• 제목/요약/키워드: Composite tips

검색결과 22건 처리시간 0.018초

Assessment of the radiant emittance of damaged/contaminated dental light-curing tips by spectrophotometric methods

  • Abdulrahman A. Balhaddad;Isadora Garcia;Fabricio Collares;Cristopher M. Felix;Nisha Ganesh;Qoot Alkabashi;Ward Massei;Howard Strassler;Mary Anne Melo
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.55.1-55.12
    • /
    • 2020
  • Objectives: This study investigated the effects of physically damaged and resin-contaminated tips on radiant emittance, comparing them with new undamaged, non-contaminated tips using 3 pieces of spectrophotometric laboratory equipment. Materials and Methods: Nine tips with damage and/or resin contaminants from actual clinical situations were compared with a new tip without damage or contamination (control group). The radiant emittance was recorded using 3 spectrophotometric methods: a laboratory-grade thermopile, a laboratory-grade integrating sphere, and a portable light collector (checkMARC). Results: A significant difference between the laboratory-grade thermopile and the laboratory-grade integrating sphere was found when the radiant emittance values of the control or damaged/contaminated tips were investigated (p < 0.05), but both methods were comparable to checkMARC (p > 0.05). Regardless of the method used to quantify the light output, the mean radiant emittance values of the damaged/contaminated tips were significantly lower than those of the control (p < 0.05). The beam profile of the damaged/contaminated tips was less homogeneous than that of the control. Conclusions: Damaged/contaminated tips can reduce the radiant emittance output and the homogeneity of the beam, which may affect the energy delivered to composite restorations. The checkMARC spectrophotometer device can be used in dental offices, as it provided values close to those produced by a laboratory-grade integrated sphere spectrophotometer. Dentists should assess the radiant emittance of their light-curing units to ensure optimal curing in photoactivated, resin-based materials.

정량 주입(Pre-metered) 코팅 방식을 이용한 유기 트랜지스터 반도체 박막 제작 연구 (Organic Semiconducting Thin Films Fabricated by Using a Pre-metered Coating Method for Organic Thin Film Transistors)

  • 조찬연;전홍구;최진성;김윤기;임종선;정준영;조성윤;이창진;박병주
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.531-536
    • /
    • 2012
  • We herein present results of flat and uniform polymer-blended small molecular semiconductor thin films. Which were produced for organic thin film transistors (OTFTs), using a simple pre-metered horizontal dipping process. The organic semiconducting thin films were composed of 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-PEN) composite blended with a polymer binder of poly(${\alpha}$-methylstyrene) (PaMS). We show that the pre-metered horizontal-dip-coating(H-dip-coating) process allowed the critical control of the thickness of the blended TIPS-PEN:PaMs thin film. The fabricated OTFTs using the TIPS-PEN:PaMs films exhibited maximum field-effect mobility of $0.22\;cm^2\;V^{-1}\;s^{-1}$. These results demonstrated that H-dip-coated TIPS-PEN:PaMS films show considerable promise for the production of reliable, reproducible, and high-performance OTFTs.

Two collinear Mode-I cracks in piezoelectric/piezomagnetic materials

  • Zhou, Zhen-Gong;Wang, Jia-Zhi;Wu, Lin-Zhi
    • Structural Engineering and Mechanics
    • /
    • 제29권1호
    • /
    • pp.55-75
    • /
    • 2008
  • In this paper, the behavior of two collinear Mode-I cracks in piezoelectric/piezomagnetic materials subjected to a uniform tension loading was investigated by the generalized Almansi's theorem. Through the Fourier transform, the problem can be solved with the help of two pairs of triple integral equations, in which the unknown variables were the jumps of displacements across the crack surfaces. To solve the triple integral equations, the jumps of displacements across the crack surfaces were directly expanded as a series of Jacobi polynomials to obtain the relations among the electric displacement intensity factors, the magnetic flux intensity factors and the stress intensity factors at the crack tips. The interaction of two collinear cracks was also discussed in the present paper.

비틀림하의 복합원통에 있는 원주 표면균열에 대한 응력 확대 계수

  • 김영종
    • 한국정밀공학회지
    • /
    • 제17권9호
    • /
    • pp.151-157
    • /
    • 2000
  • Stress intensity factors for the circumferential surface crack of a long composite cylinder under torsion is investigated. The problem is formulated as a singular integral equation of the first kind with a Cauchy type kernel using the integral transform technique. The mode III stress intensity factors at the crack tips are presented when (a) the inner crack tip is away from the interface and (b) the inner crack tip is at the interface.

  • PDF

Time effect of pile-soil-geogrid-cushion interaction of rigid pile composite foundations under high-speed railway embankments

  • Wang, Changdan;Zhou, Shunhua;Wang, Binglong;Guo, Peijun
    • Geomechanics and Engineering
    • /
    • 제16권6호
    • /
    • pp.589-597
    • /
    • 2018
  • Centrifuge model tests were used to simulate pile-raft composite foundation and pile-geogrid composite foundation with different pile spacing for researching the time effect of negative skin friction of rigid piles in high-speed railways. The research results show that the negative skin friction has a significant impact on the bearing capacity of composite foundation. Pile-raft composite foundation has higher bearing capacity compared to pile-geogrid composite foundation to reduce the effect of negative skin friction on piles. Both the foundation settlement and negative skin friction have significant time effect. The distribution of skin friction can be simplified as a triangle along the pile. The neutral point position moves deeper in the postconstruction stage at larger pile spacing. For pile-geogrid composite foundation, the setting of pile-cap affects the position of neutral point in the post-construction stage. Reinforced cushion with geotextile may promote the better performance of cushion for transmitting the loads to piles and surrounding soils. Arching effect in the cushion of the composite foundation is a progressive process. The compression of the rigid piles contributes less than 20% to 25% of the total settlement while the penetration of the piles and the compression of the bearing stratum below the pile tips contribute more than 70% of the total settlement. Some effective measures to reduce the settlement of soils need to be taken into consideration to improve the bearing capacity of pile foundation.

Epoxylite Influence on Field Electron Emission Properties of Tungsten and Carbon Fiber Tips

  • Alnawasreh, Shady S;Al-Qudah, Ala'a M;Madanat, Mazen A;Bani Ali, Emad S;Almasri, Ayman M;Mousa, Marwan S
    • Applied Microscopy
    • /
    • 제46권4호
    • /
    • pp.227-237
    • /
    • 2016
  • This investigation deals with the process of field electron emission from composite microemitters. Tested emitters consisted of a tungsten or carbon-fiber core, coated with a dielectric material. Two coating materials were used: (1) Clark Electromedical Instruments Epoxylite resin and (2) Epidian 6 Epoxy resin (based on bisphenol A). Various properties of these emitters were measured, including the current-voltage characteristics, which are presented as Fowler-Nordheim plots, and the corresponding electron emission images. A field electron microscope with a tip (cathode) to screen (anode) distance of 10 mm was used to electrically characterize the emitters. Measurements were carried out under ultra-high vacuum conditions with a base pressure of $10^{-6}$ Pascal ($10^{-8}$ mbar).

4급 와동의 직접 레진 수복의 과정 (Clinical Practice of Class IV Direct Compoiste Resin Restoration)

  • 장희선
    • 대한심미치과학회지
    • /
    • 제27권1호
    • /
    • pp.18-23
    • /
    • 2018
  • 심미와 최소침습개념이 대중화되면서 파절된 치아의 치료에서 직접레진수복에 대한 요구도가 커지고 있습니다. 그러나 아직까지도 많은 치과의사들이 전치부에서 직접레진수복을 꺼려하며, 간접수복을 선호합니다. 이 글은 4급와동 수복의 각 단계에 대해 설명하고자 합니다. 전치부에서 심미적인 결과를 얻기 위해서는 적층충전이 필수적이며, 이 글에 서는 임상에 유용한 팁들을 소개하겠습니다.

고구마 끝순 및 괴근의 안토시아니딘 추출 조건 최적화 (Optimization of anthocyanidin extraction conditions from sweet potato tips and tuber)

  • 홍채영;서정현;김민영;이윤정;윤향식;남상식;이준수;정헌상
    • 한국식품과학회지
    • /
    • 제52권3호
    • /
    • pp.290-295
    • /
    • 2020
  • 본 연구에서는 고구마 끝순과 괴근으로부터 자색색소인 안토시아니딘을 추출하기 위한 최적조건을 확립하였다. 에탄올 농도(10-90%), citric acid 농도(0.1-0.5%) 그리고 추출온도(30-70℃)를 변수로 중심합성계획법으로 설계하고 반응표면분석법으로 최적화 하였다. 세가지 변수 모두 안토시아니딘 추출에 유의적인 영향을 주었으며, 산 농도나 추출 온도보다는 에탄올 농도의 영향력이 컸다. 각각의 추출조건 중 에탄올 농도 50%, citric acid 농도 0.3%, 추출 온도 50℃에서 끝순은 26.58±0.07 mg/100 g을 나타내었고 괴근은 117.32±0.39 mg/100 g으로 가장 높았다. 반응표면분석에 의한 최적추출조건은 끝순은 에탄올 농도 56.10%, citric acid 농도 0.25% 그리고 추출 온도 52.24℃이었으며, 괴근은 각각 55.08, 0.30, 53.06℃이었다. 최적추출조건에서의 예측값은 각각 27.45, 119.61 mg/100 g이었으며, 실측값은 각각 27.09±0.11, 118.72±0.67 mg/100 g이었다. 예측값과 비교할 때 각각 98.69, 99.26%로 나타나 추출조건의 유효성이 확인되었다.

논문 : 복합재료 항공기 동체 부품 설계 (Papers : Component Design of a composite Aircraft Fuselage)

  • 김성열;이수용;박정선
    • 한국항공우주학회지
    • /
    • 제30권1호
    • /
    • pp.65-74
    • /
    • 2002
  • 항공기 동체의 주 구조를 이루는 스킨, 스트링거, 프레임을 복합재료 부재료 대체하여 파손 및 좌굴에 대해 유한요소해석을 수행하였다. 각 부재의 하중은 기존 항공기 MD90-30의 하중을 적용하였으며, 스트링거, 프레임은 I, Z, T-type의 3가지 단면형상을 선정하여 해석하였다. 복합재료 부재의 적층각, 적층수에 따른 부재의 특성을 알아보고, 단면형상에 대한 비교를 수행하였다. 해석결과 파손은 적층각에 좌굴은 적층수에 많은 영향을 받으며, 스킨, 스트링거는 좌굴이 프레임은 축방향 하중에 의한 파손이 부재 설계의 중요한 요소임을 알 수 있었다. 스트링거, 프레임은 준등방성 적층의 경우 [0/60/-60]적층이 좋은 결과를 갖는 것을 알 수 있었고 단면형상에 대해서는 I-type이 가장 좋은 결과를 보였다. 또한 기존 알루미늄 부재와의 비교를 통해 복합재료 부재의 경량성을 확인할 수 있었다.

유전치 심미수복치료를 위한 임상적 고려 (A clinical consideration of the esthetic restorations for treatment of primary anterior teeth)

  • 현홍근
    • 대한치과의사협회지
    • /
    • 제49권1호
    • /
    • pp.33-37
    • /
    • 2011
  • The esthetic demands are growing in treatment of primary maxillary incisors as well as permanent ones. There is something dissatisfying about in the keen eyes of the pediatric dentists on their esthetic results of efforts because current tooth color system is created for the purpose of the application to the permanent incisors. In this study using the scientific color measurement device, I would like to introduce a color scheme for the primary maxillary incisors and suggest clinical tips for the better results of resin composite restorations.