• Title/Summary/Keyword: Composite truss

Search Result 143, Processing Time 0.017 seconds

Analysis of rotational end restraint for cross-beams of railway through truss bridges

  • Siekierski, Wojciech
    • Steel and Composite Structures
    • /
    • v.35 no.1
    • /
    • pp.29-41
    • /
    • 2020
  • Cross-beams of modern through truss bridges are connected to truss chord at its nodes and between them. It results in variable rotational end restraint for cross-beams, thus variable bending moment distribution. This feature is captured in three-dimensional modelling of through truss bridge structure. However, for preliminary design or rapid assessment of service load effects such technique of analysis may not be available. So an analytical method of assessment of rotational end restraint for cross-beam of through truss bridges was worked out. Two cases - nodal cross-beam and inter-nodal cross-beam - were analyzed. Flexural and torsional stiffness of truss members, flexural stiffness of deck members and axial stiffness of wind bracing members in the vicinity of the analyzed cross-beam were taken into account. The provision for reduced stiffness of the X-type wind bracing was made. Finally, general formula for assessment of rotational end restraint was given. Rotational end restraints for cross-beams of three railway through truss bridges were assessed basing on the analytical method and the finite element method (three-dimensional beam-element modelling). Results of both methods show good agreement. The analytical method is able to reflect effects of some structural irregularities. On the basis of the obtained results the general values of rotational end restraint for nodal and inter-nodal cross-beams of railway through truss bridges were suggested.

An Experimental Study on the Fire Resistance of Composite Truss Beam (합성트러스 보의 내화성능에 관한 실험적 연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.135-141
    • /
    • 2009
  • The composite truss has been widely used for tall buildings and long-span structures in North America. As compared with other similar structures, it has merits such as reduction of construction period, low span/depth ratio, low dead weight and so on. It has the most effective trait for structures with long span of 12~18m. After collapse of WTC, the fire resistance behaviors of structures have been actively conducted under various fire conditions in several country. This study showed that the surface temperature of steel member in the composit truss beam was reached to $700^{\circ}C$ under the fire condition of a short time. Under the same condition, the temperature in concrete was within $200^{\circ}C$. The composit truss beam with 20mm bracing was collapsed by rapid deflection after about 3minutes. However, the beams with 25mm, 35mm, and 45mm bracing were not collapsed, even though those were reached to deflection standard of L/20 within 15minutes.

Analysis of Reduction Effect on Noise Discharge from Lightweight Soundproof Tunnels Installed with Lateral Sound-absorbing Panels (직각 흡음체 설치 경량방음터널의 토출소음 저감효과 분석)

  • Jeong, Young Do;Ahn, Dong-Wook;Noh, Myung-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • Most of the soundproof tunnels generate significant discharge noise through their inlets and outlets so that the length of the tunnel has been extended frequently than required to minimize the effect on such discharge noise. Thus, in this paper, we investigate reduction capability of discharge noise from the sound proof tunnel installed with lateral sound-absorbing panels on the partitioned truss members in the longitudinal direction of the tunnel. In conclusion, noise field analysis results shows that the sound proof tunnels with lateral sound-absorbing panels have an effect on discharge noise abatement and thereby tunnel's length reduction.

Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members (격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가)

  • Noh, Myung-Hyun;Ahn, Dong-Wook;Joo, Hyung-Joong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

Shear Behavior of Pyramidal Shear Connectors (피라미드형 전단연결재의 전단거동)

  • Lee, Kyeong-Dong;Han, Sang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.131-137
    • /
    • 2000
  • In order to evaluate the design shear strength of composite slabs with truss-shaped shear connectors(TSC), a series of push-out tests on several types of specimens was carried out. The test results for the two parameters of bearing area and solid angle of the connector were compared to obtain the design shear force of the truss-shaped connectors. The results obtained from this study are as follows: (1) The slip-coefficients of TSC ranges from 0.87 to 3.12(${\times}10^6kgf/cm$). (2) The slip stiffness and the shear strength of TSC with $60.6cm^2$ bearing area are greater than those with $14.6cm^2$. (3) For estimating the allowable shear force of TSC, a design equation that is based on the bearing strength of the connector is suggested. (4) The mean safety factors of the critical force and the ultimate force are 2.38 and 4.62. respectively.

  • PDF

Design of top concrete slabs of composite space trusses

  • El-Sheikh, Ahmed
    • Structural Engineering and Mechanics
    • /
    • v.7 no.3
    • /
    • pp.319-330
    • /
    • 1999
  • The design of composite space trusses is a demanding task that involves taking several decisions on the truss depth, number of panels, member configuration, number of chord layers and concrete slab thickness and grade. The focus in this paper is on the design of top concrete slabs of composite space trusses, and in particular their thickness. Several effects must be considered in the process of designing the slab before an optimum thickness can be chosen. These effects include the inplane forces arising from shear interaction with the steel sub-truss and the flexural. and sheer effects of direct lateral slab loading. They also include a constructional consideration that the thickness must allow for sufficient cover and adequate space for placing the reinforcement. The work presented in this paper shows that the structural requirements on the concrete slab thickness are in many cases insignificant compared with the constructional requirements.

Cost minimization of prestressed steel trusses considering shape and size variables

  • Aydin, Zekeriya;Cakir, Ebru
    • Steel and Composite Structures
    • /
    • v.19 no.1
    • /
    • pp.43-58
    • /
    • 2015
  • There are many studies on the optimization of steel trusses in literature; and, a large number of them include a shape optimization. However, only a few of these studies are focused on the prestressed steel trusses. Therefore, this paper aims to determine the amounts of the material and cost savings in steel plane trusses in the case of prestressing. A parallel-chord simply supported steel truss is handled as an example to evaluate the used approach. It is considered that prestressing tendon is settled under the bottom bar, between two end supports, using deviators. Cross-sections of the truss members and height of the truss are taken as the design variables. The prestress losses are calculated in two steps as instantaneous losses and time-dependent losses. Tension increment in prestressing tendon due to the external loads is also considered. A computer program based on genetic algorithm is developed to solve the optimization problem. The handled truss is optimized for different span lengths and different tendon eccentricities using the coded program. The effects of span length and eccentricity of tendon on prestressed truss optimization are investigated. The results of different solutions are compared with each other and those of the non-prestressed solution. It is concluded that the amounts of the material and the cost of a steel plane truss can be reduced up to 19.9% and 14.6%, respectively, by applying prestressing.

Behavior analysis of aerial tunnel maintenance truss platform with high tensile steel UL-700

  • Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • v.24 no.3
    • /
    • pp.383-391
    • /
    • 2017
  • The goal of this study is to investigate structural analysis and behaviors of an innovative aerial work platform truss frame whose ductility is improved by using high strength-steel UL-700. The present space truss frame can move or stop through tunnels for maintenance constructions by automatic facilities and workmanship within standardized limited building lines of tunnel. Most of all, this method overcomes problematic, which is to block cars during construction periods, seriously, of typical methods like as using truck and scaffolds for tunnel maintenance. According to evaluated appropriate design results of space truss frames of numerical examples by using a commercial MIDAS GEN program, it is verified that design parameters such as layered size, cross-sectional size, and steel material of the present space truss frame are determined to depend on characteristics such as lanes or shape of road tunnels.

Behavior analysis of aerial tunnel maintenance truss platform with high tensile steel UL-700

  • Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.513-521
    • /
    • 2017
  • The goal of this study is to investigate structural analysis and behaviors of an innovative aerial work platform truss frame whose ductility is improved by using high strength-steel UL-700. The present space truss frame can move or stop through tunnels for maintenance constructions by automatic facilities and workmanship within standardized limited building lines of tunnel. Most of all, this method overcomes problematic, which is to block cars during construction periods, seriously, of typical methods like as using truck and scaffolds for tunnel maintenance. According to evaluated appropriate design results of space truss frames of numerical examples by using a commercial MIDAS GEN program, it is verified that design parameters such as layered size, cross-sectional size, and steel material of the present space truss frame are determined to depend on characteristics such as lanes or shape of road tunnels.

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.