• Title/Summary/Keyword: Compressive Failure

Search Result 894, Processing Time 0.029 seconds

Recovery of mortar-aggregate interface of fire-damaged concrete after post-fire curing

  • Li, Lang;Zhang, Hong;Dong, Jiangfeng;Zhang, Hongen;Jia, Pu;Wang, Qingyuan;Liu, Yongjie
    • Computers and Concrete
    • /
    • v.24 no.3
    • /
    • pp.249-258
    • /
    • 2019
  • In order to investigate the strength recovery of fire-damaged concrete after post-fire curing, concrete specimens were heating at $2^{\circ}C/min$ or $5^{\circ}C/min$ to 400, 600 and $800^{\circ}C$, and these exposed specimens were soaked in the water for 24 hours and following by 29-day post-fire curing. The compressive strength and split tensile strength of the high-temperature-exposed specimens before and after post-fire curing were tested. The proportion of split aggregate in the split surfaces was analyzed to evaluate the mortar-aggregate interfacial strength. After the post-fire curing process, the split tensile strength of specimens exposed to all temperatures was recovered significantly, while the recovery of compressive strength was only obvious within the specimens exposed to $600^{\circ}C$. The tensile strength is more sensitive to the mortar-aggregate interfacial cracks, which caused that the split tensile strength decreased more after high-temperature exposure and recovery more after post-fire curing than the compressive strength. The mortar-aggregate interfacial strength also showed remarkable recovery after post-fire curing, and it contributed to the recovery of split tensile strength.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

A Study on the Compressive Capacity of Yellow Poplar Skin-timber (백합나무 스킨팀버의 압축 성능에 관한 연구)

  • Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.333-343
    • /
    • 2011
  • The yellow poplar is an appropriate species for the age of low carbon green growth, because its absorption rates of ozone is greatly excellent, and also the absorption rates of carbon dioxide causing climate changes is very remarkable. The yellow poplar, which is a kind of rapid growth tree, shows a lack of performance as a structural member, however, it is suitable to use a variety of purposes like furniture materials, interior materials, plywood materials, and so on. In this study, the structural size skin-timbers were made by using the yellow poplar, and the compressive capacity was evaluated, also the numerical model was developed for the various uses. The rectangular shape skin-timber presented a good performance by showing 56.3% residual strength about the solid material. In case of the cylinder shape skin-timber showed a possibility to use diversely as a furniture material, as well as a structural uses, because almost 50% compressive capacity of material even though its residual area rates was 25%. Both rectangular shape and the cylinder shape represented that 'Brooming or end rolling' were the major failure mode, and partly splitting failure mode. The compressive capacity of the rectangular shape which residual area rates was large was higher than the cylinder shape, but it did not show statistical significance about the compressive capacity between them. Thus, it will be possible to use them mixed for a convenience of users. The result of the numerical analysis model was quite similar to actual test of the compressive capacity. Therefore, the yellow poplar can be utilized in the development of various uses by applying numerical analysis model about a variety of shapes and dimensions.

A Study for Application of 180 MPa Ultra High Performance Concrete to Compressive Members (180MPa 초고성능 콘크리트의 압축 부재에의 적용성에 대한 연구)

  • Min, Kyung-Hwan;Choi, Hong-Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4930-4935
    • /
    • 2015
  • In the actual research fields, the studies for applications of 180 MPa ultra high performance concrete (UHFRCC) to compressive members are limited due to its very high compressive strength. In this study, in order to find its practical use, UHPC was producted by using twin-shaft mixer batch plant. Also, to get basic research data for the design specification of UHPC compressive members, a series of draft experiments, including short columns with square and circular sections, were performed and its failure modes and behaviors were assessed.

A study on the unconfined compressive strength(UCS) of fiber-reinforced soil (섬유보강 혼합토의 일축압축강도 특성에 관한 연구)

  • 장병욱;김강석;박영곤
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.461-466
    • /
    • 1998
  • The purpose of this study was to evaluate the properties of unconfined compressive strength(UCS) of dry soil which was reinforced with short polypropylene fiber(SPPF). And the results were summarized as follows: 1. As water content was increased, unconfined compressive strength and strain of dry soil with no fiber added were decreased 2. As mixing ratio of fiber was increased, unconfined compressive strength and strain at failure of dry soil reinforced with SPPF were increased. 3. When mixing ratio was larger than 0.5%, unconfined compressive strength was gradually increased. 4. The longer fiber was, the larger post peak strength was obtained and the larger strain was reached.

  • PDF

Thickness Effect on Compressive Fatigue Behavior of Al-Si-Ca Alloy Foam (Al-Si-Ca 합금 폼의 피로 거동에 대한 두께 효과)

  • Kim, Il-Hyun;Hossain, Mynul;Kim, Am-Kee
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.179-182
    • /
    • 2007
  • The compressive fatigue tests on the closed cell Al-Si-Ca alloy foams with two different thicknesses were performed using a load ratio of 0.1. The quasi-static and cyclic compressive behaviors were obtained respectively. The fatigue stress-life (S-N) curves were evaluated from the obtained cyclic compressive behaviors. S-N curves were presented for the onset of progressive shortening. It turned out that the fatigue strength showed higher value for the thicker foam and the onset of shortening of thinner foam took place earlier. The crushing was found to initiate in a single band which broadens gradually with additional fatigue cycles. Progressive shortening of the specimen took place due to a combination of low cycle fatigue failure and cyclic ratcheting.

  • PDF

The Effect or Resin ann ruler Type on the compressive strength of Light-activated Composite Resins (광중합형 복합레진의 압축강도에 미치는 레진과 필러의 영향)

  • 원대희
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • This study was performed to evaluate the effect of resin and filler type on the compressive strength of light-activated composite resins. Experimental composite resins containing either amorphous spherical silica or crushed quartz in two matrix resins of BisGMA/TEGDMA and UTMA/TEGDMA were prepared and the specimens of 3 m in diameter and 6m in length were made. Compressive test was subjected to a crosshead speed of 0.5 mm/min, and the fracture surFaces were examined by SEM. The compressive strength of UTMA-based composite resin was higher than that of BisGMA-based composite resin. The loading rate of spherical silica was higher than that of crushed silica when the size dis- tribution of fillers was same. Strength decrease of Bis-GMA-based composite resin was severer than that of UTMA-based composite resin in a $37^{\circ}$c water environment. Fracture surface showed that the composite resin failure developed along the matrix resin and the filler/resin interface region.

  • PDF

Decision of Ultimate Failure Mode of High-Strength Concrete Beams Using Degrading Shear Strength Model (전단내력 감소식을 이용한 고강도 콘크리트 보의 파괴형식 판정 연구)

  • 장일영;송재호;박훈규;황규철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.207-212
    • /
    • 2001
  • The aim of this study is to present a practical and simple method for decision of ultimate failure mode of high-strength concrete beam members, based on interaction between shear strength and displacement ductility. Four tests were conducted on full-scale beam specimens having concrete compressive strength of 410kgf/$cm^{2}$. Prediction of failure mode from presented method and comparison with test results are also presented

  • PDF

Effect of Intermediate Principal Stress on Rock Fractures

  • Chang, Chan-Dong
    • Journal of the Korean earth science society
    • /
    • v.25 no.1
    • /
    • pp.22-31
    • /
    • 2004
  • Laboratory experiments were conducted in order to find effects of the intermediate principal stress of ${\sigma}_{2}$ on rock fractures and faults. Polyaxial tests were carried out under the most generalized compressive stress conditions, in which different magnitudes of the least and intermediate principal stresses ${\sigma}_{3}$ and ${\sigma}_{2}$ were maintained constant, and the maximum stress ${\sigma}_{1}$, was increased to failure. Two crystalline rocks (Westerly granite and KTB amphibolite) exhibited similar mechanical behavior, much of which is neglected in conventional triaxial compression tests in which ${\sigma}_{2}$ = ${\sigma}_{3}$. Compressive rock failure took the form of a main shear fracture, or fault, steeply dipping in ${\sigma}_{3}$ direction with its strike aligned with ${\sigma}_{2}$ direction. Rock strength rose significantly with the magnitude of ${\sigma}_{2}$, suggesting that the commonly used Mohr-type failure criteria, which ignore the ${\sigma}_{2}$ effect, predict only the lower limit of rock strength for a given ${\sigma}_{3}$ level. The true triaxial failure criterion for each of the crystalline rocks can be expressed as the octahedral shear stress at failure as a function of the mean normal stress acting on the fault plane. It is found that the onset of dilatancy increases considerably for higher ${\sigma}_{2}$. Thus, ${\sigma}_{2}$ extends the elastic range for a given ${\sigma}_{3}$ and, hence, retards the onset of the failure process. SEM inspection of the micromechanics leading to specimen failure showed a multitude of stress-induced microcracks localized on both sides of the through-going fault. Microcracks gradually align themselves with the ${\sigma}_{1}$-${\sigma}_{2}$ plane as the magnitude of ${\sigma}_{2}$ is raised.

Analysis for mechanical characteristics and failure models of coal specimens with non-penetrating single crack

  • Lv, Huayong;Tang, Yuesong;Zhang, Lingfei;Cheng, Zhanbo;Zhang, Yaning
    • Geomechanics and Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-365
    • /
    • 2019
  • It is normal to observe the presence of numerous cracks in coal body. And it has significantly effective on the mechanical characteristics and realistic failure models of coal mass. Therefore, this paper is to investigate the influence of crack parameters on coal body by comprehensive using theoretical analysis, laboratory experiments and numerical simulation through prepared briquette specimens. Different from intact coal body possessing single peak in stress-strain curve, other specimens with crack angle can be illustrated to own double peaks. Moreover, the unconfined compressive strength (UCS) of specimens decreases and follow by increasing with the increase of crack angle. It seems to like a parabolic shape with an upward opening. And it can be demonstrated that the minimum UCS is obtained in crack angle $45^{\circ}$. In terms of failure types, it is interesting to note that there is a changing trend from tensile failure to tensile-shear mixing failure with tension dominant follow by shear dominant with the increase of crack angle. However, the changing characteristics of UCS and failure forms can be explained by elastic-plastic and fracture mechanics. Lastly, the results of numerical simulations are good consistent with the experimental results. It provides experimental and theoretical foundations to reveal fracture mechanism of coal body with non-penetrating single crack further.