• Title/Summary/Keyword: Compressor room

검색결과 77건 처리시간 0.026초

냉장고 기계실 유로 최적화를 통한 소비 전력 저감 (Optimization of refrigerator machine room for energy saving)

  • 김영국;한병윤;김재열;김태훈;이연원;김남식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.101-106
    • /
    • 2002
  • In the Refrigeration and air conditioning industrial circles, refrigerator is demands a high degree of efficiency due to the Environmental Preservation Law. Many researchers are working on factors to improve the efficiency of the refrigerator In this paper, a study of the factors on the decrease of electric power consumption, several experiments are performed to improve the fluid flow in the refrigerator machine room. As a results, average temperatures of compressor and condenser are reduced 3.1$^{\circ}C$, 2.$0^{\circ}C$. The consuming electric power rate is reduced 0.7kWh/month.

  • PDF

차량용 가변용량 압축기의 사판 거동에 관한 연구 (A Study on the Swash Plate Behavior of Variable Displacement Compressor for Automotive Air Conditioning System)

  • 이태진;이건호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1335-1340
    • /
    • 2004
  • Due to the distinct advantages of comfort, drive ability and fuel economy standard, the variable displacement swash plate type compressor which can control the compressor displacement by increasing or reducing the swash plate angle has been developed for automotive air-conditioning system. That can be obtained constant temperature of car room on the variation cooling capacities or engine speeds. This paper was carried out the analysis of swash plate behavior to obtain the forces and moments applied to the swash plate and to get the variable controlability on the variation of compressor speeds and swash plate chamber pressures. The results of simuation agree very well with the experimental data.

  • PDF

자동차용 에어컨 시스템의 성능해석에 관한 연구 (A Study on the Performance Analysis of Automotive Air Conditioning System)

  • 이대웅;유성연
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.304-314
    • /
    • 2002
  • Performance analysis of the automotive air-conditioning system is conducted by using computer simulation, and performance tests are carried out by using the climate wind tunnel in order to verify simulation. Evaporator and condenser were modeled by using empirical correlation which was obtained from calorimeter data, and compressor was modeled by using map based method. The steady state thermodynamic conditions of refrigerant satisfying mass and energy balance were assumed in the simulation program for automotive airconditioning system. The system performance was analyzed by finite difference method until differential air enthalpy between evaporator inlet and outlet becomes converged. Simulation results are in good agreement with experimental results at most operating conditions. Variation of discharge temperature and pressure of compressor, outlet temperature of evaporator, cooling capacity, and COP were investigated in term of air volume flow rate for evaporator, compressor capacity, compressor speed, superheat of thermostatic expansion valve, and diameter of suction line.

내부제어밸브를 가진 가변 사판식 압축기의 소음개선에 관한 연구 (A Study of Noise Improvement of variable displascement swash plate type compressor with internal control valve)

  • 한규석;노경덕;공문성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.165-168
    • /
    • 2006
  • Due to the distinct advantages of comfort, drive ability and fuel economy standard, the variable displacement swash plate type compressor which can control the compressor displacement by increasing of reducing the swash plate angle has developed for automotive air-conditioning system. That can be obtained constant temperature of car room on the variation cooling capacities of engine speeds. In this paper we investigated the improvement of internally controlled variable displacement swash plate compressor on noise.

  • PDF

참치 어선 냉동장치의 개발에 관한 연구 (Development of Refrigeration Equipment for Tuna Long Liner)

  • 오후규;정재천;김성규;구학근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권4호
    • /
    • pp.78-87
    • /
    • 1992
  • The experimental study and theoretical analysis are made in order to investigate a new refrigeration system, R-22 and R-502 or R-13 cascade compressor with panel type cooler, for tuna long liner. The experimental apparatus consists with the cascade unit, 1.5 HP R-502 compressor in the first stage and 1 HP R-22 compressor in the second stage, and 3 $m^2$ cold storage room with a direct expansion panel type cooler. The main result are as follows: 1. The energy saving and C.O.P. of the R-22 and R-502 or R-22 and R-13 cascade are improved much higher than two stage compressor. 2. For the point of simplicity of design, installation, and running cost, the panel type cooler is much better than traditional hair pin coil type cooler. 3. From the experimental data and analysis, the R-22 and R-502, or R-22 and R-13 cascade compressor with panel type cooler is recommended for a new refrigeration equipment of the tuna long liner.

  • PDF

AE 신호를 이용한 회전형 압축기의 이상상태 감시 (The Abnormal Condition Monitoring of Rotary Compressor using Acoustic Emission)

  • 이감규;정지홍;김전하;강명창;김정석
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.118-123
    • /
    • 2004
  • The compressor has one of important roles in refrigeration cycle and it determines refrigeration efficiency and quality This paper aims to monitor rotary compressors for room air conditioners by using Acoustic Emission(AE) technique. The reliability of rotary compressors has been evaluated through visual inspection on them after long term test. This paper describes methods for acquisition and processing AE raw signal to monitor the state of rotary compressor. A detecting method of abnormal compressor in real time is suggested and special-purpose monitoring system which can be applied to automatic manufacturing line is developed using one-chip microprocessor at low cost.

압축기의 수명실험에서의 AE 신호를 이용한 상태감시 (State Monitoring of Compressor using AE Signal in Life Test)

  • 정지홍;강명창;노태영;이감규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.56-60
    • /
    • 1997
  • The compressor is one of important elements in refrigeration cycle and play an important role of refrigeration efficiency and quality. This paper analyzes slides in rotary compressors for room air conditioners, monitoring using Acoustic Emission(AE) technique. Reliability of rotary compressors which are factory-tested has been evaluated through visual inspection on taking them apart after long term test, which is life test. This paper describes methods for acquisition and processing of Acoustic Emission(AE) raw signal to monitor state of rotary compressor in Life Test.

  • PDF

인버터를 이용한 냉동용 압축기의 용량 제어 (Control of Refrigerating Compressor Capacity Using Inverter)

  • 양현석;김환성;김정훈;김상봉;김종수
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성 (Characteristics of Ondol Heating Load for the Determination of Heat Pump Power)

  • 노정근;백은기;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.217-224
    • /
    • 2003
  • To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

냉장고 진동 저감을 위한 그로멧의 유한요소모델링 (Finite Element Modeling for rubber grommet to reduce vibration refrigerator)

  • 국정환;;김정선;왕세명;이동현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.947-950
    • /
    • 2007
  • In this study, vibration analysis of a refrigerator was carried out to reduce vibration by considering grommet. When the refrigerator machine room is modeled by finite element method, spring elements are added to constructions of the FEmodel for each component and update. To design the grommet of refrigerator, FEmodel must have vibration characteristics of each components such as baseplate, pipe and compressor it self. The modal analyses are conducted to validate suggested approach when the components of machine room are assembled together. And, in this study, optimal design of grommet is conducted to avoid the resonance at the operating frequency of refrigerator. The experimental and FEM result of suggested design showed good agreement and are presented here.

  • PDF