• Title/Summary/Keyword: Compartment Model

Search Result 313, Processing Time 0.034 seconds

Health Risk Assessment due to 137Cs Released into Ocean from the Severe Accident of the Fukushima Dai-ichi Nuclear Power Plants (후쿠시마 사고로 해양으로 누출된 137Cs에 의한 인체 위해도 평가)

  • Min, Byung Il;Lee, Baek Gun;Suh, Kyung Suk;Park, Kihyun
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.123-132
    • /
    • 2014
  • After the nuclear accident of the Fukushima Dai-ichi Nuclear Power Plants (FDNPPs) on 11 March 2011, a large amount of radioactive materials has been released into the atmosphere and the ocean. A compartment model is used to evaluate the circulation characteristics and the spatiotemporal concentration distributions of radionuclides in the ocean. In the comparison with observed concentrations of $^{137}Cs$ in seawater, calculated concentrations by the compartment model were well agreed with them. On the basis of these results, we performed evaluation of the effective dose and the cancer risk. In the early stage of the accident, the effective doses from ingestion of the seafood near the Fukushima region were much higher than 1 mSv which is the value of the annual effective dose limit to individual recommended by the International Commission on Radiological Protection (ICRP). However, the effective doses by ingestion of the seafood decreased below 1 mSv as distance from the FDNPPs increased and time passed. In addition, it was estimated that the cancer risks by intake of the contaminated marine products were less than natural occurrence probability of cancer. Consequently, it was inferred that the health risk due to the $^{137}Cs$ was low after since mid-term period of the accident.

Influence of Major Urban Construction on Atmospheric Particulates and Emission Reduction Measures

  • Wang, Shunyi;Zhou, Ping;Lin, Limin;Liu, Chuankun;Huang, Tao
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.215-231
    • /
    • 2018
  • In order to understand the variation of air quality and the concentration of atmospheric particulates in Chengdu Second Ring Road renovation project, this paper starts to investigate the surrounding residents' opinions on the influenced environment and their daily lives via questionnaires. Then the study numerically simulates the change rule of atmospheric particulates in terms of time and space by using the Gaussian dispersion-deposition model and the compartment model. The optimized scientific scheme is selected by the improved fuzzy analytical hierarchy process(FAHP) to help decision making for the future urban reconstructions. Finally, the reduced emissions of atmospheric particulates are measured when the improvement scheme is provided. According to the study, it can be concluded that the concentration of atmospheric particulates increases rapidly in central Chengdu city during the renovation project, which results in worsening air quality in Chengdu during March 2012 to March 2013. Taking related measures on energy saving and emission reduction can effectively reduce the concentration of atmospheric particulates and promote economic, environmental and social coordination.

Numerical Study of Effect of counter-pulsation on Hemodynamic Response in the ECLS (체외생명구조장치에서 역박동 방법이 혈류역학 응답에 미치는 영향에 대한 수치적 연구)

  • Kim, In-Su;Lim, Ki-Moo;Choi, Seoung-Wook;Jun, Hyung-Min;Shim, Eun-Bo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1660-1664
    • /
    • 2008
  • Extra-corporeal Life Support System (ECLS) is the device used in emergency cases to substitute a extracorporeal circulation in open heart surgery, cardiac arrest or in acute cardiopulmonary failure. To obtain the effect of counter-pulsation on hemodynamic response in the ECLS quantitatively, we developed cardiovascular model which consists of 12 compartment model of heldt et al. and 3 compartment model of Schreiner et al. based on windkessel approximation. We compared coronary perfusion, arterial pulse pressure, cardiac output, and left ventricular pressure-volume diagram according to flow configuration such as counter-pulsation, copulsation, and continous flow. When counter-pulsation was applied, 5% higher coronary perfusion, 26% lower pulse pressure, and 2% higher cardiac output than copulsation condition were calculated. We conclude that counter-pulsation configuration in the ECLS is hemodynamically more stable than copulsation and influences the positive effect to recover ventricles.

  • PDF

Estimation of Straight Line Stability of a Damaged Surface Combatant through Spiral Maneuver Test Model Considering Asymmetry (비대칭성이 고려된 나선형 시험 모델을 통한 손상 수상함의 직진 안정성 추정)

  • Ha, Jeong Soo;Jeong, Yeon Hwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.110-117
    • /
    • 2020
  • In this paper, we estimated the straight line stability by performing a 3 degree of freedom spiral test simulation of a intact/damaged surface combatant using the hydrodynamic coefficient obtained through the PMM(Planar motion mechanism) test based on system engineering process. A model ship was ONR Tumblehome and damaged compartment was set on the starboard bow. As a result of conducting a spiral test simulation based on the experimental results of J.Ha (2018), the asymmetric straight line stability due to the damaged compartment was confirmed. In the case of a ship in which the starboard bow was damaged, it was confirmed that it had the characteristic to deflect to the left when going straight. Also, when estimating the straight line stability of a both port and starboard asymmetric surface combatant, a separated equation of motion model that sees the port and starboard as different ships seems suitable.

Comparative Study on the Committed Dose Equivalent for Adults and Infants (예탁선양치(預託線量値)에서 본 성인(成人)과 유아(幼兒)와의 비교연구(比較硏究))

  • Sung, Kye-Yong;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.76-89
    • /
    • 1984
  • Weighted committed dose equivalents($W_T\;H_{50}$) per intake of unit activity of four nuclides-I-131, I-133, Cs-134 and Cs-137-, which was based on the concepts of ICRP Pub. 30, are calculated for adult who is 70 kg and 25 years old and, for infant who is 10 kg and 1 year old. Metabolism of iodine taken through oral or inhalation pathway is described by using the three-compartment model which consists of inorganic, thyroid and organic compartment. After intake, the amount of iodine in every compartment is calculated by solving the transfer equations among the these compartments. As soon as caesium is taken into the body, it is distributed uniformly in the body through the transfer compartment. In this case, the amount of caesium in total body is calculated by using the total body compartment model which is divided into two tissue compartments because of their different biological half-lifes of caesium in body. As a result of calculations, whether oral or inhalation pathway, the values of ($W_T\;H_{50}$) per intake of unit activity of I-131 for infants are about ten times as much as those of adults. On the other hand, for Cs-134 and Cs-137, the values of $W_T\;H_{50}$ per intake of unit activity show that, whether adults of infants, they have almost the same values.

  • PDF

Hydrodynamics and parametric study of an activated sludge process using residence time distribution technique

  • Sarkar, Metali;Sangal, Vikas K.;Bhunia, Haripada
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.400-408
    • /
    • 2020
  • Hydrodynamic study of Activated Sludge Process (ASP) is important to optimize the reactor performance and detect anomalies in the system. Residence time distribution (RTD) study has been performed using LiCl as tracer on a pilot scale aeration tank (AT) and ASP, treating the pulp and paper mill effluent. The hydraulic performance and treatment efficiency of the AT and ASP at different operating parameters like residence time, recycle rate was investigated. Flow anomalies were identified and based on the experimental data empirical models was suggested to interpret the hydrodynamics of the reactors using compartment modelling technique. The analysis of the RTD curves and the compartment models indicated increase in back-mixing ratio as the mean hydraulic retention time (MHRT) of the tank was increased. Bypassing stream was observed at lower MHRT. The fraction of dead zone in the tank increased by approximate 20-25% with increase in recycle rate. The fraction of the stagnant zone was found well below 5% for all performed experiments, which was under experimental error. The substrate removal of 91% for Chemical oxygen demand and 96% for Biochemical oxygen demand were observed for the ASP working at a hydraulic mean residence time 39 h MRT with a 20% recycling of activated sludge.

An Experimental Study on the Flow Characteristics with the Impinging Angles of Defrost Nozzle Jet Inside a Vehicle Passenger Compartment (차실내 Defrost 노즐 분류의 충돌각 변화에 따른 유동특성에 관한 실험적 연구)

  • Kim, Duck-Jin;Kim, Hyun-Joo;Rho, Byung-Joon;Lee, Jee-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.1024-1032
    • /
    • 2007
  • The flow characteristics with the impinging angles of defrost nozzle jet inside a commercial vehicle passenger compartment were investigated experimentally by using the two-dimensional duct-nozzle model. The shape of the nozzle contraction was designed according to the curved line of cubic equation to the vertical plan of the flow direction. The impinging angles, defined as the angle between nozzle axis and a vertical line to the windshield, were varied from the $0^{\circ}\;to\;80^{\circ}$. The mean velocity distributions, the half-widths, and the momentum distributions with the cases of both the free jet and the impinging jet onto the dummy windshield were measured. The impinging jet flows similarly with wall jet from $X/b_o=20$, and the impinging angle has an effect on the half-width of the impinging jet. The momentum distributions onto the windshield increased with the increase of impinging angle, and then their inflection point was observed around the impinging angle of $60^{\circ}$.

Heat Flux Calculation for Thermal Equilibrium of Cofferdam in a LNG Carrier (LNG선 Heating Coil의 설계를 위한 Cofferdam내 열정산)

  • Joo-Ho Heo;Young-Bum Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.1
    • /
    • pp.98-106
    • /
    • 1998
  • This paper shows the temperature distribution of double hull compartment and of cofferdam in a large LNG Carrier. In LNG Carrier, due to the lower cargo temperature($-163^{\circ}C$), structures are forced to lose their strength if additional heat is not supplied. So it is very important to estimate the temperature distribution and the heat flux needed to maintain the structure properly. The temperature of each compartment is obtained using 2-dimensional model analysis and compared with 3-dimensional results. And also this paper gives preliminary estimation of pipe length to supply necessary heat flux in bare pipe and finned pipe.

  • PDF

Pharmacokinetic Modeling and Simulation of the Carrier-Mediated Hepatic Transport of Organic Anions (음이온계 약물의 간수송과정에 있어서 담체매개 수송의 약물동력학적 모델링 및 시뮬레이션)

  • 이준섭;강민희;김묘경;이명구;정석재;심창구;정연복
    • YAKHAK HOEJI
    • /
    • v.47 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • The purpose of the present study was to kinetically investigate the carrier-mediated uptake in the hepatic transport of organic anions, and to simulate the ″in vivo counter-transport″ phenomena, using kinetic model which was developed in this study. The condition that the mobility of carrier-ligand complex is greater than that of free carrier is not essential for the occurrence of ″counter-transport″ phenomenon. To examine the inhibitory effects on the initial uptake of a ligand by the liver, it is necessary to judge whether the true counter-transport mechanism (trans-stimulation) is working or not. The initial plasma disappearance curves of a organic anion were then kinetically analyzed based on a flow model, in which the ligand is eliminated only from the peripheral compartment (liver compartment). Moreover, ″in vive counter-transport″ phenomena were simulated based on the perfusion model which incorporated the carrier-mediated transport and the saturable intracellular binding. The ″in vivo counter-transport″ phenomena in the hepatic transport of a organic anion were well demonstrated by incorporating the carrier-mediated process. However, the ″in vivo counter-transport″ phenomena may be also explained by the enhancement of back diffusion due to the displacement of intracellular binding. In conclusion, one should be more cautious in interpreting data obtained from so-called ″in vivo counter-transport″ experiments.

A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.