• Title/Summary/Keyword: Compressive Failure Strength

Search Result 698, Processing Time 0.024 seconds

Strength criterion of plain recycled aggregate concrete under biaxial compression

  • He, Zhen-Jun;Liu, Gan-Wen;Cao, Wan-Lin;Zhou, Chang-Yang;Jia-Xing, Zhang
    • Computers and Concrete
    • /
    • v.16 no.2
    • /
    • pp.209-222
    • /
    • 2015
  • This paper presents results of biaxial compressive tests and strength criterion on two replacement percentages of recycled coarse aggregate (RPRCA) by mass for plain structural recycled aggregate concrete (RAC) at all kinds of stress ratios. The failure mode characteristic of specimens and the direction of the cracks were observed and described. The two principally static strengths in the corresponding stress state were measured. The influence of the stress ratios on the biaxial strengths of RAC was also analyzed. The experimental results showed that the ratios of the biaxial compressive strength ${\sigma}_{3f}$ to the corresponding uniaxial compressive strength $f_c$ for the two RAC are higher than that of the conventional concrete (CC), and dependent on the replacement percentages of recycled coarse aggregate, stress states and stress ratios; however, the differences of tensile-compressive ratios for the two RAC and CC are smaller. On this basis, a new failure criterion with the stress ratios is proposed for plain RAC under biaxial compressive stress states. It provides the experimental and theoretical foundations for strength analysis of RAC structures subject to complex loads.

Multiscale modeling for compressive strength of concrete columns with circular cross-section

  • Wu, Han-liang;Wang, Yuan-feng
    • Computers and Concrete
    • /
    • v.15 no.6
    • /
    • pp.865-878
    • /
    • 2015
  • In order to construct a multiscale model for the compressive strength of plain concrete columns with circular cross section subjected to central longitudinal compressive load, a column failure mechanism is proposed based on the theory of internal instability. Based on an energy analysis, the multiscale model is developed to describe the failure process and predict the column's compressive strength. Comparisons of the predicted results with experimental data show that the proposed multiscale model can accurately represent both the compressive strength of the concrete columns with circular cross section, and the effect of column size on its strength.

Compressive strength and failure behaviour of fibre reinforced concrete at elevated temperatures

  • Shaikh, F.U.A.;Taweel, M.
    • Advances in concrete construction
    • /
    • v.3 no.4
    • /
    • pp.283-293
    • /
    • 2015
  • This paper presents the effects of elevated temperatures of $400^{\circ}C$ and $800^{\circ}C$ on the residual compressive strength and failure behaviour of fibre reinforced concretes and comparison is made with that of unreinforced control concrete. Two types of short fibres are used in this study e.g., steel and basalt fibres. The results show that the residual compressive strength capacity of steel fibre reinforced concrete is higher than unreinforced concrete at both elevated temperatures. The basalt fibre reinforced concrete, on the other hand, showed lower strength retention capacity than the control unreinforced concrete. However, the use of hybrid steel-basalt fibre reinforcement recovered the deficiency of basalt fibre reinforced concrete, but still slightly lower than the control and steel fibres reinforced concretes. The use of fibres reduces the spalling and explosive failure of steel, basalt and hybrid steel-basalt fibres reinforced concretes oppose to spalling in deeper regions of ordinary control concrete after exposure to above elevated temperatures. Microscopic observation of steel and basalt fibres surfaces after exposure to above elevated temperatures shows peeling of thin layer from steel surface at $800^{\circ}C$, whereas in the case of basalt fibre formation of Plagioclase mineral crystals on the surface are observed at elevated temperatures.

Experimental investigation on steel-concrete bond in lightweight and normal weight concrete

  • Chen, How-Ji;Huang, Chung-Ho;Kao, Zhang-Yu
    • Structural Engineering and Mechanics
    • /
    • v.17 no.2
    • /
    • pp.141-152
    • /
    • 2004
  • The bonding behaviors of Lightweight Aggregate Concrete (LWAC) and normal weight concrete were investigated experimentally. Pull-out tests were carried out to measure the bond strengths of three groups of specimens with compressive strength levels of 60, 40, and 20 MPa, respectively. Test results showed that the difference in the bond failure pattern between LWAC and normal weight concrete was significant as the concrete compressive strength became lower than 40 MPa. The corresponding bond strengths of LWAC were lower than that for normal weight concrete. As the compressive strength of concrete became relatively high (> 40 MPa), a bond failure pattern in normal weight concrete occurred that was similar to that in LWAC. The bond strength of LWAC is higher than that for normal weight concrete because it possesses higher mortar strength. Stirrup use leads to an increase of approximately 20% in nominal bond strength for both types of concrete at any strength level.

Experimental research on the failure mechanism of foam concrete with C-Channel embedment

  • Liu, Dianzhong;Wang, Fayu;Fu, Feng;Wang, He
    • Computers and Concrete
    • /
    • v.20 no.3
    • /
    • pp.263-273
    • /
    • 2017
  • An experimental investigation is carried out on the failure mechanism of foam concrete with cold formed steel double C-Channels embedment. The foam concrete is made of cement and fly ash with a compressive strength between 9 and 24 MPa with different densities. Forty-eight tests have been carried out in four groups of specimens with various embedment depths of the steel in the concrete. Four modes of failure are observed, which include the independent failure of the C-Channels with and without a concrete block inside the channel as well as the combined failure of the two channels, and the failure of the extrusion block. A theoretical model has been developed to understand the failure process. The peak compressive force applied onto the C-Channels that causes failure is calculated. It is concluded that the failure involves independent slippage between two C-Channels, and the steel and the foam concrete blocks inside the C-Channels. A method to calculate the peak force is also developed based on the test results. The calculations also show that the shear strength of the foam concrete is about 8% of the compressive strength with ${\alpha}$ coefficient of 0.4 between the steel and concrete.

An Experimental Study on the Compressive Strength of Reinforcing Bars in Concrete Specimens and Compressive Strength Measurement Methods (콘크리트 압축강도 측정법과 공시체 내 철근이 압축강도 측정에 미치는 실험적 연구)

  • Lee, Won-Hong;Choi, Sang-Gi;Lee, Seuong-Yeol;Ahn, Jin-Hee;Kang, Beom-Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.33-40
    • /
    • 2021
  • Measuring the compressive strength of concrete is a very important factor in the safety review of concrete structures. Concrete compressive strength measurement methods include destructive and non-destructive methods. The destructive method includes the uniaxial compression failure method, and the non-destructive method includes the rebound hardness method and the elastic wave measurement method. In this study, the type of measurement method and the effect of reinforcing bars inside the concrete were tested to examine the relationship between them. Regardless of the type of specimen, the average compressive strength by the elastic wave measurement method among the three experimental methods was greater than the average compressive strength by the other methods. When the specimen type is the same, the standard deviation of the measured values of the elastic wave measurement method is smaller than that of the other measurement methods, so it can be seen that the elastic wave measurement method does not show large variance in the measured values compared to the other two measurement methods. When the average compressive strength according to the test method for each specimen was compared with the average compressive strength of the compressive failure test method, the average compressive strength was measured to be high in the order of the elastic wave measurement method, the compression failure test, and the rebound hardness method. Since the measured values of the compressive strength of concrete are different depending on the method of measuring the compressive strength of concrete and the presence or absence of reinforcing bars inside the concrete, further research is required considering the effect of various concrete covers.

Experimental study on strength anisotrophy of basalt in Cheju usland (제주도 현무암의 강도이방성에 대한 실험적 연구)

  • Song, Young-Suk;Nam, Jung-Mann;Yun, Jung-Mann
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1057-1062
    • /
    • 2008
  • In order to investigate a strength anisotrophy of basalt in Cheju Island, rock samples of Pyosenri basalt, trachy-basalt and scoria were taken from Seoguipo-Si Seongsan-Eup area, and a series of uniaxial compressive strength test and Brazilian test were carried out. The strengths were decreased with increasing the moisture contents in rock sample by pore water. As the result of test considering the anisotropy of rock strength, the compressive strength in condition of failure occurred parallel to stratified layer is decreased about 12-26% more than that in condition of failure occurred inclined to stratified layer.

  • PDF

Failure and Deformation Characteristics of Rock at High and Low Temperatures (고온 및 저온하에서의 암석의 변형, 파괴 특성)

  • 정재훈;김영근;이형원;이희근
    • Tunnel and Underground Space
    • /
    • v.2 no.2
    • /
    • pp.224-236
    • /
    • 1992
  • It is very important to determine the thermo-mechanical characteristics of the rock mass surrounding the repository of radioctive waste and the LPG storage cavern. In this study, Hwasoon-Shist. Dado-Tuff adn Chunan-Tonalite were the selected rock types. Temperature dependence of the mechanical properteis such as uniaxial compressive strength, tensile strength, Young's modulus was investigated by measuring the behaviour of these properties due to the variation of temperature. Also, the characteristics of strength and deformation of these rocks were examined through high-temperature triaxial compression tests with varing temperatures and confining pressures. Important results obtained are as follows: In high temperature tests, the uniaxial compressive strength and Yong's modulus of Tonalite showed a sligth increase at a temperature up to 300$^{\circ}C$ and a sharp decrease beyond 300$^{\circ}C$, and the tensile strength showed a linear decrease with increasing heating-temperature. In high-temperature triaxial compression test, both the failure stress and Young's modulus of Tonalite increased with the increase of confining pressure at constant heating-temperature, and the failure stress decreased at 100$^{\circ}C$ but increased at 200$^{\circ}C$ under a constant confining pressure. In low temperature tests, the uniaxial compressive and tensile strengths and Young's modulus of these rocks increased as the cooling-temperature is reduced. Also, the uniaxial compressive and tensile strengths of wet rock specimens are less than those of dry rock specimens.

  • PDF

Ultimate compressive strength predictions of CFT considering the nonlinear Poisson effect

  • Yu-A Kim;Ju-young Hwang;Jin-Kook Kim
    • Steel and Composite Structures
    • /
    • v.48 no.4
    • /
    • pp.461-474
    • /
    • 2023
  • Concrete-filled steel tubes are among the most efficient compressive structural members because the strength of the concrete is enhanced given that the surrounding steel tube confines the concrete laterally and the steel tube is restrained with regard to inward deformation due to the concrete existing inside. Accurate estimations of the ultimate compressive strength of CFT are important for efficient designs of CFT members. In this study, an analytical procedure that directly formulates the interaction between the concrete and steel tube by considering the nonlinear Poisson effect and stress-strain curve of the concrete including the confinement effect is proposed. The failure stress of concrete and von-Mises failure yield criterion of steel were used to consider multi-dimensional stresses. To verify the prediction capabilities of the proposed analytical procedure, 99 circular CFT experimental data instances from other studies were used for a comparison with AISC, Eurocode 4, and other researchers' predictions. From the comparison, it was revealed that the proposed procedure more accurately predicted the ultimate compressive strength of a circular CFT regardless of the range of the design variables, in this case the concrete compressive strength, yield strength of the steel tube and diameter relative to the thickness ratio of the tube.

Strength Prediction of Spatially Reinforced Composites (공간적으로 보강된 복합재료의 강도예측)

  • 유재석;장영순;이상의;김천곤
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.39-46
    • /
    • 2004
  • In this study, the strength of spatially reinforced composites (SRC) are predicted by using stiffness reduction for each structural element composed of a rod stiffness in each direction and a matrix stiffness proportional to its rod volume fraction. Maximum failure strain criteria is applied to rod failure, and modified Tsai-Wu failure criteria to matrix failure. The material properties composed of the tensile failure strain of a rod, the compressive failure strain of 3D SRC, the tensile and compressive strength of the 3D SRC in the $45^{\cir}$ rotated direction from a rod and the shear strength of the 3D SRC are measured to predict the SRC strength. The strength distributions of the 3D/4D SRC in rod and off-rod direction have the largest and the smallest values, respectively. A variable load step is selected to increase an efficiency of strength distribution calculation. Uniform load step is applied when a load history is needed. The results of compressive strength from analysis and experiment show the 18 % difference though the initial slop is coincident with each other.