• 제목/요약/키워드: Compensation current

검색결과 1,239건 처리시간 0.035초

역률개선 및 고조파 보상을 위한 능동전력필터에 관한 연구 (A Study on Active Power Filter for Compensation of Power Factor and Harmonic Currents)

  • 김용호;김진수;권기현;정용호;최경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1074-1076
    • /
    • 1992
  • By using nonlinear loads in power line, reactive power and harmonics are occured. In this thesis, on the basis of the instantaneous reactive power theory, the calculation method of compensation current commands and the current control characteristics of active power filter using voltage source PWM converter are presented. The calculation of compensation current is performed by DSP within 50 usec. And the Pl control of current is performed by analog devices. The compensations of harmonic current in rectifier loads and unbalance currents are proved by experiments.

  • PDF

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

개선된 변류기 2차 전류 보상알고리즘을 적용한 모선보호용 비율전류차동 계전방식 (A Percentage Currant Differential Relaying Algorithm for Bus Protection Using an Advanced Compensation Algorithm of the Secondary Current of CTs)

  • 강용철;윤재성;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.9-11
    • /
    • 2002
  • This paper proposes a percentage current differential relaying algorithm for bus protection using an advanced compensation algorithm of the secondary current of CTs. A percentage current differential relaying algorithm may maloperate in case of external faults with CT saturation. Thus, it needs an additional method to cope with CT saturation. The advanced compensation algorithm is unaffected by a remanent flux. The proposed relaying algorithm does not need any additional methods for CT saturation and is unaffected by the remanent flux and has the wide operating zone of current differential relays.

  • PDF

유연송전시스템에서의 역률 보상을 위한 배전용 정지형 동기조상기의 전류제어 (Predictive Current Control of Distribution Static Condenser (D-STATCON) for Reactive Power Compensation in Flexible AC Transmission System(FACTS))

  • 오관일;문건우;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.447-454
    • /
    • 1998
  • This paper describes a modeling and current control techniques of Distribution static condenser (D-STATCON) for power factor compensation. The current control is based on the predictive and the space vector PWM scheme. The predictive current controlled PWM D-STATCON can maintain its performance with power factor compensation and fixed switching frequency. By using the space vector control low ripple and offset in the current and the voltage as well as fast dynamic responses are achieved with a small DC link capacitance employed.

  • PDF

A Novel Compensator for Eliminating DC Magnetizing Current Bias in Hybrid Modulated Dual Active Bridge Converters

  • Yao, Yunpeng;Xu, Shen;Sun, Weifeng;Lu, Shengli
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1650-1660
    • /
    • 2016
  • This paper proposes a compensator to eliminate the DC bias of inductor current. This method utilizes an average-current sensing technique to detect the DC bias of inductor current. A small signal model of the DC bias compensation loop is derived. It is shown that the DC bias has a one-pole relationship with the duty cycle of the left side leading lag. By considering the pole produced by the dual active bridge (DAB) converter and the pole produced by the average-current sensing module, a one-pole-one-zero digital compensation method is given. By using this method, the DC bias is eliminated, and the stability of the compensation loop is ensured. The performance of the proposed compensator is verified with a 1.2-kW DAB converter prototype.

A Dead Time Compensation Algorithm of Independent Multi-Phase PMSM with Three-Dimensional Space Vector Control

  • Park, Ouk-Sang;Park, Je-Wook;Bae, Chae-Bong;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.77-85
    • /
    • 2013
  • This paper proposes a new dead time compensation method of independent six-phase permanent magnet synchronous motors (IS-PMSM). The current of the independent phase machines contains odd-numbered harmonics because of the dead time and the nonlinear characteristics of the switching devices. By using the d-q-n three-dimensional vector analysis, these harmonics can be extracted at the n-axis current. Thus, the current distortion can be compensated by controlling the n-axis current of the IS-PMSM to zero. The proposed method is simple and can be easily implemented without additional hardware setup. The validity of the proposed compensation method is verified with simulations and several experiments.

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

의료사고피해 구제제도의 제 모형 (Models of Social Relief Schemes for Medical Malpractice)

  • 문옥륜;이기효
    • 보건행정학회지
    • /
    • 제2권1호
    • /
    • pp.80-114
    • /
    • 1992
  • Current compensation schemes for medical malpractice based on negligence is absolutely malfunctioning in Korea. Focussing on the reform of present tort systems for resolving medical malpractice disputes, this paper discusses the alternative models of the Social Relief Schemes for Medical Malpractice (SRSMM). Alternative models of SRSMM should fundamentally be based on either negligence or nofalult compensation principle. On the foundation of the previous relief principle, the SRSMM should be equupped with three major components-the preventio/reduction of the sharp increasing medical malpractice, the effective and efficient resolving process for malpractice disputes and the proper social financing scheme for compensation. The paper deals with pros and cons of the possible alternative models for reform centering on the three major components of the scheme. As conclusions, administrative arbitration machinaries and a compulsory fund for compensating the injured under the negligence principle are proposed to resolve the current problems Korea has faced.

  • PDF