• 제목/요약/키워드: Compressive Strength Reduction factor

검색결과 41건 처리시간 0.031초

TEMPERATURE CONTROL AND COMPRESSIVE STRENGTH ASSESSMENT OF IN-PLACE CONCRETE STRUCTURES USING THE WIRELESS TEMPERATURE MEASURING SYSTEM BASED ON THE UBIQUITOUS SENSOR NETWORK

  • Ho Kyoo JO;Hyung Rae KIM;Tae Koo KIM
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.794-799
    • /
    • 2009
  • The temperature control of in-place concrete is the most important factor for an early age of curing concrete. Heat stress of mass concrete caused by the heat of hydration can induce the crack of concrete, and a frost damage from cold weather casting concrete results defect on compressive strength and degradation of durability. Therefore, success and failure of concrete work is dependant on the measurement and control of concrete temperature. In addition, the compressive strength assessment of in-place concrete obtained from the maturity calculated from the history of temperature make a reduction of construction cycle time, possible. For that purpose, wireless temperature measuring system was developed to control temperature and assess strength of concrete. And, it was possible to monitor the temperature of concrete over 1km apart from site office and to take a proper measure; mesh-type network was developed for wireless sensor. Furthermore, curing control system that contains the program capable to calculate the maturity of concrete from the history of temperature and to assess the compressive strength of concrete was established. In this study, organization and practical method of developed curing control system are presented; base on in-place application case.

  • PDF

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

실리카흄을 사용(使用)한 투수(透水)콘크리트의 강도(强度) 및 동결융해저항성(凍結融解抵抗性) (Increase of strength and freezing-thawing resistance of porous concrete by Silica-fume)

  • 홍창우
    • 자원리싸이클링
    • /
    • 제19권4호
    • /
    • pp.35-40
    • /
    • 2010
  • 최근에 들어 투수콘크리트의 동결융해에 대한 저항성이 저하되는 것과 줄눈부에서의 골재박리 등의 많은 문제점들이 대두되고 있다. 따라서 본 연구에서는 기존의 투수콘크리트의 내구성을 향상시키기 위한 방안으로 잔골재와 실리카흄, 고성능감수제를 사용하여 강도 및 내구성 증진 방안을 연구하였다. 주요실험인자로 실리카흄 혼입률 10%와 잔골재 혼입률(0%, 7%, 15%)을 선정하고, 압축강도와 휨강도, 투수계수 및 공극률, 동결융해시험을 수행하였다. 실험결과 강도측면에서는 잔골재 혼입률이 증가함에 따라 압축 및 휨강도는 증가하는 경향을 보였으나, 상대적으로 공극률 감소로 인한 투수성은 저하되고, 동결융해 저항성도 크게 감소하는 것으로 나타났다. 따라서 투수콘크리트에 있어서 강도증진을 위해 사용되는 잔골재는 혼입률 제한이 필요하며, 실리카흄 10%이상을 사용하는 것이 강도 및 내구성 측면에서 효율적인 대안이 될 수 있을 것으로 판단된다.

Performance of aerated lightweighted concrete using aluminum lathe and pumice under elevated temperature

  • Mohammad Alharthai;Yasin Onuralp Ozkilic;Memduh Karalar;Md Azree Othuman Mydin;Nebi Ozdoner;Ali Ihsan Celik
    • Steel and Composite Structures
    • /
    • 제51권3호
    • /
    • pp.271-288
    • /
    • 2024
  • The primary objective of this study is to investigate the production and performance characteristics of structural concrete incorporating varying proportions (0%, 25%, and 50% by volume) of pumice stone, as well as aluminum lathe as an additive at 0%, 1%, 2%, and 3%, under fire conditions. The experiment will be conducted over a period of up to 1 hour, at temperatures ranging from 24℃, 200℃, 400℃ and 600℃. For the purpose of this, a total of twelve test samples were manufactured, and then tests of compressive strength (CS), splitting tensile strength (STS), and flexural strength (FS) were performed on these samples.Next, a comparison was made between the obtained values and the influence of temperature. To achieve this objective, the manufactured samples were placed at temperatures of 200℃, 400℃, and 600℃ for a duration of 1 hour, and were subjected to the influence of temperature.These values at 24 ℃ were then contrasted with the CS results obtained from test samples that were subjected to the temperature effect for an hour at 200 ℃, 400 ℃, and 600 ℃. A comprehensive analysis of the test outcomes reveals that the incorporation of aluminum lathe wastes into a mixture results in a significant reduction in the compressive strength of the concrete. As a result of this adjustment, the CS values dropped by 32.93%, 45.70%, and 52.07%, respectively. Furthermore, It was shown that testing the ratios of pumice stone alone resulted in a decrease in CS outcomes. Additionally, it was found that the presence of higher temperatures is clearly the primary factor contributing to the decrease in the strength of concrete. Due to elevated temperatures, the CS values decreased by 19.88%, 28.27%, and 38.61% respectively.After this investigation, an equation that explains the connection between CS and STS was provided through the utilization of the data of the experiments that were carried out.

고성능유동화제가 콘크리트의 공학적 특성에 미치는 영향 (I) (A Study on the Effects of Superplasticizers on the Engineering Preperties of Plain Concrete (I))

  • 박승범;이보성
    • 한국농공학회지
    • /
    • 제26권3호
    • /
    • pp.68-80
    • /
    • 1984
  • This study was attempted in order to investigate the effects of superplasticizers on fresh and hardened concrete. The experimental program included tests on the slump and slump loss, bleeding, time of set, air content, the compacting, factor Vee Dee, compressive strength, tensile and flexural strength, permeability, shrinkage and freege-thaw durability. The major conclusions that can be drawn on the study are as follows. 1. Superplasticizers were observed to have an appreciable fluidifying action in fresh concrete so that tinder appropriate conditions, they either considerably improved its workability or permitted a water reduction of at least 8-12% to be made while maintaining normal workability. 2. The bleeding ratios of base and S,P. Concrete were much lower than those of the conventional concrete. Differences between the base and S.P. Concrete were insignifician. 3. The setting time was the longest for conventionla concrete, followed by S.P. concrete and base concrete in thatorder. And AE water reduction admixtures showed an appreciable influence on the setting and hardening characteristics of concrete and prolonged the stiffening times. 4. The high initial slump values of S.P. concrete generally decreased rapidly with increased standing time. CF values showed increasing tendencies with the increase of S.P. content, and excessive addition of S.P. caused the segregation of fresh concrete, resulting in its rejection. 5. Though there was a slight increase in strength, no significant differences are observed between base and S.P. concrete in terms of the compressive, tensile and flexural strength. 6. The permeability of S.P. concrete was significantly less than that of the conventional concrete, and the shrinkage of S.P. concrete was considerably smaller than that of the conventional concrete, but there were no significant differences between base and S.P. concrete. 7. Compared to base concrete, S.P. concrete without entrained air tended to slightly increase freeze-thaw durability, and S.P. concrete with an appropriate entrained air gave satisfactory resistance to freezing and thawing.

  • PDF

산업부산물을 이용한 섬유보강 포장용 포러스콘크리트의 특성에 관한 연구 (A Study on the Properties of Fiber Reinforced Porous Concrete for Pavement using Industrial By-product)

  • 박승범;이윤선;이준;장영일;김봉균;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.699-702
    • /
    • 2005
  • This study evaluates the properties of porous concrete for pavement according to content of silica fume and steel fiber. The results of the test indicate that in every condition, the void ratio and the coefficient of water permeability of porous concrete for pavement satisfy both the domestic standards and proposition values. Among the properties of strength, the compressive strength satisfies the standards in the specification of KNHC as for every factor of mixture but in the case of the flexural strength, more than $0.6vol.\%$ of steel fiber satisfied the JCI proposition values. The case when silica fume and steel fiber are used simultaneously presents the strongest durability and Noise Reduction Coefficient is 0.48 to prove that it possesses almost $50\%$ sound absorption.

  • PDF

순환굵은골재 치환율에 따른 콘크리트의 역학적 특성 (The Effect of Recycled Coarse Aggregate Replacement Level on the Mechanical Properties of Concrete)

  • 전에스더;윤현도;유영찬;이세현;심종우;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.505-508
    • /
    • 2006
  • This experimental study is to evaluate the effects of recycled coarse aggregate replacement level on the mechanical properties of concrete produced at Batcher plant. The main test parameter was replacement level of recycled coarse aggregate with the ratio of 0, 30, 60 and 100% to the natural coarse aggregate. From the test results, it was found that compressive strength, elastic modulus and splitting strength are decreased with the increased proportion of replacement level. Therefore, some design coefficients or recommendations for elastic modulus and splitting strength of concrete need to be reconsidered with minor reduction factor of '0.85'.

  • PDF

Seismic bearing capacity of shallow embedded strip footing on rock slopes

  • Das, Shuvankar;Halder, Koushik;Chakraborty, Debarghya
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.123-138
    • /
    • 2022
  • Present study computes the ultimate bearing capacity of an embedded strip footing situated on the rock slope subjected to seismic loading. Influences of embedment depth of strip footing, horizontal seismic acceleration coefficient, rock slope angle, Geological Strength Index, normalized uniaxial compressive strength of rock mass, disturbance factor, and Hoek-Brown material constant are studied in detail. To perform the analysis, the lower bound finite element limit analysis method in combination with the semidefinite programming is utilized. From the results of the present study, it can be found that the magnitude of the bearing capacity factor reduces quite substantially with an increment in the seismic loading. In addition, with the increment in slope angle, further reduction in the value of the bearing capacity factor is observed. On the other hand, with an increment in the embedment depth, an increment in the value of the bearing capacity factor is found. Stress contours are presented to describe the combined failure mechanism of the footing-rock slope system in the presence of static as well as seismic loadings for the different embedment depths.

Size effect on strength of Fiber-Reinforced Self-Compacting Concrete (SCC) after exposure to high temperatures

  • Gulsan, M. Eren;Abdulhaleem, Khamees N.;Kurtoglu, Ahmet E.;Cevik, Abdulkadir
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.681-695
    • /
    • 2018
  • This pioneer study investigates the size effect on the compressive and tensile strengths of fiber-reinforced self-compacting concrete (FR-SCC) with different specimens, before and after exposure to elevated temperatures. 432 self-compacting concrete (SCC) specimens with two concrete grades (50 and 80MPa) and three steel fiber ratios (0%, 0.5% and 1%) were prepared and tested. Moreover, based on the experimental results, new formulations were proposed to predict the residual strengths for different specimens. A parametric study was also carried out to investigate the accuracy of proposed formulations. Residual strength results showed that the cylinder specimen with dimensions of $100{\times}200mm$ was the most affected, while the cube with a size of 100 mm maintained a constant difference with the standard cylinder ($150{\times}300mm$). Temperature effect on the cube specimen (150 mm) was the least in comparison to other specimen sizes and types. In general, provision of steel fibers in SCC mixtures resulted in a reduction in temperature effect on the variance of a conversion factor. Parametric study results confirm that the proposed numerical models are safe to be used for all types of SCC specimens.

폴리프로필렌 섬유 보강 EVA 콘크리트의 압축강도 및 내구성 (The Compressive Strength and Durability Properties of Polypropylene Fiber Reinforced EVA Concrete)

  • 남기성;성찬용
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.11-19
    • /
    • 2015
  • The important properties of EVA (ethylene vinyl acetate) redispersible polymer was waterproof, densification of internal pore space of concrete and ball bearing and micro filler. Also, the significant role of polypropylene(PP) fiber was crack control and blockade of movement for deterioration factors. The most studies for EVA were limited in the field of mortar and PP fiber reinforced concrete had been studied in the state of being restricted unit water content, rich mix and mixing much of the fiber without considering construction site. Therefore, the control mix design were applied in ready mixed concrete using 10 % fly ash of total cement weight used in batch plant. On the basis of control mix design, EVA contents ranging from 0 % to 10 % of total cement weight and PP fiber contents ranging from 0 % to 0.5 % of EVA concrete volume were used in the mix designs. The results showed the maximum compressive strength value was measured at EVA 5.0 % and PP fiber 0.1 %, the minimum water absorption ratio was at EVA 10 % and PP fiber 0 %, the durability factor for freezing and thawing resistance was at EVA 5.0 % and PP fiber 0.3 % and the minimum weight reduction ratio of resistance to sulfuric acid attack was at EVA 10 % and PP fiber 0.5 % after curing age 42days. Meanwhile, From these results, PP fiber reinforced EVA concrete would be very benefit, if each optimal mix types were used in hydraulic structures, underground utilities and agricultural structures.