Validation of FDS for Predicting the Fire Characteristics in the Multi-Compartments of Nuclear Power Plant (Part I: Over-ventilated Fire Condition) (원자력발전소의 다중 구획에서 화재특성 예측을 위한 FDS 검증 (Part I: 과환기화재 조건))

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Park, Jong Seok;Do, Kyusik
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.31-39
    • /
    • 2013
  • The Fire Dynamics Simulator (FDS) has been applied to simulate a full-scale pool fire in well-confined and mechanically ventilated multi-compartments representative of nuclear power plant. The predictive performance of FDS was evaluated through a comparison of the numerical data with experimental data obtained by the OECD/NEA PRISME project. To identify clearly the FDS results regarding to the user-dependence in the process of FDS implementation except for the intrinsic limitation of FDS such as simple combustion model, only the over-ventilated fire condition was chosen. In particular, the importance of accurate boundary conditions (B.C.) in mechanically ventilated system were discussed in details. It was known from FDS results that the B.C. on inlet and outlet vents did significantly affect the thermal and chemical characteristics inside the compartments. Finally, it was confirmed that the FDS imposed an accurate ventilation B.C. provided qualitatively good agreement with temperatures, heat fluxes and concentrations measured inside the nuclear-type multi-compartments.

The Pharmacokinetics of Erythromycin in Cultured Paralichthys olivaceus after Oral administration (경구투여에 의한 양식산 넙치내 Erythromycin의 약물동태학적 특성 분석)

  • Seo, Jung-Soo;Jeon, Eun-Ji;Jung, Sung-Hee;Park, Myung-Ae;Kim, Na-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.2
    • /
    • pp.316-321
    • /
    • 2014
  • The pharmacokinetics of erythromycin (EM) after oral administration was studied in the cultured olive flounder, Paralichthys olivaceus, using LC/MS/MS. After single- or multiple-dose administration of EM (50, 100, 200 mg/kg body weight and 50 mg/kg for 5 days) by oral route in olive flounder ($350{\pm}40g$, $22{\pm}0.5^{\circ}C$), the concentration in the serum was determined at 1, 3, 6, 9, 24, 72, 120, 168, 264, 360, 504 and 720 h post-dose. The kinetic profile of absorption, distribution and elimination of EM in serum were analyzed fitting to a two-compartment model by WinNonlin program. The area under the concentration-time curve (AUC), maximum concentration ($C_{max}$), time for maximum concentration ($T_{max}$) following oral administration of 50, 100 and 200 mg/kg b.w. and 50 mg for 5 days. EM was $165.3hr^*{\mu}g/m{\ell}$ ($C_{max}$, $34.63{\mu}g/m{\ell}$; $T_{max}$, 1.56 hr), $212.8hr^*{\mu}g/m{\ell}$ ($C_{max}$, $60.38{\mu}g/m{\ell}$; $T_{max}$, 3.99 hr), and $592.37hr^*{\mu}g/m{\ell}$ ($C_{max}$, $63.01{\mu}g/m{\ell}$; $T_{max}$, 4 hr), respectively. The results of this study related to dosage and ${\mu}{\cdot}$withdrawal times could be used for prescription of EM in field for the treatment of bacterial diseases in olive flounder.

Experimental Study on Free Roll Decay Motions of a Damaged Ship for CFD Validation Database (CFD 검증용 데이터베이스 구축을 위한 손상 선박의 횡동요 감쇠 운동에 대한 실험적 연구)

  • Lee, Sung-Kyun;You, Ji-Myoung;Lee, Hyun-Ho;Rhee, Shin-Hyung;Rhee, Key-Pyo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.1
    • /
    • pp.52-59
    • /
    • 2012
  • Among many factors to be considered for higher safety level requirements, the hull stability in intact and damaged conditions in seaways is of utmost importance. Since the assessment of a damaged ship is complicated due to the highly non-linear behavior, it is widely acknowledged that computational fluid dynamics (CFD) methods are one of the most feasible approaches. Although many research activities are being reported on the damaged ship stability recently, most of them are not designed for validation of CFD studies. In this study, well-designed model tests were performed to build a CFD validation database, which is essential in developing better CFD methods for the damage stability assessment. The geometry of the damaged compartment and test conditions were determined based on preliminary CFD simulations. Free roll decay tests in calm water with both intact and damaged ships were performed and the roll motion characteristics were compared. The damaged ship showed a larger roll damping coefficient and more rapid decrease of roll amplitude than the intact ship. The primary reason of these efforts can be explained by the movement of the flooded water.

Development of ACBIO: A Biosphere Template Using AMBER for a Potential Radioactive Waste Repository (AMBER를 이용한 방사성폐기물처분장 생태계 평가 템플릿 ACBIO 개발)

  • Lee Youn-Myoung;Hwang Yongsoo;Kang Chul-Hyung;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.213-229
    • /
    • 2005
  • Nuclides in radioactive wastes are assumed to be transported in the geosphere by groundwater and probably discharged into the biosphere. Quantitative evaluation of doses to human beings due to nuclide transport in the geosphere and through the various pathways in the biosphere is the final step of safety assessment of the radioactive waste repository. To calculate the flux to dose conversion factors (DCFs) for nuclides appearing at GBIs with their decay chains, a template ACBIO which is an AMBER case file based on mathematical model for the mass transfer coefficients between the compartments has been developed considering material balance among the compartments in biosphere and then implementing to AMBER, a general and flexible software tool that allows to build dynamic compartment models. An illustrative calculation with ACBIO is shown.

  • PDF

Effects of Temperature on the Pharmacokinetics of Ciprofloxacin in the Cultured Black Rockfish (Sebastes schlegeli) and Olive Flounders (Paralichthys olivaceus)

  • Kim Jin Woo;Jo Mira;Jung Sung Hee;Jee Bo Young;Choi Dong Lim;Jo QTae
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.3
    • /
    • pp.200-205
    • /
    • 2002
  • Temperature-dependent pharmacokinetics of ciprofloxacin (CIP) was studied in the cultured olive flounders, Paralichthys olivaceus, and black rockfish, Sebastes schlegeli using high performance liquid chromatography (HPLC) originally developed for quinolone determination from livestock. Pharmacokinetics of CIP was apparently affected by ambient water temperature. In a two-compartment model for flounders after oral dosage of 20 mg/kg, $K_{01},\;at\;13^{\circ}C$ and $23^{\circ}C$ were 4.18 and 1.20/hr, respectively. The $K_{10},\;T_{max}\;and\;C_{max}\;at\;13^{\circ}C$ were 5.574/hr, l4.37${\mu}g/mL\;and\;3.15{\mu}g/mL,$ respectively. The corresponding values at $23^{\circ}C$ were l2.84/hr, 15.39${\mu}g/mL\;and\;6.38{\mu}g/mL$, respectively. The AUC, $T_{1/2} (\alpha)\;and\;T_{1/2}\;(\beta)$ were 278.23 ${\mu}g \cdot hr/mL$, 0.24hr and 47.02hr at $13^{\circ}C$ and 3l7.8l${\mu}g \cdot hr/mL$, 0.30 hrs and 60.78hrs at $23^{\circ}C$ for the flounder, respectively. Similar CIP pharmacokinetics were revealed in the black rockfish after oral dosage of 20 mg/kg under the two water temperature regimes. These pharmacokinetical results have some implication in the optimal usage of recently introduced antibacterials in the farmed fish, which were primarily adapted for poultry and mammalian species.

Consideration of the benefits of using a high current accelerator in BNCT

  • Cho, Ilsung;Min, Sun-Hong;Park, Chawon;Kim, Minho;Lee, Kyo Chul;Lee, Yong Jin;Hong, Bong Hwan;Lim, Sang Moo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.10-19
    • /
    • 2020
  • Boron Neutron Capture Therapy (BNCT) has the advantage of selectively removing cancer cells ingesting boron compounds. In this study, the benefits for treatment time and boron compound injection dose were compared between current neutron sources and a high current neutron sources to be developed in near future. The time-activity curve (TAC) of GBM (Glioblastoma) for one bolus injection was obtained by applying modified 3 compartment model. The treatment time was determined for an accelerator-based neutron sources at the present time and a high current accelerator based neutron source to be developed in the near future. In the case of the double amount of IAEA-recommended neutron flux, the treatment time was shortened to 15 minutes. In the case of high current accelerators, which are five times the amount of IAEA-recommended neutron flux, the irradiation time is within 5 minutes. The use of a high current accelerator based neutron source in BNCT is advantageous in terms of treatment time. In addition, it can increase the efficiency of use of neutrons and reduce the boron compound injection dose to patients, thus reducing pharmacological toxicity.

Designing FMH Impact-Absorbing Structure by Using Subcomponent Collapse Simulation (단품 압궤 시뮬레이션을 이용한 FMH 충격흡수부재의 설계방법에 관한 연구)

  • Kim, Ji-Hun;Jun, In-Ki;Choi, Jae-Min;Kim, Sung-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1113-1118
    • /
    • 2010
  • It is requested that the interior compartment of a passenger vehicle must be satisfied with the FMVSS201U regulation, FMH impact test. It is needed the design methodology to find the appropriate structure about the FMH impact. When designing the impact-absorbing structure for the FMH impact test, it is to be noted that the impact absorber must have different performance considering the stiffness of the vehicle as the impact position and approach angle of FMH. In this study, an efficient design methodology was developed by using subcomponent collapse simulation instead of conducting full-vehicle simulation, thereby reducing the time and resources spent. Further, this unit-model simulation helps optimize the impact absorbing structure.

Pharmacokinetics of a New PEG-hemoglobin SBI for Single Intravenous Administration to Rats (흰쥐에 있어서 PEG-헤모글로빈 SBI의 단회정맥투여 약물동태)

  • 신호철;심희옥;유승룡;김종춘;양승돈;정문구
    • YAKHAK HOEJI
    • /
    • v.44 no.3
    • /
    • pp.232-236
    • /
    • 2000
  • An intravenous pharmacokinetics for a new red cell substitute, PEG-hemoglobin SB1, was studied in SD rats. Total-hemoglobin and its metabolite methemoglobin in the plasma were determined using a spectrophotometer. The limit of quantitation was 0.01g/dL and the C.V for interday assay reproducibility was less than 6%. Upon intravenous administration of anticipated clinical dose, 10 ml(0.7 gHb)/kg, plasma concentration curve of total-hemoglobin was well described by one-compartment model. The $t_{\frac{1}{2}},{\;}CL_{t}$, Vd and $AUC^{0-48hr}$ were $8.23{\pm}0.96{\;}hr,{\;}0.06{\;}{\pm}{\;}0.01 {\;}dL/hr/kg,{\;}0.66{\pm}0.05{\;}dL/lg{\;}and{\;}13.6{\;}{\pm}{\;}1.01g{\cdot}hr/dL$, respectively, in male rats(n=5, $mean{\;}{\pm}{\;}SD$). Those parameters in female rats were $9.21{\;}\pm{\;}2.31{\;}hr,{\;}0.06{\;}{\pm}{\;}0.01{\;}dL/hr/kg,{\;}0.79{\pm}{\;}0.08{\;}dL/kg{\;}and{\;}13.0{\;}{\pm}{\;}2.36{\;}g{\cdot}hr/dL$, respectively. Similar kinetic profiles between males and females were also obtained from other parameters. Small amount of methemoglobin, an oxidative metabolite of SB1, was detected in the plasma of both sexes, where the $AUC^{0-48{\;}hr,m}$ and $t_{{\frac{1}{2}},m}$ were approximately $1.5{\;}g{\cdot}hr/dL$ and 20 hr, respectively. The present work provides a critical kinetic data for the effective clinical applications of PEG-hemoglobin SB1.

  • PDF

An Experimental and Numerical Study on Fire Suppression Using a Mid-low Pressure Water Mist in a Carriage Fire (중저압 물분무를 이용한 객차내 화재진압에 관한 실험 및 수치해석적 연구)

  • Roh Jae-Seong;Yang Seung-Shin;Kim Dong-Hyun;Jung Woo-Sung;Jang Yong-Jun;Ryou Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.3 s.34
    • /
    • pp.291-297
    • /
    • 2006
  • The present study investigated the effect of fire suppression using a mid-low pressure water mist in a carriage fire. The fire extinguishing time and temperature distributions below ceiling in the enclosed compartment of $2.9m{\times}2.8m{\times}5.0m$ were measured by stopwatch and k-type thermocouples for various fire positions. The numerical simulations were extensively performed using. Fire Dynamics Simulator(FDS, Ver. 4.0) code and the predictions were compared with experimental data. The prediction results showed good agreement with the measured maximum temperature in the all cases. Whereas the predicted temperature was about $40^{\circ}C$ higher than the measured one after operating of water mist. The predicted fire extinguishing times were compared with those of measured data. Fires are extinguished within 200 seconds at the experiment in Case 2 and Case 3. But in Case 1 fire was not extinguished in the numerical simulation. The reason of the discrepancy between predicted and measured data was that a simple suppression algorithm has been implemented in FDS. Also, various databases of fire properties for combustible materials and more elaborate model considering the water mist were required fur better predictions of the cooling and suffocation effect.

Management Efficiency of Forest Tending Works by Using Data Envelopment Analysis (DEA(Data Envelopment Analysis)기법을 이용한 숲가꾸기 사업의 경영 효율성 분석)

  • Woo, Hee Sung;Woo, Jong Choon;Won, Hyun Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.4
    • /
    • pp.729-736
    • /
    • 2012
  • Korea Forest Service is recently focused on forest tending works for promoting in green jobs. The purpose of forest tending work is not only maintaining ecologically stable forest stand structure but also developing commercial forest. These trends are also emphasized by creation of various benefits and expanding carbon absorption in forest management. For achieving these purposes, Management efficiency of output was analized by the inputs such as labor cost, material cost and expense cost using DEA technique. The results show that, 19 sub-compartments are appeared to be the optimal in the efficiency of the forest tending works among total 52 sub-compartments. Among those there were 5 sub-compartment 8-0-3, 9-3-3, 6-0-3, 7-0-6, 1-0-5 and 3-0-3 to be considered in the high reference. The high reference areas mean those areas which is well accomplished in forest tending works as the desirable model.