• 제목/요약/키워드: Comparison of radioactivity measurement

검색결과 22건 처리시간 0.024초

갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가 (The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement)

  • 이현국;강현수;양승오;한만석
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

Comparison of Environmental Radiation Survey Analysis Results in a High Dose Rate Environment Using CZT, NaI(Tl), and LaBr3(Ce) Detectors

  • Sungyeop Joung;Wanook Ji;Eunjung Lee;Young-Yong Ji;Yoomi Choi
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.543-558
    • /
    • 2023
  • Currently, Japan is undertaking a nationwide project to measure and map radioactive contamination around Fukushima, as part of the efforts to restore normalcy following the nuclear accident. The Japan Atomic Energy Agency (JAEA) manages the Fukushima Environmental Safety Center, located approximately 20 km north of the Fukushima Daiichi nuclear power plant in Minamisōma City, Fukushima Prefecture. In collaboration with the JAEA, this study involved conducting comparison experiments and analyses with radiation detectors in high radiation environments, a challenging task in Korean environments. Environmental radiation surveys were conducted using three types of detectors: CZT, NaI(Tl), and LaBr3(Ce), across two contaminated areas. Dose rate values were converted using dose rate conversion factors for each detector type, and dose rate maps were subsequently created and compared. The detectors yielded similar results, demonstrating their feasibility and reliability in high radiation environments. The findings of this study are expected to be a crucial reference for enhancing the verification and supplementation of procedures and methods in future radiation measurements and mobile surveys in high-radiation environments, using these three types of radiation instruments.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

원전주변 환경방사능 분석기술의 개선(I) (An Improvement on the Analysis Techniques of Environmental Radioactivity Around Nuclear Power Plants)

  • 김숭평;채경선;정운관
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.8-15
    • /
    • 1995
  • 환경방사능 분석기술은 원자력시설의 가동중 정상 및 비정상 상태시 이상판단과 지역특성에 따른 주변환경 방사능의 특성 및 거동파악 등을 하는데 필요한 기술로 원전 가동전, 후 환경방사능량을 비교함으로서 방사능 오염 및 변화상황을 파악할 수 있다. 국내에는 현재 관련법에 따라 규제기관 및 관련기관에 의해 환경감시가 계속되어오고 있으나 분석기술에 대한 한국규격이 없으므로 분석절차가 서로 상이하고 분석결과의 상대오차율이 커서 환경방사선 감시결과에 대한 신뢰성이 떨어지고 있다. 따라서 토양시료에 대한 감마핵종 분석에 한정하여 기수행된 측정방법 및 결과 둥을 비교분석하므로서 원전주변 환경방사능 감시목적에 적합한 분석기술의 신뢰도 향상 및 상대오차율 최소화 방안을 도출하였다

  • PDF

Choline-Lipid Release from Normal and Transformed Cells

  • Hong, Seong-Tshool;Jang, Yong-Suk;Park, Kie-In
    • BMB Reports
    • /
    • 제29권1호
    • /
    • pp.73-80
    • /
    • 1996
  • The effect of albumin on phosphatidylcholine (PC) metabolism in Hep-G2, 3T3-H.ras, and 3T3 cells pre-labelled with [Me-$^3H$]choline was studied. The [$^3H$]choline was more efficiently taken up and incorporated into cellular phospholipids in 3T3-H.ras cells than in Hep-G2 and 3T3 cells. In each of the three cell lines, most of the [$^3H$]choline metabolized into the phospholipids was incorporated into PC and only minor was incorporated into lysophosphatidylcholine (LPC). Bovine serum albumin stimulated the release of [$^3H$]LPC and [$^3H$]PC from each of the three cell lines pre-labelled with [$^3H$]choline. [$^3H$]PC was also released in the absence of albumin but [$^3H$]LPC was not. The efficiency of LPC secretion represented as the proportion of medium [$^3H$]LPC to cellular [$^3H$]choline lipid during a chase period is approximately 9 to 14 times greater in 3T3 cells compared with the transformed 3T3-H.ras and Hep-G2 cells. A similar comparison of published data for rat hepatocytes with Hep-G2 shows secretion to be 35~75 times greater from the rat hepatocytes than from Hep-G2. Also, PC secretion from 3T3 cells was 1.6 times more effective than from 3T3-H.ras, whereas rat hepatocytes secrete PC 2.8~3.8 times more effectively than does Hep-G2. The measurement of specific radioactivity of cellular PC in pre-labelled 3T3 cells showed it to be similar to that of the secreted PC. However, the specific radioactivity of secreted LPC was markedly lower than that of the cellular PC, which suggests that LPC is being secreted from a PC pool distinct from that used for PC secretion.

  • PDF

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정 (Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application)

  • 김창범;이상경;장성주;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.633-638
    • /
    • 2017
  • 방사선 진료기술의 발전에 따라 의료분야에서 발생하는 방사성폐기물이 급속히 증가하고 있다. 최근의 경향을 보면, 갑상선암 진료 목적의 I-131을 비롯하여 PET/CT 조영제로 사용하는 F-18, 핵의학검사에 폭 넓게 적용하는 Tc-99m 등의 방사성동위원소 사용이 일반화 되고 있다. 사용과정에서 이러한 핵종에 오염된 방사성폐기물이 발생하게 되는데, 일정기간 보관한 후에 방사능이 규제해제(Clearance) 수준으로 감쇠하면 소각 등의 방법으로 자체처분하게 된다. 국제원자력기구(IAEA)에서는 $10{\mu}Sv/y$의 개인선량 및 1man-Sv/y의 집단선량과 함께 핵종별 농도에 근거하여 방사성폐기물의 규제해제기준을 제시하였다. 이 연구에서는 IAEA의 핵종별 방사능농도기준에 따른 규제해제 시점을 확인하기 위하여, Tc-99m과 방사화학상유사한 성질을 가지고 있는 Re-186 관련 방사성폐기물을 수집하여 방사능을 측정하였다. Re-186은 반감기가 3.8일로 방사성의약품으로는 비교적 길고, 베타선 및 감마선을 방출하여 방사성의약품 치료와 영상에 모두 사용된다. Re-186 사용과 관련하여 발생하는 오염된 일회용장갑(Poly Glove)의 방사능측정을 위하여 다중파고분석기(Multi Channel Analyzer; MCA)를 이용하였으며, 이를 위하여 표준물질을 제작하여 MCA를 교정한 이후 감마방사능 측정절차에 따라 수행하였다. 측정결과를 근거로 방사능 감쇠 유도식을 산출하여 이론식과 대비하여 고찰하였는바, Re-186 핵종의 유도반감기(3.6일)는 이론적 반감기(3.8일)에 비해 다소 짧은 것으로 나타났다. 따라서 측정결과에 근거한 유도반감기를 적용한다면, 다소 줄어든 기간 동안 Re-186 핵종 폐기물을 보관하였다가 자체처분을 할 수 있을 것으로 확인하였다. 이 연구 결과는 현재 추진하고 있는 국제표준화기구(International Organization for Standardization) 국제표준에 포함될 예정이다.

PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교 (Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images)

  • 김영재;박훈희;이주영;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

충전후 방사능에 의한 변연누출 측정에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A RADIOACTIVITY)

  • 김미자;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.69-78
    • /
    • 1988
  • The study was designed to establish a more nearly quantitative method for assessing the marginal leakage of dental restorations. 27 Class V cavities with $45^{\circ}$ bevel joint were prepared and classified into 2 groups. One group was filled with Scotchbond and silux. The other group was filled with glass ionomer cement, Scotchbond and silux. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ water-bath. They were soaked in a samarium nitrate solution for 3 hours, irradiated with flux of $6{\times}10^{12}$ neutrons/$cm^2$/sec for 11 hours, cooled for 200 hours, counted with the HPGE detector and the tracer uptake was determined by comparison with a standard of samarium (10 ${\mu}g$). The following results were obtained. 1. Both of the two groups showed a considerable amounts of marginal leakage. 2. The group filled without glass ionomer cement base showed more marginal leakage than the group filled with glass ionomer cement base. 3. Neutron Activation Analysis produced a good quantitative method to measure the marginal leakage and samarium was appropriate to measure the marginal leakage of resin restorations using neutron activation analysis.

  • PDF