• 제목/요약/키워드: Compost biofilter

검색결과 56건 처리시간 0.027초

Effect of Biofilter Operation Parameters on Dimethyl Disulfide Removal : Loading, Time, and Concentration

  • Arpacioglu, Bora C.;Kim, Jo-Chun;Allen, Eric R.;Kim, Seoung-Hyun
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.783-791
    • /
    • 2002
  • A laboratory-scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide(DMDS). The biofiltration of DMDS was found to depend on the pollutant loadings rather than the inlet concentrations. It was estimated that the pollutant was only inhibitory to the operation of the biofilters at DMDS concentrations greater than 5500 ppmv A residence time of 30 seconds(120 m$^3$/m$^2$/h volumetric loading) was determined as appropriate for efficient operation(>90%). The maximum elimination capacity for both compost mixtures under the current experimental conditions was found to range from 7.5 to 10 g-DMDS/m$^3$/h. A lower DMDS maximum elimination capacity was exhibited under acidified conditions.

Dimethyl Sulfide [DMS] 분해균주인 Gordonia sihwaniensis PKL-1의 생물학적 분해특성 (Biodegradation Characteristics of Dimethyl sulfide [DMS] by Isolated Gordonia sihwaniensis PKL-1)

  • 정인경;이일현;박창호
    • KSBB Journal
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2004
  • 휘발성 황화합물 중 생물학적으로 가장 난분해성으로 알려 져 있는 DMS에 대한 분해능이 우수한 신균주를 분리. 동정 하여 Gordonia sihwaniensis PKL-1로 명명하였다. 이 균주는 D DMS 초기농도가 35 mg/L 이상일 때에도 우수한 분해능을 보였고, 회분식 배양에서 최대 비분해속도 $\upsilon_{max}$ 없는 0.0016 mg/(mg-protein).hr이 었고, 최적 의 온도와 pH는 각각 $25^{\circ}C$ 와 pH는 7이였다.

교반식 축분 퇴비화 및 톱밥 탈취처리 시스템의 퇴비화 암모니아 제거 성능 (Performance Characteristics of Agitated Bed Manure Composting and Ammonia Removal from Composting Using Sawdust Biofiltration System)

  • 홍지형;박금주
    • 한국축산시설환경학회지
    • /
    • 제13권1호
    • /
    • pp.13-20
    • /
    • 2007
  • 퇴비화 목적은 축분을 오물감과 악취 없이 살균처리 하고, 토양과 작물에 무해한 유기성 자원의 순환이용이다. 퇴비화 호기성 미생물의 이분해성 유기물 (영양원: 탄질비)분해 적정조건은 수분, 공기, 온도, 퇴비화 기간 등이며, 퇴비화 부숙 목적은 이분해성 유기물분해 및 생육저해 물질분해 등에 있다. 부숙도 판정법은 퇴적물의 온도변화(이분해성유기물분해 검사) 및 발아시험(생육저해물질 검사)등이 바람직하다. 본 연구는 퇴비화 온도, 퇴비화 암모니아가스 농도와 악취물질의 탈취처리, 종자 발아율, 퇴비재료 성분 및 EC 농도 등의 퇴비화 부숙도 주요 요인에 대한 3회 반복 실험성과는 다음과 같다. 본 연구결과로서 퇴비화 주발효 및 후숙 6주간 전반기에서 이분해성 유기물 분해와 취기물질 제거에 관련된 퇴비화 온도, 암모니아 농도, 탄질비 및 염류농도, 후반기 후숙 기간에 작물생육저해물질 제거에 연관된 발아율과 탄산가스 발생량 등을 실측조사 분석한 결과는 다음과 같으며, 안정된 숙성 퇴비의 적정 범위를 유지하여 양질 퇴비 생산이 가능하였다. 1. 축사저류조의 돼지배설물의 고액분리 고형분과 착즙액 정화처리 잉여오니 및 톱밥혼합물의 퇴비화 온도가 $55\sim65^{\circ}C$를 2일 이상 유지하여 병원균과 잡초 종자를 사멸하고, 악취가 미미한 44ppm 이하수준의 비교적 낮은 암모니아농도 및 50% 내외의 저수분의 양질 퇴비 생산이 가능하였다. 2. 퇴비화 실험결과는 퇴비화 온도가 $55\sim65^{\circ}C$로서 1주간 이상, 퇴비재료 수분 50%, 종자 발아율 70% 이상 및 EC농도 5ds/m 이하 등의 수준을 유지하고 있어 완숙퇴비 조건을 구비하고 있었다.상관관계가 비교적 높았으나, 음수량과 분 배설량$(R^2=0.2950)$, 사료 섭취량과 뇨 배설량$(R^2=0.1985)$, 산유량과 뇨 배설량$(R^2=0.2335)$의 상관관계는 낮게 나타났다. 6. 따라서 산유량과 음수량, 산유량과 사료 섭취량의 상관관계식은 $Y=0.1919X_1+11.181(R^2=0.7742),\;Y=0.8568X_2+9.3067(R^2=0.7459)$(Y=milk yield $X_1=water$ consumption, $X_2=feed$ intake)로 추정할 수 있다.. 이상(以上)의 결과(結果)로서 통일(統一)벼가 일반품종(一般品種)에 비(比)하여 저장성(貯藏性)이 우수(優秀)함을 인정(認定)할수 있어 장기저장(長期貯藏)을 위(爲)한 미곡(米穀)으로 활용(活用)할 수 있는 가능성(可能性)을 암시(暗示)하고 있다.록 Lact. plantarum ATCC 8014, Lact. fermenti ATCC 9338균주(菌株)의 산생성(酸生成)을 촉진(促進)하는 경향(傾向)을 보였다.V또는 ara-A의 동시첨가는 GCV또는 ara-A를 단독으로 첨가했을 경우보다 단백질의 합성을 더욱 억제하였다. 이상의 실험결과로 보아 GCV와 ara-A의 동시사용은 HSV-1 혹은 ACV저항 DNA polymerase변이주인 $PAA^r5$에 대해서 상승적인 억제작용을 나타냈으며 이 효과는 virus DNA 합성 억제에 의한 것으로 생각된다. ACV저항 thymidine kinase 변이주인 $ACV^r$$IUdR^r$

  • PDF

돈사 악취 저감을 위한 바이오필터 개발 (Development of Biofilter for Reducing Offensive Odor from Pig House)

  • 이승주;임송수;장동일;장홍희
    • 한국환경농학회지
    • /
    • 제24권4호
    • /
    • pp.386-390
    • /
    • 2005
  • 국내에서 구입이 용이한 부숙수피와 펄라이트를 부피비 7:3으로 혼합하여 혼합충전재에 암모니아 산화균 Rhodococcus equi A3와 황 산화균 Alcaligenes sp. S5-5.2를 접종한 후, 개발한 양압식 상향류 방식의 바이오필터에 혼합충전재를 충전하여 돈사에서 발생하는 암모니아 및 황화수소에 대한 악취가스 제거성능을 실험을 실시하였다. 혼합충전재에 미생물을 접종한 후 72시간동안 순치하였을 때의 미생물 생균수와 24시간 간격으로 측정하였을 때의 미생물 생균수가 거의 같은 것으로 나타났다. 이는 개발한 바이오필터가 미생물의 생육조건을 유지하는데 성공했다고 판단된다. 또한 암모니아 가스의 유입농도는 평균 $22.8{\pm}5.2mgL^{-1}$이었고, 배출농도는 평균 $2.1{\pm}0.3mgL^{-1}$, 제거율은 90.8%이었다. 흐리고 황화수소의 유입농도는 평균 $2.7{\pm}1.2mgL^{-1}$이었고, 배출농도는 $0.5{\pm}0.2mgL^{-1}$, 제거율은 81.5%로 비교적 높았다. 이와 같이 부숙수피와 펄라이트를 혼합하여 만든 혼합충전재를 충전한 바이오필터가 악취가스 제거율이 비교적 높고 가격이 저렴한 것을 고려해 볼 때, 기존의 다른 충전재을 이용한 바이오필터보다 개발한 바이오필터가 양돈가에서 이용하는데 유리한 것으로 판단된다.

하이브리드시스템을 이용한 악취폐가스 처리 (Treatment of Malodorous Waste Air Using Hybrid System)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제48권3호
    • /
    • pp.382-390
    • /
    • 2010
  • 본 연구에서는 광촉매반응기/폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정으로 이루어진 하이브리드시스템을 구축하여 퇴비공장 또는 공공시설에서 발생되는 황화수소, 암모니아 및 휘발성 유기화합물을 포함한 악취폐가스에 대한 처리효율을 제고하고 종합적인 적정 작업조건을 구축하였다. 악취가스(2 L/min)에 포함된 암모니아(300 ppmv)의 경우 광촉매반응기에서 약 22%가 제거되고, 폐가스 가습조에서 약 55%가 제거되고, 후 공정인 바이오필터에서 나머지인 약 23%가 모두 제거되었다. 악취가스에 포함된 톨루엔(100 ppmv)의 경우 광촉매반응공정에서 약 20%가 제거되고, 폐가스 가습조(유동상 호기 및 무산소조)에서 약 10% 제거되며 마지막 공정인 바이오필터에서 나머지 70% 모두가 제거되었다. 따라서 물에 용해도가 높은 암모니아의 경우에는 폐가스가습조에서 주로 제거되었고, 용해도가 낮은 톨루엔의 경우는 바이오필터에서 주로 제거되었다. 한편 황화수소(10 ppmv)는 광촉매반응공정에서 거의 처리되고 잔류 trace는 폐가스가습조에 용해되어서 바이오필터로 인입되는 가습된 feed에서 황화수소가 검지되지 않았다. 폐가스 가습조(유동상호기 및 무산소조)에서의 nitrate 농도는 무산소조에서 발생하는 탈질반응 때문에 무산소조 경우가 유동상호기조보다 약 3 ppm 정도 낮았다. 또한 폐가스가습조의 용존 암모니아 농도는 실험 시작부터 1,500~2,000 ppm 사이의 높은 값을 유지하였는데, 이는 폐가스 가습조 내부에 있는 용수에 포함된 염화암모늄 및 기타 암모니아성 질소원에 기인한다고 간주된다.

생물탈취상에 의한 도시폐기물 매립지가스내 악취물질의 처리 (Biofiltration of Odorous Compounds in Municipal Solid Waste Landfill Gases)

  • 남궁완;박준석;황의영;이노섭;인병훈;김정대
    • 한국토양환경학회지
    • /
    • 제4권1호
    • /
    • pp.85-96
    • /
    • 1999
  • 퇴비를 충전물질로 사용한 생물탈취상으로 난지도매립지에서 발생되는 매립지가스 처리시 악취유발물질 및 휘발성 유기화합물의 제거특성과 생물탈취상의 적용가능성을 평가하고자 하였다 본 연구는 난지도매립지 상부에서 실시하였으며 충전물질로는 난지도퇴비화시범시설에서 생산된 퇴비를 사용하였다. 약 15ppmv로 유입된 황화수소는 25cm충전깊이에서도 98%이상 제거되었으며 산소공급중단 후 혐기성가스만 유입시에는 처리효율이 30%로 저하하였다. 평균유입농도 40ppmv에서의 암모니아 제거 효율은 85%정도이었다. BTEX중 톨루엔과 에틸벤젠의 제거효율은 80%로 벤젠과 자일렌보다 높았다. 수분손실은 가스유입구에서 가장 높게 나타났으며 약 30일 운전기간 동안 pH저하에 의한 산성화는 발생하지 않았다.

  • PDF

토양 혼합여재를 이용한 질소산화물 제거특성 (Removal Characteristics of NOx Using a Mixed Soil-Biofilter)

  • 조기철;신은상;황경철;조일형;이내현;여현구
    • 환경위생공학
    • /
    • 제21권3호
    • /
    • pp.15-26
    • /
    • 2006
  • As traffic in city-centre around the world continues to increase, so levels of atmospheric pollutants continue to rise. High concentrations of NOx can have negative effects on human health, and we must find new ways to reduce their levels in the air we breathe. Nitrogen oxide gas (NOx), consisting of nitrogen monoxide (NO) and nitrogen dioxide $(NO_2)$ produced using $O_3$ oxidation, at a low concentration corresponding to that on roads as a result of exhaust from automobiles, was carried out to evaluate the removal characteristics of NOx through a laboratory-scale biofilter packed with soil as a packing material. A mixture media (yellow soil (30%): soil (40%): compost (10%): a used briquet (20%)) was applied. After about 1day of operation, the removal efficiency for $NO_2$ in all experiments with a constant condition ($25^{\circ}C$ and water humidity (60%)) was over 98%. The retention times of the section between phase I and phase II for formation and reduction of $NO_3$ NO and $NO_2$ on the initial $NO_3$ concentration was 50min $(O_3:195\;ppb),\;55min\;(O_3:925\;ppb),\;65min\;(O_3:1743\;ppb),\;70min\;(O_3:2616\;ppb),\;75min\;(O_3:3500\;ppb)$, respectively The soil biofilter system is a unique technology that purifies urban air by utilizing the natural processes that take place in the soil. Although some of the processes are quite complex, they can broadly be summarized as adsorption onto soil particles, dissolution into soil pore water, and biochemical.

가솔린 휘발가스의 바이오필터 처리에 관한 동력학적 연구 (Kinetics of the Biofilter Treating Gasoline Vapor)

  • 박준석;남궁완
    • 유기물자원화
    • /
    • 제9권3호
    • /
    • pp.70-76
    • /
    • 2001
  • 바이오필터를 적절하게 설계하고 처리효율을 향상시키기 위해서는 바이오필터에서의 오염물질에 관한 동력학적 연구가 선행되어야 한다. 본 연구는 가솔린 휘발가스의 바이오필터 처리시 분해특성을 동력학적으로 평가하고자 수행되었다. 바이오필터 충전물질로는 퇴비를 사용하였으며, TPH 가스유입농도는 약 $300mg/m^3$에서 $7,000mg/m^3$로 하였다. 가스유입속도는 6m/hr와 15m/hr로 하였다. 6m/hr의 속도로 가스를 주입할 경우 $3,000mg/m^3$ 이하의 농도에서는 약 60%가 유입부분인 하층 25cm깊이에서 제거되었다. 가솔린 휘발가스의 제거특성은 1차 반응모델로 표현하기에 적합하였다. 농도와 가스유입속도별로 1차 반응속도상수(k)를 비교한 결과 전체적으로 6m/hr에서의 k값이 15m/hr일 때보다 높게 나타났다. $3,000mg/m^3$ 이상의 고농도에서는 6m/hr일 때의 k값(0.09/min)이 15m/hr일 때보다 2배 이상 높았다. 가스유입속도와 유입농도 그리고 1차반응속도상수 등을 검토한 결과 가솔린 휘발가스를 80% 이상제거하기 위해서는 100cm 충전높이에서 농도를 약 $2,000mg/m^3$ 이하로 주입하되 6m/hr의 가스유입속도를 유지시켜 주는 것이 필요하였다. 바이오필터 운전조건 중 가스속도를 통제하는 것이 가스농도를 통제하는 것보다 더 중요하다.

  • PDF

퇴비 및 폐타이어 Granule을 이용한 악취 제거 (Odor Removal by Using Compost and Granular Scrap Tires)

  • 정윤진
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.43-50
    • /
    • 1999
  • In spite of low energy requirement, and operation and construction cost, biofilters with soil beds have not been operated efficiently. Because of excess moisture in winter and rainy periods, saturated pores in the bed prevent passage and sorption of odorous compounds. Sometimes this results in septic conditions that release previously sorbed and oxidized sulfur. Therefore, an economical and effective alternative needs to be developed. The objectives of this study were to confirm applicability of the granular scrap tires with compost for treating odorous gas as well as to obtain optimum design parameters for proposed system. In lab-scaled test, multiple stage reactors had lower headloss than a single stage reactor and less headloss was occurred for the gas with higher moisture content. For practical purpose, pilot-scaled reactor was operated to remove odor from septic tank, manure and animal wastewater treatment plant and composting machine. According to the results of pilot scaled test, $H_2S$ can be always removed completely and ammonia/amine can be removed excellently when proper moisture content is provided. The results from lab and pilot test showed that granular scrap tire could be replaced with soil as supporting material for biofilter showed excellent drainage because of its ability to reject moisture.

  • PDF

폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리 (Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제56권1호
    • /
    • pp.85-95
    • /
    • 2018
  • 본 연구에서는 폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정으로 이루어진 바이오필터시스템을 구축하여, 돈사 및 계사 설비, 퇴비공장 또는 공공시설에서 발생되는 황화수소, 암모니아 및 휘발성 유기화합물을 포함한 악취폐가스에 대한 처리효율을 제고하고 적정 작업조건을 구축하였다. 복합 악취폐가스 처리실험에서, 암모니아 부하의 경우 폐가스 가습조에서 약 75%가 제거되고, 후 공정인 바이오필터에서 20%이상 제거되었다. 톨루엔 부하의 경우 폐가스 가습조에서 약 20%가 제거되고, 후공정인 바이오필터에서 70% 이상 제거되었다. 따라서 물에 용해도가 높은 암모니아의 경우에는 폐가스 가습조에서 주로 제거되었고, 용해도가 낮은 톨루엔의 경우는 바이오필터에서 주로 제거되었다. 한편 황화수소는 폐가스 가습조에서 거의 흡수되어 바이오필터에서 검출되지 않았다. 황화수소 및 톨루엔의 공급을 중단하였을 때에, 암모니아 부하는 폐가스 가습조에서 약 65%가 제거되고 후 공정인 바이오필터에서 나머지 약 35% 정도가 제거되어, 거의 100%의 암모니아 부하가 제거되었다. 폐가스 가습조에서는 암모니아 외에 톨루엔 및 황화수소의 부하가 추가된 복합 악취폐가스의 경우보다 약 10% 더 적게 암모니아가 제거되었는데, 이것은 탈질에 필요한 톨루엔과 같은 유기화합물의 공급 중단에 기인하였다. 바이오필터시스템의 feed가, 1)복합 악취폐가스일 때, 2)암모니아 폐가스일 때에; 기존 폐가스 가습조 용수에 yeast extract를 보충한 경우 또는 yeast extract를 첨가하지 않고 탄소원으로 glucose를 첨가한 경우, 각각의 경우에 폐가스 가습조에서 흡수되는 암모니아질소 흡수율은, 각각 약 0.28 mg/min, 약 0.23 mg/min 및 약 0.27 mg/min으로 산출되었다. 한편 각각의 무산소조에서 탈질율은 0.42 mg/min, 0.55 mg/min, 및 약 0.27 mg/min이었다. 또한 폐가스 가습조(유동상 호기조)의 bubble column 모델링에서 유동상 호기조 단위부피당 bubble의 비표면적(a)과 향상된 물질전달계수(E $K_y$)의 곱의 값은 0.12/hr로 평가되었다.