Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .
Primary spinal epidural lymphoma(SEL), i.e. occurring in the absence of any detectable extraspinal lymphoproliferative disorder, is an unusual cause of spinal cord compression. The authors report a 48-year-old, diabetic woman presented with back pain followed by acute paraparesis and voiding difficulty. She had been treated with acupunctures on her back before admission, and complete blood count showed leukocytosis with neutrophilia and increased erythrocyte sedimentation rate(ESR). Thoracic spine magnetic resonance imaging(MRI) revealed an epidural mass extending from T5 to T8 with compression of the spinal cord. Emergency decompressive laminectomy was performed with a tentative diagnosis of spinal epidural abscess, but a B-cell lymphoma was final pathologic diagnosis. Further staging showed no other sites of lymphoma, and the spinal lesion was treated by chemotherapy and radiotherapy. The authors stress that primary SEL can mimic spinal epidural abscess(SEA) in the diabetic patient and should be a diagnostic consideration in patients with a syndrome of acute spinal cord compression manifested by a prodrome of back pain and neuroimaging consistent with an epidural compressive lesion, especially in a diabetic.
We acquired and interpreted more than 650 km of high-resolution seismic reflection profiles in the Hupo Basin, offshore east coast of Korea at
Concrete is a representative heterogeneous material and mechanical properties of concrete are influenced by various factors. Due to the fact that pores in concrete affect determining compressive strength of concrete, studies which deal with distribution and magnitudes of pores are very important. That way, studies using picture imaging have been emerged. Studies on mechanical performance evaluation of structural lightweight foamed concrete and FEM analysis based on picture image are inadequate because lightweight foamed concrete has been researched for only non-structural. Therefore, in this study, cement paste with foaming agent to evaluate mechanical performance is made, FEM analysis with picture image is conducted and young's modulus of experiment and analysis are compared. In this study, dosage of foaming agent is determined 7 level to check pore distribution and water-binder ratio is determined 20% to progress research about structural light weight foamed concrete. Weight of unit volume is minimum at 0.8% of foaming agent dosage. However, weight of unit volume is increased over 0.8% of foaming agent dosage because of interconnection with independent pores. For FEM analysis, cement paste is photographed to use image analyzer(HF-MA C01). Consequently, the fact that Young's Modulus of experiment and FEM analysis are same is drawn by using OOF(Object Oriented Finite elements).
Objective : Hemifacial spasm (HFS) is considered as a reversible pathophysiological condition mainly induced by continuous vascular compression of the facial nerve root exit zone (REZ) at the cerebellopontine angle. As an offending vessel, vertebrobasilar artery tends to compress much more heavily than others. The authors analyzed HFS caused by vertebrobasilar artery and described the relationships between microsurgical findings and clinical courses. Methods : Out of 1,798 cases treated with microvascular decompression (MVD) from Jan. 1980 to Dec. 2004. the causative vessels were either vertebral artery or basilar artery in 87 patients. Seventy-nine patients were enrolled in this study. Preoperatively, computed tomography (CT) or brain magnetic resonance (MR) imaging with 3-dimentional short range MR technique was performed and CT was checked immediately or 2-3 days after anesthetic recovery. The authors retrospectively analyzed the clinical features. the compression patterns of the vessels at the time of surgery and treatment outcomes. Results : There were 47 were male and 32 female patients. HFS developed on the left side in 52 cases and on the right side in 27. The mean age of onset was 52.3 years (range 19-60) and the mean duration of symptoms was 10.7 years. Many patients (39 cases; 49.1%) had past history of hypertension. HFS caused only by the vertebral artery was 8 cases although most of the other cases were caused by vertebral artery (VA) in combination with its branching arteries. Most frequently, the VA and the posterior inferior cerebellar artery (PICA) were the simultaneous causative blood vessels comprising 32 cases (40.5%). and in 27 cases (34.2 %) the VA and the anterior inferior cerebellar artery (AICA) were the offenders. Facial symptoms disappeared in 61 cases (77.2%) immediately after the operation and 68 cases (86.1%) showed good outcome after 6 months. Surgical outcome just after the operation was poor in whom the perforators arose from the offending vessels concurrently (p<0.05). Conclusion : In case where the vertebral artery is a cause of HFS, commonly branching arteries associated with main arterial compression on facial REZ requires more definite treatment for proper decompression because of its relatively poor results compared to the condition caused by other vascular compressive origins.
It is now established that more than two types of blended aggregate have beneficial effects on quality and supply of concrete in the long run. However, studies on blended aggregate have not widely been progressive and the evaluation method of its most favorable mixture proportion is still needed. Therefore this study investigated the most favorable mixture proportion through the physical experiment of fresh and hardened state's cement mortar, in response to three types of composite ratio, natural fine aggregate(Ns), crushed fine aggregate(Cs) and recycled fine aggregate(Rs). Test showed that increase of blending ratio of Ns and Cs improved fluidity of mot1ar. For the properties of compressive and flexural strength, mortar blending Ns and Cs properly, exhibited similar value to one using only Cs, while mortar mixing Rs showed lower strength value as less as 6% of control one. Mortar using only Rs exhibited the largest drying shrinkage value. In addition, even thought it is not a clear quantitative analysis, technical-imaging-skill presenting the most favorable mixture proportion 3-dimensionally is proposed in this research, in order to notify the proportion easily.
In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.
Diffuse large B cell lymphoma (DLBCL) is main subtype of primary thyroid lymphoma and can be histologically transformed from a low-grade B-cell lymphoma. The characteristics and treatment guidelines of these particular DLBCL have not been fully established. The mainstay of treatment of primary thyroid DLBCL is multimodality treatment with chemotherapy and radiotherapy. Meanwhile, surgery can be considered only for diagnosis or alleviation of airway compressive symptoms. A 57-year-old female visited our outpatient clinic for recently enlarged long-held anterior neck mass. A thyroid mass compressing the airway and esophagus was identified on imaging, which was diagnosed as MALT lymphoma by excisional biopsy. After staging, the patient underwent total thyroidectomy with regional lymph node dissection for treatment of stage IIE MALT lymphoma and relieving airway compromise symptoms. The final diagnosis was DLBCL transformed from MALT Lymphoma, and chemotherapy was additionally performed. We report this rare experience with a review of literature.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70