• Title/Summary/Keyword: Complete mandibular denture

Search Result 95, Processing Time 0.018 seconds

Comparison of treatments for maxillary full denture and mandibular implant-supported fixed prosthesis in completely edentulous patients: A case report (완전 무치악 환자에서 상악 총의치와 하악 임플란트 지지 고정성 보철 치료를 위한 치료법 비교: 증례 보고)

  • Jin-Won Han;Se-Wook Pyo;Jae-Seung Chang;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.73-81
    • /
    • 2023
  • There are various approaches to treatment for patients with fully edentulous jaw. In maxilla, it is easy to obtain sufficient stability, support, and retention with the traditional full denture method. In mandible, however, there are difficulties caused by anatomical limitations. In this case, treatment with implants can be considered. If it is difficult to place implants in posterior area, a fixed complete denture can be considered, using 4 - 5 implants anterior to mental foramen. This approach has changed in many ways, such as surgical methods and materials used, over the years. This case report compares two approaches and their changes over time, especially in the cases of mandibular fixed prostheses using implants, paired with maxillary complete denture.

Phonetic improvement by adjusting the shape of the anterior palate of the maxillary complete denture: a case report (상악 총의치 전방 구개 부위 형태 조정을 통한 발음개선 증례)

  • Yoon, Myeong Ah;Lee, HagYoung;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.37-43
    • /
    • 2022
  • Patients tend to return to normal pronunciation patterns after fitting new dentures. However, for some patients, it takes a long time to adapt the new complete denture. In this case, the patient came to the hospital at the address of wanting to remake dentures due to wear and tear. After diagnosis through clinical and radiological examination, the maxillary complete denture and mandibular removable partial denture were remade. The patient complained whistling /s/ sound at the first check-up after placement of the new denture. The anterior palatal area of polished surface of the new maxillary complete denture was concave comparing to old denture, and this was the cause of the whistling /s/ sound. A tissue conditioning material was applied to the maxillary complete denture and patient made /s/ sound. The tissue conditioning material was replaced with self-curing type denture base resin, and the patient was immediately satisfied with clear /s/ sound. As an objective assessment, palatogram and speech analytics software was applied. In this case, a patient who received denture treatment complaining of difficulty in pronunciation underwent immediate denture repair, which resulted in patient satisfaction and improved pronunciation through objective evaluation.

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

Complete denture rehabilitation of fully edentulous patient with severe bone resorption and class II jaw relation using piezography (심한 골 흡수와 2급 악간관계를 보이는 완전 무치악 환자의 Piezography를 이용한 총의치 수복)

  • Kwon, Wooil;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.445-450
    • /
    • 2016
  • Piezography, prosthetic space recorded by pronunciation, can be used as a reference for arrangement of artificial teeth and polishing surface of a denture. In this case, a 67 year old female patient was presented for new dentures. Old dentures had class II relationship and poor retention. For fabrication of stable dentures, using piezography and lingualized occlusion was planned. After taking impressions with conventional method, conventional denture bases with wax rim were fabricated. Then, additional mandibular denture base was fabricated for piezography. With fast setting silicon impression material, piezography was recorded by using six pronunciations, 'si', 'so', 'me', 'te', 'de', and 'mu'. According to the piezographic space, mandibular artificial teeth were arranged and modified for lingualized occlusion. As a result, the patient was satisfied with new dentures functionally and esthetically.

Comparative analysis of case series for the prosthetic rehabilitation of edentulous patients using suction denture (완전 무치악 환자들을 위한 보철 수복 시 흡착 의치를 이용한 비교 분석 증례)

  • Kim, Ye-Ji;Song, Young-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.389-396
    • /
    • 2019
  • In patients with severely resorbed alveolar bone, it is difficult to gain retention in denture. Lack of retention makes denture unstable and lead to trouble in using denture. Suction denture seals the entire denture border with movable mucosa and this sealing mechanism forms negative pressure beneath the denture and produce higher retention and stability to denture. In this case, 4 edentulous patients visited for lack of retention with dentures. Considering their high expectation with retention, suction denture concept was used to fabricate retentive and stable denture. The purpose of this case report is to compare and analyze the considerations of suction denture restorations in edentulous patients.

Fabrication of CAD-CAM complete denture using existing provisional denture and digital facebow transfer (기존 임시의치와 디지털 안궁이전을 이용하여 상하악 CAD-CAM 총의치 수복 증례)

  • Jaehyeok Ro;Haemin Bang;Sangwon Park;Hyun-Pil Lim;Kwi-Dug Yun;Chan Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.268-274
    • /
    • 2023
  • In this case, a CAD-CAM complete denture that can be easily remanufactured and reduced the number of visits was decided in consideration of the fact that it was difficult to visit the dental hospital and many existing dentures were lost because the patient was inpatient in a nursing hospital. In order to reflect the shape, vertical dimension, and maxillomandibular relationship of the existing provisional dentures adapted by the patient to the fabrication of the final denture, the existing provisional dentures were scanned and closed mouth impression was taken with the printed individual tray. After digital facebow transfer using UTS CAD and arranging artificial teeth in CAD software, the maxillary and mandibular complete dentures were fabricated by milling the denture base and artificial teeth at once with the monolithic disc.

Management of flabby ridges using liquid supported denture: a case report

  • Keni, Nandita Nitin;Aras, Meena Ajay;Chitre, Vidya
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.43-46
    • /
    • 2011
  • Flabby ridges commonly occur in edentulous patients. Inadequate retention and stability of a complete denture are the often encountered problems in these patients. A liquid supported denture due to its flexible tissue surface allows better distribution of stress and hence provides an alternate treatment modality in such cases. This case report presents the use of a liquid supported denture in a patient with completely edentulous maxillary arch with flabby tissue in anterior region opposing a partially edentulous mandibular arch.

Comparison between denture wearer's evaluation and clinician's rating for complete denture (총의치 사용에 대한 환자와 술자간 평가 비교)

  • Byun, Jin-Soo;Huh, Yoon-Hyuk;Cho, Lee-La;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.364-369
    • /
    • 2016
  • Purpose: The aim of this study was to compare denture wearer's evaluation and clinician's technical rating for complete denture used on edentulous patients. Materials and methods: Total 43 edentulous patients who had complete denture fabricated more than one year ago were recalled. The questionnaire based on the various literatures was modified and applied to patients for subjective assessments. Functional aspects related to retention, stability, occlusion and denture condition were included in operator's evaluation. In addition, correlations were evaluated between patient's subjective and operator's objective assessments. Friedman test and Cohen's Kappa value were used for statistical analysis. Results: It was found that denture wearers' evaluations were slightly or fairly agree to clinician's rating for complete denture. More differences were found in maxillary denture than mandibular denture and moderate difference was found in esthetic, occlusion aspects. Conclusion: There were slightly or fairly agreement between subjective and objective evaluations.

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

  • Guo, Ying;Kono, Kentaro;Suzuki, Yasunori;Ohkubo, Chikahiro;Zeng, Jian-Yu;Zhang, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P<.05), while there was no statistical difference between the normal and resorption group (P>.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P<.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.