• 제목/요약/키워드: Composite wall

검색결과 564건 처리시간 0.028초

Research on hysteretic characteristics of EBIMFCW under different axial compression ratios

  • Li, Sheng-cai;Lin, Qiang
    • Earthquakes and Structures
    • /
    • 제22권5호
    • /
    • pp.461-473
    • /
    • 2022
  • Energy-saving block and invisible multiribbed frame composite wall (EBIMFCW) is an important shear wall, which is composed of energy-saving blocks, steel bars and concrete. This paper conducted seismic performance tests on six 1/2-scale EBIMFCW specimens, analyzed their failure process under horizontal reciprocating load, and studied the effect of axial compression ratio on the wall's hysteresis curve and skeleton curve, ductility, energy dissipation capacity, stiffness degradation, bearing capacity degradation. A formula for calculating the peak bearing capacity of such walls was proposed. Results showed that the EBIMFCW had experienced a long time deformation from cracking to failure and exhibited signs of failure. The three seismic fortification lines of the energy-saving block, internal multiribbed frame, and outer multiribbed frame sequentially played important roles. With the increase in axial compression ratio, the peak bearing capacity and ductility of the wall increased, whereas the initial stiffness decreased. The change in axial compression ratio had a small effect on the energy dissipation capacity of the wall. In the early stage of loading, the influence of axial compression ratio on wall stiffness and strength degradation was unremarkable. In the later stage of loading, the stiffness and strength degradation of walls with high axial compression ratio were low. The displacement ductility coefficients of the wall under vertical pressure were more than 3.0 indicating that this wall type has good deformation ability. The limit values of elastic displacement angle under weak earthquake and elastic-plastic displacement angle under strong earthquake of the EBIMFCW were1/800 and 1/80, respectively.

복합지반 굴착 시 기반암의 깊이와 절리경사에 따라 흙막이벽체에 작용하는 토압 (Earth Pressure on the Braced Wall in the Composite Ground Depending on the Depth and the Joint Dips of the Base Rocks under the Soil Strata)

  • 배상수;이상덕
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.41-53
    • /
    • 2016
  • 토사층 하부에 절리암반층이 존재하는 복합지반을 굴착하고 설치하는 흙막이 구조물의 안정성은 배면에 작용하는 토압에 의해 결정된다. 보통 복합지반에서는 암반층을 토사로 간주하고 암반층의 지반강도 정수를 적용하여 경험적으로 토압을 구하는데, 암반층의 불연속면을 고려하지 않기 때문에 대개 실제 작용 토압보다 작게 산정된다. 본 연구에서는 복합지반에서 토사층과 암반층의 구성비율 및 암반층의 절리경사에 따라 흙막이 벽체에 작용하는 토압의 크기와 분포형태를 규명고자 대형토조(높이 3.0m, 길이 3.0m 폭 0.5m)에서 축척 1/14.5로 2차원 대형 모형실험을 수행하고, 같은 조건으로 수치해석을 수행하였다. 실험지반은 토사층과 암반층의 분포비가 각각 65%:35%와 50%:50%가 되도록 조성하였고, 암반층의 절리는 굴착측으로 $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$ 각도로 구성하였다. 그 결과 흙막이 벽체에 작용하는 토압은 암반층 절리 경사각(J)이 커질수록 증가 하였으며, 암반층비율이 증가함에 따라 암반층에 작용하는 토압도 증가하였다. 암반층에 작용하는 토압은 암반층의 비가 50%(R50)이고, 암반층의 절리 경사각이 $60^{\circ}$일 때 가장 크게 발생하였다. 대형모형실험과 수치해석 결과를 바탕으로 임의 복합지반을 굴착할 때 발생하는 토압을, 최상단 버팀대토압과 최대토압 및 굴착하단을 꼭짓점으로 하는 사각형분포로 이상화하고, 암반층비율과 절리경사각도를 고려하여 토압을 구할 수 있는 토압식을 제안하였다.

변형경화형 시멘트 복합체의 인장성능에 따른 끼움벽의 내진성능 (Influence of Strain-Hardening Cement Composite's Tensile Properties on the Seismic Performance of Infill Walls)

  • 차준호;윤현도
    • 콘크리트학회논문집
    • /
    • 제24권1호
    • /
    • pp.3-14
    • /
    • 2012
  • 이 논문에서는 비내진상세 골조의 손상완화능력 향상을 위한 연구의 일환으로 변형경화형 시멘트 복합체 끼움벽의 내진성능을 실험적으로 평가하였다. SHCC의 인장변형능력 및 균열거동 특성이 끼움벽의 전단 거동에 미치는 영향을 구명하기위해 총 3개의 끼움벽 실험체를 제작하여 반복하중 하에서 실험을 실시하였다. 이 연구에서 사용된 시멘트 복합체의 종류는 콘크리트와 SHCC로 하였다. SHCC는 인장 특성에 따른 영향을 검토하기위해 PVA1.3%+PE0.2% 및 PVA0.75%+PE0.75%로 두 종류의 배합조건을 갖도록 계획하였다. 끼움벽의 균열손상 발생 부위를 중앙부로 유도하기위해 모든 끼움벽 실험체의 좌 우측면에 100 mm 깊이의 노치를 설치하였다. 실험 결과, SHCC 끼움벽의 경우 철근 콘크리트 끼움벽에 비해 우수한 균열제어성능을 나타냈으며, 최대하중 도달 시점에서의 층간변위 또한 높게 나타났다. 특히, 초기 경사균열 발생 이후에도 SHCC 내의 보강 섬유간 섬유가교작용에 기인하여 완만한 강성 저하 양상을 나타냈다. 게다가 끼움벽의 균열폭을 기준으로 손상 식별 단계를 분석한 결과, PIW-SHD 실험체가 PIW-SLD 실험체에 비해 약 3배에 해당하는 우수한 내진성능을 나타냈다. 또한 대각 보강근의 변형률 진전 양상을 비교한 결과, 우수한 균열분산 특성에 기인하여 철근에 집중되는 인장응력을 SHCC 매트릭스가 일정 부분 부담하는 것으로 나타났다.

전통주택의 다락에 관한 연구 - 전북지방을 중심으로 - (A Study on the Loft in Korean Traditional Houses - Focused on the Chun-Buk Province -)

  • 최인호
    • 한국주거학회논문집
    • /
    • 제8권2호
    • /
    • pp.1-15
    • /
    • 1997
  • This study is purpose to analyze and adjust structure and composition methodology for Loft of korean traditional houses and than studying correlation about housing plan, according to middle-story structure like Loft form housing architecture. The Loft is composited to level by condition of location, using a rise of stair by expanding of span by function. We can divide to condition of location flatland and slant. In the flatland case, Loft is so heating that the kitchen floor make a lowly and in the slant case, Loft is composited a part of wing using height attitude of floor when the house build type and ㅁ type. Through this study. the Loft is various form of this structural forming then is affect the house facade. The composite of wall is come with the existence of Loft and the wall divided by the lintel and wall line.

  • PDF

타설형 콘크리트 중단열 벽체의 요구성능 분석 (Performance Requirement of Cast-in-place Concrete with Sandwich Insulation)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

Nonlinear finite element modeling of steel-sheathed cold-formed steel shear walls

  • Borzoo, Shahin;Ghaderi, Seyed Rasoul Mir;Mohebi, Saeed;Rahimzadeh, Ali
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.79-89
    • /
    • 2016
  • Cold formed steel shear panel is one of the main components to bearing lateral load in low and mid-rise cold formed steel structures. This paper uses finite element analysis to evaluate the stiffness, strength and failure mode at cold formed steel shear panels whit steel sheathing and nonlinear connections that are under monotonic loading. Two finite element models based on two experimental model whit different failure modes is constructed and verified. It includes analytical studies that investigate the effects of studs and steel sheathing thickness changes, fasteners spacing at panel edges, one or two sides steel sheathing and height-width ratio of wall on the lateral load capacity. Dominant failure modes include buckling of steel sheet, local buckling in boundary studs and sheet unzipping in the bottom half of the wall.

조적채움벽의 면외보강에 관한 연구 (A study on out-of-plane strengthening of masonry-infilled wall)

  • 장혜숙;은희창
    • 산업기술연구
    • /
    • 제41권1호
    • /
    • pp.7-13
    • /
    • 2021
  • Fiber-reinforced polymer reinforcement or polyurea reinforcement techniques are applied to strengthen unreinforced masonry walls (UMWs). The out-of-plane reinforcing effect of sprayed glass fiber-reinforced polyurea (GFRPU), which is a composite elastomer made of polyurea and milled glass fibers on UMW, is experimentally verified. The out-of-plane strengths and ductile behaviors based on various coating shapes are compared in this study. An empirical formula to describe the degree of reinforcement on the out-of-plane strength of the UMW is derived based on the experimental results. It is reported that the peak load-carrying capacity, ductility, and energy absorption capacity gradually improve with an increase in the strengthening degree or area. Compared with the existing masonry wall reinforcement method, the GFRPU technique is a construction method that can help improve the safety performance along with ease of construction and economic efficiency.

Effect of Ni-Ti shape memory alloy on ductility and response modification factor of SPSW systems

  • Atefeh Khosravikhor;Majid Gholhaki;Omid Rezaifar;Ghasem Pachideh
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.353-365
    • /
    • 2023
  • Shape memory alloys (SMAs) have emerged as a novel functional material that is being increasingly applied in diverse fields including medical, aeronautical and structural engineering to be used in the active, passive and semi-active structural control devices. This paper is mainly aimed at evaluating the ductility and response modification factor of the steel plate shear wall (SPSW) frames with and without the Ni-Ti shape memory alloys. To this end, different configurations were utilized, in which the walls were used in the first, third, middle, and all stories. The models were numerically analyzed using OpenSees Software. The obtained results indicate that improving the shape memory properties of alloys can greatly enhance the ductility and response modification factor. Furthermore, the model whose first and third stories are equipped with the SMA shear wall was found to be 290% more ductile, with a greater response modification factor compared to the unequipped frame.

저온용 저장탱크의 보온계산을 위한 Sol-Air 온도에 관한 연구 (A Study of the Sol-Air Temperature for the Calculation of Insulation in Cryogenic Storage Tank)

  • 손병진;맹주성;홍성민
    • 대한설비공학회지:설비저널
    • /
    • 제14권2호
    • /
    • pp.98-107
    • /
    • 1985
  • In this thesis, the Sol-Air temperature distribution for the side-wall of a cylindrical cryogenic storage tank made of nonhomogenious composite layer was studied, in order to calculate the thermal load by Newton's cooling law, when the solar radiation was applied upon the side wall. In the analysis, the atmospheric slab was assumed to be horizontal and infinitely large, and the Sol -Air temperature, which was found by the Net- Radiation method considering the longwave radiation wi th surroundings, was used for boundary condition. Energy equation and boundary conditions were normalized by the defined reference- temperature, and solved. The solutions were developed by the Fourier cosine series. Then, the Sol-Air temperature distribution for the side-wall of LNG storage tank was calculated.

  • PDF

Seismic performance evaluation of steel moment frames with self-centering energy-dissipating coupled wall panels

  • Lu Sui;Hanheng Wu;Menglong Tao;Zhichao Jia;Tianhua Zhou
    • Steel and Composite Structures
    • /
    • 제47권5호
    • /
    • pp.663-677
    • /
    • 2023
  • The self-centering energy-dissipating coupled wall panels (SECWs) possess a dual capacity of resiliency and energy dissipation. Used in steel frames, the SECWs can localize the damage of structures and reduce residual drifts. Based on OpenSEES, the nonlinear models were established and validated by experimental results. The seismic design procedure of steel frame with SECW structures (SF-SECW) was proposed in accordance with four-level seismic fortification objectives. Nonlinear time-history response analyses were carried out to validate the reasonability of seismic design procedure for 6-story and 12-story structures. Results show that the inter-story drifts of designed structures are less than drift limits. According to incremental dynamic analyses (IDA), the fragility curves of mentioned-above structure models under different limit states were obtained. The results indicate that designed structures have good seismic performance and meet the seismic fortification objectives.