• Title/Summary/Keyword: Composite Power System

Search Result 309, Processing Time 0.031 seconds

Mitigation of Negative Impedance Instabilities in a DC/DC Buck-Boost Converter with Composite Load

  • Singh, Suresh;Rathore, Nupur;Fulwani, Deepak
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1046-1055
    • /
    • 2016
  • A controller to mitigate the destabilizing effect of constant power load (CPL) is proposed for a DC/DC buck-boost converter. The load profile has been considered to be predominantly of CPL type. The negative incremental resistance of the CPL tends to destabilize the feeder system, which may be an input filter or another DC/DC converter. The proposed sliding mode controller aims to ensure system stability under the dominance of CPL. The effectiveness of the controller has been validated through real-time simulation studies and experiments under various operating conditions. The controller has been demonstrated to be robust with respect to variations in supply voltage and load and capable of mitigating instabilities induced by CPL. Furthermore, the controller has been validated using all possible load profiles, which may arise in modern-day DC-distributed power systems.

Measurement-based Estimation of the Composite Load Model Parameters

  • Kim, Byoung-Ho;Kim, Hong-Rae
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 2012
  • Power system loads have a significant impact on a system. Although it is difficult to precisely describe loads in a mathematical model, accurately modeling them is important for a system analysis. The traditional load modeling method is based on the load components of a bus. Recently, the load modeling method based on measurements from a system has been introduced and developed by researchers. The two major components of a load modeling problem are determining the mathematical model for the target system and estimating the parameters of the determined model. We use the composite load model, which has both static and dynamic load characteristics. The ZIP model and the induction motor model are used for the static and dynamic load models, respectively. In this work, we propose the measurement-based parameter estimation method for the composite load model. The test system and related measurements are obtained using transient security assessment tool(TSAT) simulation program and PSS/E. The parameter estimation is then verified using these measurements. Cases are tested and verified using the sample system and its related measurements.

The Development of High-Current Power Supply System for Electrolytic Copper Foil

  • Luo, An;Ma, Fujun;Xiong, Qiaopo;He, Zhixing
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.399-410
    • /
    • 2015
  • A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.

A Study on Probabilistic Reliability Evaluation Considering Transmission System :TRELSS and TranRel (송전계통을 고려한 확률론적 신뢰도 평가에 관한 연구 : TRELSS and TranRel)

  • 최재석;강성록;트란트롱틴;전동훈;문승필;추진부
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.43-55
    • /
    • 2004
  • This paper presents a study on evaluating the reliability indices considering a transmission system. Because successful operation of electric power under the deregulated electricity market depends on transmission system reliability management, quantity evaluation of transmission system reliability is very important. This paper introduces features and operation modes of the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 6.0, a commercial program made in EPRI, and TranRel-I V3.2, a educational program made in GSNU(GyeongSang National University) for assessing reliability indices of composite power system. The packages access not only bulk but also bus indices for reliability evaluation of composite powers system. The practicality, effectiveness and future works of this methodology are illustrated by demonstrations of two case studies of modified IEEE 25 buses reliability test system using TRELSS and TranRel-I and a brief case study for the KEPCO size system using TranRel-II made in GSNU.

A Study on Prediction of Young's Modulus of Composite with Aspect Ratio Distribution of Short Fiber (장단비 분포를 갖는 단섬유 복합재의 영계수 예측에 대한 연구)

  • Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.99-104
    • /
    • 2006
  • Young's modulus of composite has been predicted by Eshelby's equivalent inclusion method modified with Mori-Tanaka's mean field theory, where short fibers of aspect ratio distribution are assumed to be aligned. Young's modulus of the composite is predicted with the smallest class interval for simulating the actual distribution of fiber aspect ratio, which is compared with that computed using different class intervals. Young's modulus of the composite predicted with mean aspect ratio or the largest class interval is overestimated by the maximum 10%. As the class interval of short fibers for predicting Young's modulus decreases, the predicted results show good agreements with those obtained using the actual distribution of fiber aspect ratio. It can be finally concluded from the study that if and only if the class interval of short fiber normalized by the maximum aspect ratio is smaller than 0.1, the predicted results are consistent with those obtained using the actual distribution of aspect ratio.

  • PDF

A Study on Performance Evaluation of On-board Electric Device of TTX(Tilting Train Express) (틸팅열차(TTX)의 정장품 성능평가 연구)

  • Han, Seong-Ho;Lee, Su-Gil;Seo, Sung-Il
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.239-242
    • /
    • 2005
  • This paper introduced an approach of improvement of performance of Electric device for EMU type Train like as TTX. The electric equipments are characterized by insulation, Noise, cooling system etc. and Their weight arc decided by these factors. There are two kinds of power source in EMU train. First, DC voltage source, 1500 volt, 750 volt is used for subway system. Second, AC power source 25000 volt is applied to high speed train and existing main lines. Composite material has the protection of inrush current and high frequency noise. We can use this material to minimize weight of train. Additionally we can get energy saving when operator service TTX.

  • PDF

The Study for Allowable Capacity of New Distributed Generation for Composite Distribution System Interconnected Distributed Generation (분산전원이 연계된 복합배전개통에 신규분산전원연계시 신규분산전원 도입량에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Choi, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.277-279
    • /
    • 2002
  • Recently, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern for DG(distributed generation) is growing. Present, allowable interconnection capacity of DG for composite distributed generation is studied. In this paper, it is studied that the new interconnection capacity of DG for composite distribution system interconnected DG. We study new allowable interconnection capacity by power factor and placement. We study SERV(sending end reference voltage) variation and allowable interconnection capacity interconnected new DG.

  • PDF

Analyzing Materials Property using Optical Sensing Technique of Stabilizer Link for Automobile Parts (수송기계용 Stabilizer Link의 광센서를 이용한 부품성능평가)

  • Nam, K.W.;Woo, Y.M.;Oh, J.H.;Moon, C.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.47-53
    • /
    • 2010
  • A stabilizer link connects the stabilizer bar to the lower arm of the suspension. When a vehicle is turning, lateral forces from the tire are transmitted through the stabilizer link into the stabilizer bar. The stabilizer bar will twist, thus adding rigidity to the vehicle body. In this study, the stabilizer link body was manufactured by using composite material with POM-GF25%. Therefore, the strength evaluation of stability link body with composite material carried out from tensile, wear and fatigue test. The tensile strength between the stability link body with composite material and the rod with knurling was the largest of four types of rod. In Analyzing materials property using optical sensing technique of stabilizer link for automobile parts, its has been identified the safety.

Design Development Test for Composite Wind Turbine Blade (풍력발전기용 복합재 윈드터빈 블레이드의 설계 개발 시험)

  • Lee Chung-Hun;Jung Sung-Hoon;Park Ji-Sang;Kim Tae-Wook
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.22-25
    • /
    • 2004
  • This paper describes method and procedure for DDT (Design Development Test) of composite wind turbine blade composites. The test type of DDT is bending test, such as cantilever beam, based on the rated wind speed of wind power generation system. DDT was carried out in order to compare with the result of FEM analysis, characterize structural stability, verify manufacturing process and review test method of full scale blade.

  • PDF

Probabilistic Reliability Evaluation of KEPCO System using TRELSS - V (TRELSS를 이용한 우리나라의 확률론적 신뢰도 평가에 관한 연구 - V)

  • Jeon D.;Kim T.;Cha S.;Choo J.;Tran T.;Lee S.;Choi J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.11-14
    • /
    • 2004
  • In recent, the importance and necessity of some studies on reliability evaluation of grid comes from the recent black-out accidents occurred in the world. The quantity evaluation of transmission system reliability is very important under competitive electricity environment. The reason is that the successful operation of electric power under the deregulated electricity market depends on transmission system reliability management. This paper introduces features and operation modes of the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 6.2, a program made in EPRI, for assessing reliability indices of composite power system. The package accesses not only bulk but also buses indices for reliability evaluation of composite powers system. The characteristics of the TRELSS program are illustrated by the case studies using the KEPCO system