• 제목/요약/키워드: Comprehensive vibration assessment program

검색결과 32건 처리시간 0.025초

APR1400 미국 설계인증을 위한 종합진동평가 심사서류 작성 방안 (Written Plan of CVAP Design Control Document for APR1400 U.S. Design Certification)

  • 고도영;김동학;박영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.102-105
    • /
    • 2014
  • In accordance with U.S. Nuclear Regulatory Commission regulatory guide(NRC RG) 1.20(Rev.3), we are writing a comprehensive vibration assessment program(CVAP) design control document(DCD) and a technical report for U.S. NRC design certification(DC) of an Advanced Power Reactor 1400(APR1400) nuclear power plant(NPP). CVAP of an APR1400 NPP for U.S. NRC DC is classified as a non-prototype category 1 type. Therefore, CVAP DCD of reactor vessel internals(RVI) and steam generator internals(SGI) consist of analysis and full inspection program. However, piping system of primary and secondary system will be described as measurement program.

  • PDF

APR1400 원자로 내부배럴집합체 상부판 구조응답해석 (Structural Response Analysis on Inner Barrel Assembly Top Plate of APR1400 Reactor Vessel)

  • 김규형;고도영;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.907-910
    • /
    • 2012
  • Since the inner barrel assembly of the Advanced Power Reactor 1400 reactor vessel is a new design feature introduced instead of CEA(control element assembly) shroud assembly, the inner barrel assembly can be a significant object of structural integrity assessment. This paper covers the structural responses of top plate, which is a component of the inner barrel assembly, against the deterministic hydraulic load induced by pump pulsation and the random hydraulic load induced by turbulence of coolant. The top plate responds to the deterministic hydraulic load more than to the random hydraulic load and shows enough structural integrity. The results of this paper will be important basis for the selection of instruments and measurement location.

  • PDF

APR+원전 최초 호기의 CVAP 수행에 대한 제언 (Proposal for CVAP of First Plant of APR+ NPP)

  • 김동학;고도영;김만원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2014
  • The comprehensive vibration assessment program(CVAP) of APR+ nuclear power plant(NPP) is classified as non-prototype, category II with Palo Verde NPP as valid prototype. In this paper, CVAP for first plant of APR+ NPP is proposed. The Control Element Assembly(CEA) shroud of APR+ NPP is different from that of Palo Verde NPP. And the Core Support Barrel(CSB) outer diameter and the flow rate of normal operation of APR+ NPP are larger than those of Palo Verde NPP. Vibration and stress analysis program should be conducted to establish test acceptance criteria. Limited vibration measurement program should be implemented to establish the margin of safety, demonstrate the satisfaction of test acceptance criteria and confirm the similar vibratory response between the APR+ and Palo Verde NPP. Because of the change of normal operation condition, the nominal differences between APR+ and Palo Verde NPP in the structural and hydraulic analysis are studied to determine the measurement locations.

  • PDF

APR1400 증기발생기 습분분리기 진동 특성에 관한 연구 (A Study on Vibration Characteristics of Moisture Separator for APR1400 Steam Generator)

  • 조민기;박태정;하창훈;박누가
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.99-101
    • /
    • 2014
  • A Comprehensive Vibration Assessment Program (CVAP) for steam generator internals (SGI) of Advanced Power Reactor 1400 (APR1400) is being performed in accordance with the United States Nuclear Regulatory Commission (U.S. NRC) Regulatory Guide 1.20 (RG 1.20) revision 3. This paper studies the vibration characteristics of moisture separator assembly as part of the vibration and stress analysis program for APR1400 SGI CVAP. The natural frequencies, mode shapes, and structural behavior of moisture separator assembly were investigated through modal analysis using finite element method and experimental measurement. Since the moisture separator consists of several items with complicated shape, an idealized shell model was used in the finite element analysis. Group of local modes caused by moisture separators and significant modes of shroud and separator support plate were identified. The results of this paper are to be utilized in the structural response analysis of moisture separator assembly.

  • PDF

APR1400 원자로내부구조물 종합진동평가 응답측정시험 허용기준 수립 (Establishment of Response Instrumentation Test Acceptance Criteria for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.212-218
    • /
    • 2011
  • APR1400 RVI CVAP using the non-prototype category is being conducted to verify integrity of the RVI design and to secure the CVAP technology. The measurement programs are to confirm vibration analysis results for reactor internals during preoperational and initial startup testing and to detemine the safety margin. One of the important basis for the measurement programs is test acceptance criteria. Therefore, this paper is on establishment of response instrumentation test acceptance criteria for APR1400 RVI CVAP. The established acceptance criteria show that the stress criteria of APR1400 RVI are more conservative values than those of the valid prototype plant(Palo Verde unit 1) and, the displacement criteria of the IBA and the UGS were established to 0.03 in and 0.01 in, respectively.

  • PDF

Structural Vibration of Cove Support Barrel Assembly for Yonggwang Nuclear Unit 4

  • Park, Suhn;Jung, Seung-Ho;Lee, Ki-Young
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.283-288
    • /
    • 1996
  • Core support barrel (CSB) assembly is one of the most important reactor internals structures supporting and protecting the nuclear core during normal operation and faulted events. For Yonggwang 3 and 4 (YGN 3&4), the adequacy of the analytical response prediction of reactor internals for flow induced vibration was demonstrated through the comprehensive vibration assessment program (CVAP) performed during hot functional test. Besides, the vibration characteristics of the CSB of operating nuclear power plant can be examined via the excore neutron noise monitoring signal. In this paper data from YGN 4 analyses, CVAP, and neutron noise monitoring system are compared and evaluated. In general, the results are comparable each other and conservative enough to ensure sufficient design margin and structural integrity. Further investigations on the modelling and analyses procedure are recommended to utilize the experimental results to the maximum extent. And collection of the neutron noise data is desired to serve as a baseline information.

  • PDF

Structural monitoring and identification of civil infrastructure in the United States

  • Nagarajaiah, Satish;Erazo, Kalil
    • Structural Monitoring and Maintenance
    • /
    • 제3권1호
    • /
    • pp.51-69
    • /
    • 2016
  • Monitoring the performance and estimating the remaining useful life of aging civil infrastructure in the United States has been identified as a major objective in the civil engineering community. Structural health monitoring has emerged as a central tool to fulfill this objective. This paper presents a review of the major structural monitoring programs that have been recently implemented in the United States, focusing on the integrity and performance assessment of large-scale structural systems. Applications where response data from a monitoring program have been used to detect and correct structural deficiencies are highlighted. These applications include (but are not limited to): i) Post-earthquake damage assessment of buildings and bridges; ii) Monitoring of cables vibration in cable-stayed bridges; iii) Evaluation of the effectiveness of technologies for retrofit and seismic protection, such as base isolation systems; and iv) Structural damage assessment of bridges after impact loads resulting from ship collisions. These and many other applications show that a structural health monitoring program is a powerful tool for structural damage and condition assessment, that can be used as part of a comprehensive decision-making process about possible actions that can be undertaken in a large-scale civil infrastructure system after potentially damaging events.

APR1400 상부안내구조물 집합체 구조해석 및 측정위치 (Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.306-311
    • /
    • 2012
  • A reactor vessel internals comprehensive vibration assessment program (RVI CVAP) of an advanced power reactor 1400 (APR1400) is being performed as a non-prototype category-2 type of reactor based on the US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure (UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly results show that meet the specified integrity levels of the design acceptance criteria. Also, the measuring locations are set by the analysis results of the UGS assembly and selection criteria of measuring locations prior to this study. These analysis results and measuring locations will be used as fundamental materials to design a measurement system for the APR1400 RVI CVAP.

  • PDF

APR1400 원자로내부구조물 종합진동평가 측정위치 선정기준 개발 (Development of Selection Criteria of Measuring Places for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.821-826
    • /
    • 2011
  • A basic concept for selection criteria of measuring places of RVI CVAP is to determine measuring places and sensors based on the results of the hydraulic and structural analysis for RVI CVAP in APR1400. In addition, there is the important selection criteria to determine measuring places for measurement of RVI CVAP ; the first is to choose measuring places according to U.S. NRC R.G. 1.20, the second is to select measuring places by RVI design review, the third is to option on the basis of measurement results of SYSTEM 80, the forth is to decide using review results on a design change of a reactor and the last is to determine using the review on the possibility of installation/removal of sensors and structures for the measurement. We developed selection criteria of measuring places for RVI CVAP in APR1400 and this will be directly applied to the measurement program for RVI CVAP.

  • PDF

VIBRATION AND STRESS ANALYSIS OF A UGS ASSEMBLY FOR THE APR1400 RVI CVAP

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.817-824
    • /
    • 2012
  • The most important component of a nuclear power plant is its nuclear reactor. Studies on the integrity of reactors have become an important part regarding the safety of a nuclear power plant. The US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20 presents a Comprehensive Vibration Assessment Program (CVAP) to be used to verify the structural integrity of the Reactor Vessel Internals (RVI) for flow-induced vibration prior to commercial operation. However, there are few published studies related to the RVI CVAP. We classified the Advanced Power Reactor 1400 (APR1400) RVI CVAP as a non-prototype category-2 reactor as part of an independent validation of its design. The aim of this paper is to present the results of structural response analyses of the Upper Guide Structure (UGS) assembly of the APR1400 reactor. These results show that the UGS and the Inner Barrel Assembly (IBA) meet the specified integrity levels of the design acceptance criteria. The vibration and stress analysis results in this paper will be used as basic information to select measurement locations of the vibration and stress for the APR1400 RVI CVAP.