• Title/Summary/Keyword: Compliance Curve

Search Result 79, Processing Time 0.026 seconds

Non-linear Resistive Switching Characteristic of ZnSe Selector Based HfO2 ReRAM Device for Eliminating Sneak Current

  • Kim, Jong-Gi;Kim, Yeong-Jae;Mok, In-Su;Lee, Gyu-Min;Son, Hyeon-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.357-358
    • /
    • 2013
  • The non-linear characteristics of ON states are important for the application to the high density cross-point memory industry because the sneak current in neighbor cells occurred during reading, erasing, and writing process. Kw of above 20 in ON states, which is the writing current @ Vwrite/the current @ 1/2Vwrite, was required in cross-point ReRAM memory industry. The high current density non-linear IV curve of ZnSe selector was shown and the ALD HfO2 switching device has the linear properties of ON states and the compliance current of 100 uA. To evaluate the performance of the selection device, we connected itto HfO2 switching device in series. The bottom electrode of the selection device was connected to the top electrode of the RRAM. All of the bias was applied with respect to the top electrode of the selection device, whereas the bottom electrode of the RRAM was grounded. In the cross-point application, 1/2Vwrite and -1/2Vwrite were applied to the word-line and bit-line, respectively, which were connected to the selected cell, and a zero bias was applied to the unselected word-lines and bit-lines. The current @ 1/2Vwrite of the unselected cells was blocked by the selection device, thus eliminating the sneak path and obtaining a writing voltage margin. Using this method, the writing voltage margin was analyzed on the basis of the memory size.

  • PDF

Development of an Strategic Model for the Selection of a National IT R&D Strategic Project (국가 IT R&D 전략과제 선정 모형개발)

  • Ryu, Dong-Hyun;Park, Jeong-Yong;Lee, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.501-509
    • /
    • 2011
  • In this paper, we offer a new strategic Portfolio Model for national IT R&D project selection in Korea. A risk and return (R-R) Portfolio Model was developed using an objectively quantified index on the two axes of risk and return, in order to select a strategic project and allocate resources in compliance with a national IT R&D strategy. We strategize using the R-R Portfolio Model to solve the non-strategy and subjectivity problems of the existing national R&D project selection Model. We also use the quantified evaluation index of the IT technology road map (TRM) and the technology level Survey (TLS) for the subjectivity of project selection, and try to discover the weights using the analytic hierarchy process (AHP). In addition, we intend to maximize the chance for a successful national IT R&D project, by selecting a strategic Portfolio project and balancing the allocation of resources effectively and objectively.

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

Leak Before Break Evaluation of Surge Line by Considering CPE under Beyond Design Basis Earthquake (설계초과지진시 CPE를 고려한 밀림관 파단전누설 평가)

  • Seung Hyun Kim;Youn Jung Kim;Han-geol Lee;Sun Yeh Kang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2022
  • Nuclear Power Plants (NPP) should be designed to have sufficient safety margins and to ensure seismic safety against earthquake that may occur during the plant life time. After the 9.12 Gyeongju earthquake accident, the structural integrity of nuclear power plants due to the beyond design basis earthquake is one of key safety issues. Accordingly, it is necessary to conduct structural integrity evaluations for domestic NPPs under beyond design basis earthquake. In this study, the Level 3 LBB (Leak Before Break) evaluation was performed by considering the beyond design basis earthquake for the surge line of a OPR1000 plant of which design basis earthquake was set to be 0.2g. The beyond design basis earthquake corresponding to peak ground acceleration 0.4g at the maximum stress point of the surge line was considered. It was confirmed that the moment behaviors of the hot leg and pressurized surge nozzle were lower than the maximum allowable loading in moment-rotation curve. It was also confirmed that the LBB margin could be secured by comparing the LBB margin through the Level 2 method. It was judged that the margin was secured by reducing the load generated through the compliance of the pipe.

Evaluation of Fracture Toughness Characteristics of Pultruded CFRP Spar-Cap Materials with Non-woven Glass Fabric for Wind Blade (유리섬유 부직포가 삽입된 풍력 블레이드 인발 성형 스파캡 소재의 파괴인성 특성 평가)

  • Young Cheol Kim;Geunsu Joo;Jisang Park;Woo-Kyoung Lee;Min-Gyu Kang;Ji Hoon Kim
    • Journal of Wind Energy
    • /
    • v.14 no.3
    • /
    • pp.83-90
    • /
    • 2023
  • The purpose of this study is to evaluate the inter-laminar fracture toughness characteristics of CFRP pultrusion spar cap materials reinforced with non-woven glass fabric. Test specimens were fabricated by the infusion technique. A non-woven glass fabric and artificial defects were embedded on the middle surface between two pultruded CFRP panels. Double cantilever beam (DCB) and End Notched Flexure (ENF) tests were performed according to ASTM standards. Fracture toughness and crack propagation characteristics were evaluated with load-displacement curves and delamination resistance curves (R-Curve). The fracture toughness results were calculated by compliance calibration (CC) method. The initiation and propagation values of Mode-I critical strain energy release rate value GIc were 1.357 kJ/m2 and 1.397 kJ/m2, respectively, and Mode-II critical strain energy release rate values GIIc were 4.053 kJ/m2 for non-precracked test and 4.547 kJ/m2 for precracked test. It was found that the fracture toughness properties of the CFRP pultrusion spar-cap are influenced by the interface between the layers of CFRP and glass fiber non-woven.

Determination of Pantothenic acid in Fortified Foods by HPLC (시판 영양강화식품중 판토텐산의 분석)

  • 최윤주;장재희;박혜경;박건상;구용의;황인경;김대병
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.381-385
    • /
    • 2004
  • This study was conducted to develop an HPLC method for determining pantothenic acid in fortified foods which has typically been determined by microbiological assay (MBA) according to AOAC and Korean Food Code approved methods. Pantothenic acid was determined by reversed-phase ion-pair HPLC using UV absorption (200 nm) after extraction with 20 mM potassium phosphate solution by sonication. The recovery of spiked samples and detection limit (LOD) by HPLC were 83.5∼109.6% and 0.5 ppm (mg/kg), respectively. The LOD of the microbiological assay (MBA) was much lower than that of HPLC. The concentrations of pantothenic acid analyzed in all tested samples (n=13) confirmed compliance with declared label claims. The range of recovery ratio by the HPLC method when compared to the microbiological assay was 91.9∼117.6%. There was not significant difference (p<0.01) between the HPLC and MBA methods and the equation of the regression curve was y=1.1428x-0.2269 (r=0.9842). This proposed HPLC method for determining pantothenic acid appears to be suitable for determining pantothenic acid concentrations above 0.25 mg/100 g in fortified foods.

Simultaneous determination for fungicide prochloraz and its metabolites in animal commodities with GC-ECD after hydrolysis (가수분해 후 GC-ECD를 이용한 축산물 중 살균제 Prochloraz 및 그의 대사물의 동시분석)

  • Park, Ji-Su;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.63 no.2
    • /
    • pp.153-159
    • /
    • 2020
  • The analytical method was established for simultaneous determination of fungicide prochloraz and its metabolites in several animal commodities using gas chromatography (GC) coupled with electron capture detector (ECD). Samples including beef meat, pork meat, chicken meat, milk, and egg were hydrolyzed with pyridine hydrochloride which converts prochloraz and its metabolites to 2,4,6-trichlorophenol (2,4,6-TCP) because residue definition for prochloraz was 'sum of prochloraz and its metabolites containing the 2,4,6-trichlorophenol moiety, expressed as prochloraz', for compliance with MRLs from animal commodities. Therefore, residual prochloraz was extracted with acetone, decomposed to 2,4,6-TCP, partitioned with dichloromethane, purified with aminopropyl SPE and quantified as 2,4,6-TCP with GC-ECD. The instrumental limit of quantitation and method LOQ (MLOQ) was 0.01 ㎍/mL and 0.02 mg/kg for prochloraz and 0.005 ㎍/mL and 0.01 mg/kg for 2,4,6-TCP, respectively. The linearity of the calibration curve was good with R2 >0.995 in the range of 0.005-0.2 ㎍/mL. Fortification levels of prochloraz were 0.02 mg/kg (MLOQ) and 0.2 mg/kg (10MLOQ) for recovery tests. Overall recoveries of prochloraz were >90% with <10% of coefficient variation (C.V.). This established analytical method was fully validated and could be useful for quantification of prochloraz and its metabolites in animal commodities as official analytical method.

Preparation and Bioequivalence Test of Acetaminophen Liquid Suppository (아세트아미노펜 액상좌제의 제초 및 생물학적 동등성 평가)

  • 김종국;최한곤;이사원;고종호;이미경
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.213-218
    • /
    • 1998
  • A novel in situ-gelling and mucoadhesive acetaminophen liquid suppository was developed to improve the patient compliance of conventional solid suppository. In this study, acetaminophen liquid suppository, Likipe $n_{R}$, [aminophen/Poloxamer 407/Poloxamer 188/so4ium alginate (5/15/19/0.6%)] with relation temperature at 30-36 "C and suitable gel strength and bioadhesive force, dissolution pattern similar to conventional solid type suppository, Suspe $n_{R}$, was developed. Furthermore, the bioequivalence of two acetaminophen products was evaluated in 16 normal male volunteers (age 22-27 yr, body weight 56-72 kg) following sidle rectal administration. Test product was Likipe $n_{R}$ suppository (Dong-Wha Pharm. Corp., Korea)and reference product was Suspe $n_{R}$204-212 suppository (Hanmi Pharm. Corp., Korea). Both products contain 125 mg of acetaminophen. Four Suppositories of the test and the reference product were administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of acetaminophen was accomplished using HPLC. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{-2}$4h/) (30.14$\pm$8.64 vs 27.98$\pm$ 6.53 $\mu$g .h/ml), maximum plasma concentration ( $C_{max}$) (3.29$\pm$0.87 vs 3.60$\pm$0.66 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.91 $\pm$0.55 vs 2.69$\pm$0.60 h). The differences of mean AUCo $_{24h}$, C-a. and T-between the two products (7.18%, 9.58% and 7.53%, respectively) were less than 20%. The power (1-7) and treatment difference ($\Delta$) for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ were more than 0.8 and less than 0.2, respectively at $\alpha$=0.1. The confidence limits for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ (-0.81 ~13.55%, -1.56~ 17.60 and -3.81 ~18.87%, respectively) were less than $\pm$ 20% at $\alpha$=0.1. These results suggest that the bioavailability of Likipe $n_{R}$ suppository is not significantly different from that of Suspe $n_{R}$ suppsitory. Therefore, two products are bio-equivalent based on the current results.results.lts.sults.results.lts.

  • PDF

Comparison of Two Methods of Recruiting the Acutely Injured Lung (급성 폐손상에서 폐를 Recruit시키는 방법간의 비교 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Kim, Ho-Choel;Young, Lim-Si;Chung, Man-Pyo;Han, Jeong-Ho;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.500-512
    • /
    • 2000
  • Background : To evaluate the efficacy of two methods of obtaining lung recruitment to reduce ventilator-induced lung injury(VILI). Methods : Fifteen New-Zealand white rabbits were ventilated in the pressure-controlled mode while maintaining constant tidal volume(10 ml/kg) and fixed respiration rate. Lung injury was induced by repeated saline lavage (PaO2<100 mmHg), and the pressure-volume curve was drawn to obtain Pflex. The animals were then randomly assigned to three groups and ventilated for 4 hours. In the control group(n=5), positive end-expiratory pressure(PEEP) less than that of Pflex by 3 mmHg was applied throughout the study. In the recruitment maneuver(RM) group(n=5), RM(CPAP of 22.5 mmHg, for 45 seconds) was performed every 15 minutes in addition to PEEP level less than Pflex by 3 mmHg This phrase is unclear. In the Pflex group, PEEP of Pflex was given without RM. Gas exchange, lung mechanics, and hemodynamics parameters as well as pathology were examined. Results : 1) Both the control and RM groups showed decreasing tendency in PaO2 with time. There was significantly decreased PaO2 at 4 hr compared to Ihr(p<0.05). But in the Pflex group, PaO2 did not decrease with time(p<0.05 vs other groups at 3, 4 hr). PaCO2 did not show significant difference among the three groups. 2) There was no significant difference in static compliance and plateau pressure. Mean blood pressure and heart rate also did not show any significant difference among the three groups. 3) The pathologic exam showed significantly less neutrophil infiltration in the Pflex group than in the control group(p<0.05). There was borderline significant difference in hyaline membrane score among the groups (p= 0.0532). Conclusion : Although recruitment maneuver of the injured lung may be important in decreasing VILI, it alone may not be sufficient to minimize VILI.

  • PDF