• Title/Summary/Keyword: Complete edentulous

Search Result 161, Processing Time 0.018 seconds

PHOTOELASTIC ANALYSIS OF MANDIBULAR STRESSES INDUCED BY LINGUALIZED OCCLUSION (Lingualized Occlusion에 의한 하악응력의 광탄성학적 분석)

  • Kim, Sang-Soo;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.153-169
    • /
    • 1988
  • There is a little scientific documentation reporting the stress, distribution to the edentulous mandible by different concepts of occlusal scheme. So, this study was to investigate the hypothesis that the magnitude and distribution of the occlusal stresses, transmitted through a mandibular complete denture base to the edentulous mandible, would be influenced by the lingualized occlusion. This investigation was performed to analyze the stresses induced in a three-dimensional photoelastic edentulous mandible, when a load is applied to the denture arranged into lingualized occlusion in centric relation, lateral and protrusive functional position. The mounted denture on a Dentatus Type ARO articulator was loaded in a pure vertical direction with 15kgs on the center of articulator in each case and the stresses were frozen into epoxy edentulous model at $127^{\circ}C$ in the stress freezing furnace. The stress-frozen epoxy models were sliced with diamond disc saw into 4mm thick. The slices were examined with a circular polariscope. The results were as follows: 1. In centric relation, the stresses were low at anteriors, and gradually increase to the premolar, molar area and highest at the first molar and gradually decrease from the second molar and lowest at the retromolar pad region. The lingual side showed higher stresses than labiobuccal side. 2. In lateral functional position, the working side showed higher stresses than the balancing side. In working side, the lingual side showed higher stresses than the buccal side and in balancing side, the buccal side showed higher stresses than the lingual side. 3. In protrusive position, stress distribution was symmetrical on the posteriors and the stresses were concentrated at the labial side of the anteriors.

  • PDF

Implant overdenture treatment using several solitary attachment systems on mandibular edentulous patients (하악 무치악 환자에서 수종의 어태치먼트를 이용한 임플란트 피개의치 수복 증례)

  • Park, Mid-Eum;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.242-252
    • /
    • 2015
  • Implant overdenture treatment using several solitary attachment systems on mandibular edentulous patients. Most patients with severe residual ridge resorption report significantly more problems adapting to their mandibular denture due to a lack of comfort, retention, stability and to the inability to chew and eat. Recent scientific studies carried out over the past decade have determined that the benefits of a mandibular implant overdenture are sufficient to get retention and stability. Therefore, overdenture with implants on the mandible and attachments are considered as a treatment of choice as a favorable treatment. In this cases, with consideration for jaw relation, level of bone loss, facial support and economic factor, edentulous patients with severe residual ridge resorption are rehabilitated by complete denture on maxilla and two-implants overdenture using several solitary attachment systems on mandible.

A study on the determining of vertical dimension of occlusion of edentulous patients using korean phonetic patterns (한국어 음성모형을 이용한 총의치 환자의 교합고경 결정에 관한 연구)

  • Song, Kwang-Seob;Song, Kwang-Yeob;Cho, Kook-Hyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.187-196
    • /
    • 2000
  • This study was performed to offer convenience to determine the vertical dimension of occlusion of edentulous patients by investigating the interocclusal distances at physiologic rest position, at speaking of /m/ sound, and some korean short sounds, that is, /mem/ and /beb/ sounds, which were found in our previous study with dentulous subjects. Ten edentulous subjects - 6 men and 4 women - were selected for this study. The frequencies at speaking of /m/, /mem/, and /beb/ sounds were analyzed with Computerized speech lab($CSL^{TM}$, Model 4300B, Software version 5.X, Kay Elemetrics Co. U.S.A.). And the interocclusal distances at physiologic rest position and at speaking of /m/, /mem/, and /beb/ sounds were measured with K6 diagnostic system(Myo-tronics, Inc. U.S.A.). The results of this study were as follows ; 1. In the acoustic analysis by Computerized speech lab, frequencies of sounds of edentulous subjects with complete denture at speaking of /m/, /mem/, and /beb/ were similar to those of dentulous subjects. 2. In the linear correlation by Pearson's correlation coefficient, the interocclusal distance at physiologic rest position was most similar to those of speaking /mem/ sound, secondly /m/ sound, and thirdly /beb/ sound(p<0.05). In reliability by Cronbach's alpha, the results were reliable with alpha value 0.97. 3. It was found by Levene's test for equality of variance that the difference between men and women in the interocclusal distances at physiologic rest position and at speaking of /m/, /mem/, and /beb/ sounds was not statistically significant(p>0.05).

  • PDF

The artificial teeth arrangement and occlusion for Complete denture (총의치를 위한 인공치배열과 교합)

  • Song, Young-Gyun
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.411-417
    • /
    • 2015
  • In an edentulous situation, the oral rehabilitation with complete denture is substantially different from treatment of natural teeth. The artificial teeth arrangement and occlusion are important factor for the stability of the denture. Bilateral balanced occlusion is that stability of the denture is attained when bilateral contacts exist throughout all excursion and static states of the denture during function and, artificial teeth are arrangement in neutral zone where the forces between the tongue and cheeks or lips are equal. This is how dentist make a favorable prognosis. Therefore, dentists are have to be a little more involved in the selection and arrangement of artificial teeth.

Esthetically improved complete denture by gingival shade alteration: a case report (무치악 환자에서 치은의 색조 개선을 통해 심미성을 향상 시킨 총의치 수복 증례)

  • Yim, Soo-Hyun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.239-245
    • /
    • 2014
  • Complete denture prosthodontics includes replacement of natural teeth and associated maxillary and mandibular structures for full edentulous patients. The final objectives of prosthodontic treatment include esthetic and functional rehabilitation. Because the esthetic demand of senior patients has increased esthetic requirement should not be overlooked in denture treatment. In complete denture treatment, attempts have been made to reproduce tooth wear, arrangement, recession of cervical gingiva, staining, improved gingival shade and so on. This 61 year old female patient came to the Department of Prosthodontics with the chief complaint that dentures made 5 years ago in a local clinic were broken and did not fit well. The patient put more emphasis on fabrication of natural and esthetic dentures than recovery of masticatory function. Remake of maxillary complete denture and mandibular implant retained overdenture was planned. In order to create esthetic and natural contour, Aesthetic Color Set Easy system$^{(R)}$ (Candulor dental GmbH, Wangen, Germany) was used to make complete dentures reproducing various gingival shades. Patient's esthetic satisfaction was high. When complete denture prosthodontics treatment involves appropriate expression of individual characteristics in addition to proper selection of esthetic materials, treatment will give satisfaction to both dentist and patient.

Complete denture made with closed-mouth impression technique on severely atrophied edentulous jaw (하악 치조골이 심하게 위축된 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Lee, Suk-Hwan;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.195-202
    • /
    • 2019
  • At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

Metal base of complete denture in edentulous patient (무치악 환자에서 총의치 금속상에 대한 고찰)

  • Koo, Cheol-Ihn;Lee, Heung-Tae;Park, Chan-Ik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.197-204
    • /
    • 2002
  • Polymers are the dominant material for fabrication of denture bases. However, resin base can't fufill the patients' satisfactions completely and solve the pronunciation problem and prevent the denture fracture. In spite of many advantages, metal denture bases do not widespread in clinical practice. The main reasons are the difficulties in fabrication and additional time and cost, inability to rebase such prostheses. The use of the metal base can be one of options in complete denture treatments. This study helps, through reveiwing previous reports and literature about the metal base, metal base to be useful in the clinical application by recommend the materials, indications and advantage/disadvantage of the metal base and introduce variable designs. The clinical application of the metal base have many advantages, but the dentists have to select cases carefully and apply designs according to patient's various conditions. In conclusion, the use of the metal base can't alternate treatment of inadequate conventional complete denture. Adequate complete denture is very important for the treatment of the metal base complete denture.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

A CLINICAL STUDY ON THE SATISFACTION OF COMPLETE DENTURE PATIENTS (총의치 환자의 만족도에 대한 연구)

  • Kim, Hyung-Woo;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.440-452
    • /
    • 1995
  • A success of complete denture prosthesis can be determined by the satisfaction degree of the dentist and the patient. There are many factors influencing on the satisfaction of the complete denture patients. The purpose of this study is to analyze the correlation between the masticatory satisfaction and clinical evaluation, and the speech satisfaction and clinical evaluation in complete denture patients. 79 patients(total 119 complete dentures) were examined in this study who were treated in Seoul National University Dental Hospital. Through clinical evaluation, 2 examiners evaluated sex, age, edentulous period, the years of having used present complete denture, the number of the previous dentures, the state of the opposite arch, retention, stability, support, occlusion, vertical dimension of the complete denture and the condition of the residual alveolar ridge. Through questionnaires concerned with mastication and speech, examiners evaluate the satisfaction degree of the patients. This study led to the conclusion that : 1. The satisfaction degree of the mastication was lower in older patients(p<0.001) and in patients whose present complete denture period was shorter(p<0.05). The satisfaction degree of the mastication in male was higher than in female patients(p<0.01). 2. The satisfaction degree of the mastication was high when the retention of the complete denture was good(p<0.05), and when the condition of the residual alveolar ridge was good(p<0.05). 3. The satisfacion degree of the speech was high when the retention of the complete denture was good(p<0.01). 4. The satisfaction degree of the mastication was higher in patients with upper and lower complete denture than in patients with single complete denture whose oppsite arch was unilateral partial denture(p<0.05).

  • PDF