PENELOPE와 비교했을 때 불확도는 2% 이내로 잘 일치하였다. Compton unsuppressed 모드에서 661 keV, 1,173 keV 및 1,332 keV의 MDA 값은 각각 0.535, 0.173 및 0.136Bq/kg이었으나, Compton suppressed 모드에서는 0.121, 0.00826 및 0.00728B/kg로 감소하였다. 따라서, Compton suppres sed는 배후방사능과 검출기 자체에 함유된 방사능을 줄일 수 있었다.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.