• 제목/요약/키워드: Composite columns

검색결과 731건 처리시간 0.02초

도로상 부구조물(교통표지판 및 가로등 지주)의 설계여정 (Odyssey for the Standard Design of Highway Minor Structures (Cantilever Columns for Signs, Luminaries, Traffic Signals))

  • 조태준;김명한;지효선
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.62-68
    • /
    • 2015
  • As a preparation of a design standard regarding road facilities, such as cantilever columns for traffic lights, street lights on highways is proposed. Currently these minor structures are designed based on guidelines which are mixed with multiple old foreign specifications without any criteria in terms of safety and economy, which could lead irregular safeties and the loss of national properties. In the considered two cases for effective projected area, it is found that following efficient way of design without critical analyses could make significant errors and miscalculations. Therefore, a fundamental research on the minor structures is urgently needed.

Displacement-based seismic design of reinforced concrete columns strengthened by FRP jackets using a nonlinear flexural model

  • Cho, Chang-Geun;Yun, Hee-Cheon;Kim, Yun-Yong
    • Computers and Concrete
    • /
    • 제6권2호
    • /
    • pp.95-108
    • /
    • 2009
  • In the current research, a displacement-based seismic design scheme to retrofit reinforced concrete columns using FRP composite materials has been proposed. An accurate prediction for the nonlinear flexural analysis of FRP jacketed concrete members has been presented under multiaxial constitutive laws of concrete and composite materials. Through modification of the displacement coefficient method (DCM) and the direct displacement-based design method (DDM) of reinforced concrete structures, two algorithms for a performance-based seismic retrofit design of reinforced concrete columns with a FRP jacket have been newly introduced. From applications to retrofit design it is known that two methods are easy to apply in retrofit design and the DCM procedure underestimates the target displacement to compare with the DDM procedure.

Structural behavior of CFRP strengthened concrete-filled steel tubes columns under axial compression loads

  • Park, Jai Woo;Choi, Sung Mo
    • Steel and Composite Structures
    • /
    • 제14권5호
    • /
    • pp.453-472
    • /
    • 2013
  • This paper presents the structural behavior of CFRP (carbon fiber reinforced polymer) strengthened CFT (concrete-filled steel tubes) columns under axial loads. Circular and square specimens were selected to investigate the retrofitting effects of CFRP sheet on CFT columns. Test parameters are cross section of CFT, D/t (B/t) ratios, and the number of CFRP layers. The load and ductility capacities were evaluated for each specimen. Structural behavior comparisons of circular and rectangular section will be represented in the experimental result discussion section. Finally, ultimate load formula of CFRP strengthened CFT will be proposed to calculate the ultimate strength of CFRP strengthened circular CFT. The prediction values are in good agreement with the test results obtained in this study and in the literature.

Behavior of gusset plate-T0-CCFT connections with different configurations

  • Hassan, M.M.;Ramadan, H.M.;Naeem, M.;Mourad, S.A.
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.735-751
    • /
    • 2014
  • Concrete-filled steel tube (CFT) composite columns, either circular (CCFT) or rectangular (RCFT), have many economical and aesthetic advantages but the behavior of their connections are complicated. This study aims to investigate, through an experimental program, the performance and behavior of different connections configurations between circular concrete filled steel tube columns (CCFT) and gusset plates subjected to shear and axial compression loadings. The study included seventeen connection subassemblies consisting of a fixed length steel tube and gusset plate connected to the tube end with different details tested under half cyclic loading. A notable effect was observed on the behavior of the connections due to its detailing changes with respect to capacity, failure mode, ductility, and stress distribution.

복합판으로 보강된 철근콘크리트 기둥의 내진성능연구 (Earthquake-Resistant Capacity of RC Columns Retrofitted by Fiber-Steel Composite Plate)

  • 박태만;박성민;홍혁준;강경수;윤정배
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.113-120
    • /
    • 2005
  • 본 연구의 목적은 기둥의 내진성능을 개선하기 위한 연구로서, 섬유-강판이 복합된 보강재를 사용하여 보강기둥의 내력특성을 연구하였다. 이용 가능한 복합판의 보강량을 선정하고, 기존의 탄소섬유와 강판으로 보강한 기둥과 함께 밴드형 보강실험체를 제작하여 일정축력을 받는 기둥에 반복횡하중을 가하여 하중, 변의 및 연성도를 조사하였다. 내진성능의 척도가 되는 변위연성도, 에너지연성도, 누적소산에너지 및 감쇠비를 비교하여 복합판을 사용한 부재의 내력특성을 평가하였다. 연구결과, 복합판을 사용하여 기둥을 보강할 경우에도 다른 보강방법과 같이 양호한 내진성능을 확보할 수 있었다. 또한, 밴드형식으로 보강한 보강실험체의 연성능력은 모두 양호한 편이나, 최대하중 증가를 위해서는 일정량 이상의 보강량이 필요한 것으로 나타났다. 연성도 평가로는 에너지연성도가 변위연성도에 비하여 보강기둥의 연성능력을 잘 나타내었다.

Axial behavior of RC columns strengthened with SCC filled square steel tubes

  • Lu, Yi-Yan;Liang, Hong-Jun;Li, Shan;Li, Na
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.623-639
    • /
    • 2015
  • Self-compacting Concrete (SCC) Filled Square steel Tubes (SCFST) was used to strengthen square RC columns. To establish the efficiency of this strengthening method, 17 columns were tested under axial compression loading including 3 RC columns without any strengthening (WRC), 1 RC column strengthened with concrete jacket (CRC), 13 RC columns strengthened with self-compacting concrete filled square steel tubes (SRC). The experimental results showed that the use of SCFST is interesting since the ductility and the bearing capacity of the RC columns are greatly improved. The improvement ratio is significantly affected by the nominal wall thickness of steel tubes (t), the strength grade of strengthening concrete (C), and the length-to-width ratio (L / B) of the specimens. In order to quantitatively analyze the effect of these test parameters on axial loading behavior of the SRC columns, three performance indices, enhancement ratio (ER), ductility index (DI), and confinement ratio (CR), were used. The strength of the SRC columns obtained from the experiments was then employed to verify the proposed mode referring to the relevant codes. It was found that codes DBJ13-51 could relatively predict the strength of the SRC columns accurately, and codes AIJ and BS5400 were relatively conservative.

Behaviors of concrete filled square steel tubes confined by carbon fiber sheets (CFS) under compression and cyclic loads

  • Park, Jai Woo;Hong, Young Kyun;Choi, Sung Mo
    • Steel and Composite Structures
    • /
    • 제10권2호
    • /
    • pp.187-205
    • /
    • 2010
  • The existing CFT columns present the deterioration in confining effect after the yield of steel tube, local buckling and the deterioration in load capacity. If lateral load such as earthquake load is applied to CFT columns, strong shearing force and moment are generated at the lower part of the columns and local buckling appears at the column. In this study, axial compression test and beam-column test were conducted for existing CFT square column specimens and those reinforced with carbon fiber sheets (CFS). The variables for axial compression test were width-thickness ratio and the number of CFS layers and those for beamcolumn test were concrete strength and the number of CFS layers. The results of the compression test showed that local buckling was delayed and maximum load capacity improved slightly as the number of layers increased. The specimens' ductility capacity improved due to the additional confinement by carbon fiber sheets which delayed local buckling. In the beam-column test, maximum load capacity improved slightly as the number of CFS layers increased. However, ductility capacity improved greatly as the increased number of CFS layers delayed the local buckling at the lower part of the columns. It was observed that the CFT structure reinforced with carbon fiber sheets controlled the local buckling at columns and thus improved seismic performance. Consequently, it was deduced that the confinement of CFT columns by carbon fiber sheets suggested in this study would be widely used for reinforcing CFT columns.

BFRP 보강이 직사각형 단면 철근콘크리트 기둥의 지진거동에 미치는 영향 (Effect of BFRP Wrapping on Seismic Behavior of Rectangular RC Columns)

  • 이혜린;조정현;이승건;이수형;홍기증
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.153-160
    • /
    • 2020
  • 지진동 하의 구조 시스템에서 기둥은 가장 중요한 구조 요소 중 하나이다. 이러한 관계로, 철근콘크리트(RC) 기둥의 내진 성능에 FRP 보강이 미치는 영행을 평가하기 위하여 광범위한 실험 연구가 이루어졌다. 이 중 상당수는 CFRP 또는 GFRP로 보강된 원형 단면 또는 정사각형 단면의 RC 기둥의 지진 거동에 집중하였다. 단면의 형태가 FRP 보강으로 인한 구속 효과에 영향을 미치기 때문에, 보강 효과와 최종 파괴 패턴이 형상에 따라 상이할 수 있다. 본 연구에서는 현무암 섬유를 함유한 BFRP 시트와 복합섬유 패널로 보강한 직사각형 단면을 가진 RC 기둥의 지진 거동을 살펴보기 위하여 반복하중 실험을 수행하였다. 실험 결과는 보강 효과가 크지 않았음을 보여주는데, BFRP 시트와 복합섬유 패널에 의한 구속 효과의 증가가 미미했음을 의미하며, 이는 기둥 단면 형상에 일부 기인하는 것으로 판단된다.

Seismic behavior of circular-in-square concrete-filled high-strength double skin steel tubular stub columns with out-of-code B/t ratios

  • Jian-Tao Wang;Yue Wei;Juan Wang;Yu-Wei Li;Qing Sun
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.441-456
    • /
    • 2023
  • Aiming at the development trend of light weight and high strength of engineering structures, this paper experimentally investigated the seismic performance of circular-in-square high-strength concrete-filled double skin steel tubular (HCFDST) stub columns with out-of-code width-to-thickness (B/t) ratios. Typical failure mode of HCFDST stub columns appeared with the infill material crushing, steel fracture and local buckling of outer tubes as well as the inner buckling of inner tubes. Subsequently, the detailed analysis on hysteretic curves, skeleton curves and ductility, energy dissipation, stiffness degradation and lateral force reduction was conducted to reflect the influences of hollow ratios, axial compression ratios and infill types, e.g., increasing hollow ratio from 0.54 to 0.68 and 0.82 made a slight effect on bearing capacity compared to the ductility coefficients; the higher axial compression ratio (e.g., 0.3 versus 0.1) significantly reduced the average bearing capacity and ductility; the HCFDST column SCFST-6 filled with concrete obviously displayed the larger initial secant stiffness with a percentage 34.20% than the column SCFST-2 using engineered cementitious composite (ECC); increasing hollow ratios, axial compression ratios could accelerate the drop speed of stiffness degradation. The out-of-code HCFDST stub columns with reasonable design could behave favorable hysteretic performance. A theoretical model considering the tensile strength effect of ECC was thereafter established and verified to predict the moment-resisting capacity of HCFDST columns using ECC. The reported research on circular-in-square HCFDST stub columns can provide significant references to the structural application and design.

Modelling of recycled aggregate concrete-filled steel tube (RACFST) beam-columns subjected to cyclic loading

  • Yang, You-Fu
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.213-233
    • /
    • 2015
  • A nonlinear finite element analysis (FEA) model is presented for simulating the behaviour of recycled aggregate concrete-filled steel tube (RACFST) beam-columns subjected to constant axial compressive load and cyclically increasing flexural loading. The FEA model was developed based on ABAQUS software package and a displacement-based approach was used. The proposed engineering stress versus engineering strain relationship of core concrete with the effect of recycled coarse aggregate (RCA) replacement ratio was adopted in the FEA model. The predicted results of the FEA model were compared with the experimental results of several RACFST as well as the corresponding concrete-filled steel tube (CFST) beam-columns under cyclic loading reported in the literature. The comparison results indicated that the proposed FEA model was capable of predicting the load versus deformation relationship, lateral bearing capacity and failure pattern of RACFST beam-columns with an acceptable accuracy. A parametric study was further carried out to investigate the effect of typical parameters on the mechanism of RACFST beam-columns subjected to cyclic loading.