• Title/Summary/Keyword: Composite Power Systems

Search Result 152, Processing Time 0.031 seconds

Evaluation of the Reliability of Distribution Power Systems Considering Composite Customer Interruption Cost

  • Choi Sang-Bong;Nam Kee-Young;Kim Dae-Kyeong;Jeong Seong-Hwan;Lee Jae-Duk;Ryoo Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.286-292
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that consider the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

Evaluation of the Interruption Cost of Distribution Power Systems Considering the Failure Source and the Composite Customer Interruption Cost

  • Park, Sang-Bong;Nam, Kee-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.124-129
    • /
    • 2003
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that take into account the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

A Study on the calculation of LSC in composite power systems (복합전력개통의 최대전력 수송능력 산정에 관한 연구)

  • Kook, K.S.;NamKung, J.Y.;Lee, B.J.;Song, K.Y.;Cha, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.775-777
    • /
    • 1997
  • This paper presents an algorithm for the calculation of LSC(Load Supplying Capability) in composite power systems. LSC means the maximum load which the composite power system can supply under the constraints of interest and power flow equations. In this paper, Successive Linear Programming algorithm is used to calculate the LSC of composite power systems. This algorithm is applied to the Six-Bus system and IEEE RTS.

  • PDF

Characteristices of Composite Hollow Insulator for 170 kV GIS (170 kV GIS용 Composite Hollow Insulator 특성 평가)

  • Jang, Yoon-Ki;Jung, Young-Soo;Lee, Dong-Woen
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1534-1535
    • /
    • 2011
  • Composite hollow insulator consist of an insulating tube bearing the mechanical load protected by an elastomer housing the loads being transmitted to the tube by metal fittings. The core processes are comprised briefly and the electrical and mechanical performance were examined according to the IEC standards. In this study, we have manufactured the composite hollow insulator, and carry out the insulator and busing type test according to the IEC standards. Comprehensive approach followed by the test results would give feasible hollow composite insulator compliable to the IEC standards.

  • PDF

Fuzzy-GA Application for Allocation and Operation of Dispersed Generation Systems in Composite Distribution Systems (복합배전계통에서 분산형전원의 설치 및 운영을 위한 Fuzzy-GA 응용)

  • 김규호;이유정;이상봉;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.584-592
    • /
    • 2003
  • This paper presents a fuzzy-GA method for the allocation and operation of dispersed generator systems(DGs) based on load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The problem formulation considers an objective to reduce power loss of distribution systems and the constraints such as the number or total capacity of DGs and the deviation of the bus voltage. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 12 bus and 33 bus test systems to demonstrate its effectiveness. .

Development of a Program for Reliability and Probabilistic Production Cost Evaluation of Composite Power Systems using GUI (GUI를 이용한 복합전력계통의 신뢰도해석 및 확률론적 발전비산정 프로그램 개발)

  • Moon, Seung-Pil;Kim, Hong-Sik;Cha, Jun-Min;Rho, Dae-Seok;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.243-245
    • /
    • 2001
  • The reliability and probabilistic generation production cost evaluation of composite power systems are important for power system operation and expansion planning. This paper present a computer program which can evaluate the reliability and probabilistic generation production cost of composite power system using GUI(Graphic User Interface). In this computer program, Monte Carlo simulation methods and CMELDC(CoMposite power system Effective Load Duration Curve) were used.

  • PDF

Characteristics of Shield Materials for Wireless Power Transfer

  • Chu, In Chang;Jeong, Jinseong
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.291-294
    • /
    • 2014
  • In this paper, we examine the electrical and magnetic properties of three different types of shield materials used for wireless power transfer systems: namely, FeSiAl-composite, NiZn-ferrite, and FeSi-amorphous types. The power transfer efficiency and resistance of an RX coil are measured, while varying the shield thickness. For all three types, a thicker shield provides better power transfer efficiency. Analysis of the measurements shows that the FeSiAl-composite type is suitable for systems with size limitation. In terms of magnetic properties, the FeSi-amorphous type shows the best features, and is suited to high power applications. This work can be used as a guideline to select suitable shielding material in various wireless power transfer systems.

Development of Composite Load Models of Power Systems using On-line Measurement Data

  • Choi Byoung-Kon;Chiang Hsiao Dong;Li Yinhong;Chen Yung Tien;Huang Der Hua;Lauby Mark G.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.161-169
    • /
    • 2006
  • Load representation has a significant impact on power system analysis and control results. In this paper, composite load models are developed based on on-line measurement data from a practical power system. Three types of static-dynamic load models are derived: general ZIP-induction motor model, Exponential-induction motor model and Z-induction motor model. For the dynamic induction motor model, two different third-order induction motor models are studied. The performances in modeling real and reactive power behaviors by composite load models are compared with other dynamic load models in terms of relative mismatch error. In addition, numerical consideration of ill-conditioned parameters is addressed based on trajectory sensitivity. Numerical studies indicate that the developed composite load models can accurately capture the dynamic behaviors of loads during disturbance.

A Composite Camera Calibration Technique for Thermal Deterioration Diagnosis of Power Distribution Line (배전 선로의 열화 진단을 위한 복합 카메라 보정기법)

  • Jung, Ha-Hyoung;Park, Jin-ha;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a composite camera calibration method to determine thermal degradation of power distribution equipment by combining an infrared (IR) camera and a color camera. A calibration jig was first constructed to match the properties of the two cameras. Our calibration and visualization techniques allow for the display of two images, one from the color camera and the other from the IR camera with different field of views (FOVs), on the screen at the same time. To confirm its validity, several case studies have been developed to analyze thermal deterioration limits of indoor and outdoor power distribution facilities.

Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP (EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석)

  • Jung, Chae-Kyun;Jang, Tai-In;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.