• Title/Summary/Keyword: Compartment Model

Search Result 313, Processing Time 0.023 seconds

Pharmacokinetics of ciprofloxacin in chickens (닭에서 ciprofloxacin의 체내 동태에 관한 연구)

  • Kang, Hwan-goo;Cho, Myung-haing;Lee, Hang;Han, Myung-guk;Son, Seong-wan;Kim, Jae-hak;Lee, Jae-jin
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.471-480
    • /
    • 1995
  • The purpose of this experiment was to develop a simple and reliable HPLC method for the detection of ciprofloxacin in chicken serum and to provide a basic data on pharmacokinetic parameters after oral and intramuscular administration. The results obtained were as follows: 1. 0.2% meta-phosphoric acid: acetonitrile(7:3, v/v) solution had a high and regular recovery rates and was selected as an extraction solution. 2. The recovery rates of ciprofloxacin were 83-97% with the selected solution in chicken serum and the detection limit was 50ng/ml in serum. 3. Ka(abosorption rate constant) were 3.652 1/h in fasted group and 0.880 1/h in non-fasted group, and Ke (elimination rate constant) were 0.061 1/h and 0.133 1/h, respectively. 4. The highest concentration in serum after intramuscular injection was 840ng/ml within 15-30min and 160-324ng/ml in 1.1-3.2 hours after oral administration. 5. The time course of blood concentration fits well into a 2 compartment model. 6. On oral administration of ciprofloxacin with feed, ciprofloxacin was absorbed more slowly and the amount of absorbed was smaller than that of in fasted chickens. 7. Blood concentration of ciprofloxacin increased in a dose-dependent manner after intramusclular and oral administraiton.

  • PDF

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

Development and Assessment of a Dynamic Fate and Transport Model for Lead in Multi-media Environment

  • Ha, Yeon-Jeong;Lee, Dong-Soo
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • The main objective was to develop and assess a dynamic fate and transport model for lead in air, soil, sediment, water and vegetation. Daejeon was chosen as the study area for its relatively high contamination and emission levels. The model was assessed by comparing model predictions with measured concentrations in multi-media and atmospheric deposition flux. Given a lead concentration in air, the model could predict the concentrations in water and soil within a factor of five. Sensitivity analysis indicated that effective compartment volumes, rain intensity, scavenging ratio, run off, and foliar uptake were critical to accurate model prediction. Important implications include that restriction of air emission may be necessary in the future to protect the soil quality objective as the contamination level in soil is predicted to steadily increase at the present emission level and that direct discharge of lead into the water body was insignificant as compared to atmospheric deposition fluxes. The results strongly indicated that atmospheric emission governs the quality of the whole environment. Use of the model developed in this study would provide quantitative and integrated understanding of the cross-media characteristics and assessment of the relationships of the contamination levels among the multi-media environment.

Model for predicting the $^{137}C_s$ contamination of an agricultural plant following a soil deposition (토양침적에 의한 $^{137}C_s$ 농작물 오염평가 모델)

  • Jun, In;Keum, Dong-Kwon;Kang, Hee-Seok;Choi, Yong-Ho;Lee, Han-Soo;Lee, Chang-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.365-372
    • /
    • 2006
  • A dynamic compartment model is presented to predict the contamination level of agricultural plant by $^{137}C_s$ as a result of a soil deposition. The model considered the processes of a percolation, soil mixing by a plowing before transplanting, plant uptake, leaching to a deep soil, and fixation to a clay mineral. The effects of the soil properties (pH, clay mineral, organic matter content, and exchangeable K), which are spatially varied, on a plant uptake and the leaching rates of $^{137}C_s$ in a root zone soil were modeled by the Absalom model. To test the validity of the model, the $^{137}C_s$ aggregated transfer factors(TFa) for rice plants were compared with those observed from some simulated $^{137}C_s$ soil deposition experiments, which were carried out with respect to rice plants cultivated in seventeen paddy soils of different properties for two consecutive years. Observed $^{137}C_s$ TFa values of the rice plants did not show an evident trend for the pH and clay content of the soil properties, while they increased with an increasing organic matter content or a decreasing exchangeable K concentration. Predicted $^{137}C_s$ TFa values of the rice plants were found to be comparable with those observed.

  • PDF

A Nuclide Transport Model in the Fractured Rock Medium Using a Continuous Time Markov Process (연속시간 마코프 프로세스를 이용한 균열암반매질에서의 핵종이동 모델)

  • Lee, Y.M.;Kang, C.H.;Hahn, P.S.;Park, H.H.;Lee, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.529-538
    • /
    • 1993
  • A stochastic way using continuous time Markov process is presented to model the one-dimensional nuclide transport in fractured rock matrix as an extended study for previous work [1]. A nuclide migration model by the continuous time Markov process for single planar fractured rock matrix, which is considered as a transient system where a process by which the nuclide is diffused into the rock matrix from the fracture may be no more time homogeneous, is compared with a conventional deterministic analytical solution. The primary desired quantities from a stochastic model are the expected values and variance of the state variables as a function of time. The time-dependent probability distributions of nuclides are presented for each discretized compartment of the medium given intensities of transition. Since this model is discrete in medium space, parameters which affect nuclide transport could be easily incorporated for such heterogeneous media as the fractured rock matrix and the layered porous media. Even though the model developed in this study was shown to be sensitive to the number of discretized compartment showing numerical dispersion as the number of compartments are decreased, with small compensating of dispersion coefficient, the model agrees well to analytical solution.

  • PDF

Physiological Pharmacokinetic Model of Ceftriaxone Disposition in the Rat and the Effect of Caffeine on the Model

  • Kwon, Kwang-Il;Bourne, David-W.A.
    • Archives of Pharmacal Research
    • /
    • v.13 no.3
    • /
    • pp.227-232
    • /
    • 1990
  • A Physiologically based pharmacokinetic model was used to describe the distribition and elimination of cefriazone in the rat. To validate the practical application of the model, the effect of cffeine on the model was also examined. The model consisted of eleven compartments representing the major sites for ceftriaxone distribution including carcass which served as a residual compartment. Elimination was represented by renal and hepatic (metabolic biliary )excretion with GI secretion and re-absorption. The drug concentrations in most of the tissues were simulated using flow limited equations while brain levels were simulated using membrane limited passive diffusion distribution. The experimental data were obtained by averaging the concentration of drug in the plasma and tissues of five rats after i. v. injection of cefriazone 100 mg/kg without and with caffeine 20 mg/kg. The data for the amount of ceftriazone excreted in urine and gut contents were used to apportion total body clearance. HPLC with UV detection was used for the assay with 0.1-0.2 $\mu$g/ml sensitivity. The great majority of drug concentrations with and without caffeine show reasonably good agreements to the simulation results within 20%. The effect of caffeine on renal and hepatic clearances was apparent with 18.8% and 18.6% increase in the model values, respectively.

  • PDF

Scale Effect Analysis of LNG Cargo Containment System Using a Thermal Resistance Network Model (열저항 네트워크 모델을 이용한 LNG 화물창 Scale Effect 분석)

  • Hwalong You;Taehoon Kim;Changhyun Kim;Minchang Kim;Myungbae Kim;Yong-Shik Han;Le-Duy Nguyen;Kyungyul Chung;Byung-Il Choi;Kyu Hyung Do
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.222-230
    • /
    • 2023
  • In the present work, the scale effect on the Boil-Off Rate (BOR) was investigated based on an analytical method to systematically evaluate the thermal performance of a Liquefied Natural Gas (LNG) Cargo Containment System (CCS). A two-dimensional thermal resistance network model was developed to accurately estimate the heat ingress into the CCS from the outside. The analysis was performed for the KC-1 LNG membrane tank under the IGC and USCG design conditions. The ballast compartment of both the LNG tank and cofferdam was divided into six sections and a thermal resistance network model was made for each section. To check the validity of the developed model, the analysis results were compared with those from existing literature. It was shown that the BOR values under the IGC and USCG design conditions were agreed well with previous numerical results with a maximum error of 1.03% and 0.60%, respectively. A SDR, the scale factor of the LNG CCS was introduced and the BOR, air temperature of the ballast compartment, and the surface temperature of the inner hull were obtained to examine the influence of the SDR on the thermal performance. Finally, a correlation for the BOR was proposed, which could be expressed as a simple formula inversely proportional to the SDR. The proposed correlation could be utilized for predicting the BOR of a full-scale LNG tank based on the BOR measurement data of lab-scale model tanks.

A Development of Data Structure and Mesh Generation Algorithm for Global Ship Analysis Modeling System (선박의 전선해석 모델링 시스템을 위한 자료구조와 요소생성 알고리즘 개발)

  • Kim I.I.;Choi J.H.;Jo H.J.;Suh H.W.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • In the global ship structure and vibration analysis, the FE(finite element) analysis model is required in the early design stage before the 3D CAD model is defined. And the analysis model generation process is a time-consuming job and takes much more time than the engineering work itself. In particular, ship structure has too many associated structural members such as stringers, stiffness and girders etc. These structural members should be satisfied as the constraints in analysis modeling. Therefore it is necessary to support generation of analysis model with satisfying these constraints as an automatic manner. For the effective support of the global ship analysis modeling, a method to generate analysis model using initial design information within ship design process, that hull form offset data and compartment data, is developed. In order to easily handle initial design information and FE model information, flexible data structure is proposed. An automatic quadrilateral mesh generation algorithm using initial design information to satisfy the constraints imposed on the ship structure is also proposed. The proposed data structure and mesh generation algorithm are applied for the various type of vessels for the usability test. Through this test, we have verified the stability and usefulness of this system including mesh generation algorithm.

ANALYSIS OF FIRE CHARACTERISTICS IN APARTMENT BUILDING THROUGH FULL SCALE EXPERIMENT AND ZONE MODEL SIMULATION

  • Yoon, Myong-O;Park, Jin-Kook;Kim, Choong-Ik;Ryou, Hong-Sun;Kim, Jin-Gon;Kim, Myung-Bae;Choi, Jun-Seok;Kim, Kwang-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.413-422
    • /
    • 1997
  • Fire characteristics of a typical apartment building in Korea was studied through full scale experiment and zone model simulation. The fire was ignited at the living room and allowed to spread to other parts of a single unit in a five storied apartment building. Various data including temperatures, species concentrations, and images were collected in the experiment. A zone model(CFAST) was used to analyze the same apartment building that represents the average households in Korea. The results were compared with a full scale experiments. While CFAST allows one compartment involved with fire, the experiment allowed the fire to spread to other compartments. Therefore, the comparison between experimental data and Zone-Model data is valid until the living-room fire spread to other parts of the apartment. Flashover occurred at approximately 380 seconds in a fire experiment, and at approximately 420 seconds in Zone-Model. Based on all of data between experimental data and Zone-Model data, it is concluded that the safe escape time is about 250 seconds.

  • PDF

Risk Assessment of Indoor Pollution by BTEX Released from Groundwater (지하수내 BTEX에 의한 실내오염시 위해도 평가)

  • 유동한;이한수;김상준;양지원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.373-381
    • /
    • 2002
  • Benzene, Ethyl-benzene, Toluene and Xylene (BTEX) can be released to a groundwater in case of the oil leakage from underground storage tank of a gas station. These chemicals are found to contribute to the total inhalation risk from contaminated indoor air. This study presents the assessment of a human exposure to such chemicals released from the groundwater into indoor air. At first, a 2-compartment model is developed to describe the transfer and distribution of the chemicals released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such BTEX for adults based on two sets of exposure scenarios. Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor pollution by BTEX released from contaminated groundwater.