• Title/Summary/Keyword: Comparison of camera's image quality

Search Result 11, Processing Time 0.023 seconds

Research of the Objective Quality Comparison of Underwater Cameras (수중 촬영용 카메라의 객관적 화질 비교에 관한 연구)

  • Ha, Yeon-Chul;Park, Jun-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.92-100
    • /
    • 2020
  • Currently, the demand for underwater or underwater photography is growing very fast. Its coverage of underwater shooting for broadcasting, leisure and sports, and military and operational use is also growing rapidly. Among them, we specifically select the best camera to be used in underwater drones to photograph and inspect marine life attached to the ship's hull. To compare three cameras performance, they are compared and evaluated using objective and subjective criteria in special circumstances such as underwater shooting. This study checks whether performance criteria, such as resolution of a camera, meet objective and subjective standards in the unusual situation of underwater shooting. And it shows that in addition to the filter that calibrates the image, proper camera selection is important for providing good picture quality. Even after this study, research using more diverse cameras could provide an appropriate standard for comparison of underwater camera quality.

THE ADVANTAGE OF ON ORBIT NON-UNIFORMITY CORRECTION FOR MULTI SPECTRAL CAMERA (MSC)

  • Chang Young-Jun;Kong Jong-Pil;Huh Haeng-Pal;Kim Young-Sun;Park Jong-Euk
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.586-588
    • /
    • 2005
  • The MSC (Multi Spectral Camera) system is a remote sensing payload to obtain high resolution ground image. This system uses lossy image compression method for &Direct mission& that transmit whole image during one contact. But some image degradation occurred especially at high compression ratio. To reduce this degradation, the MSC uses NUC (Non-uniformity Correction) Unit. This unit correct CCD (Charge Coupled Device)'s high-frequency non-uniformity. So high frequency contents of image can be minimized and whole system SNR can be maximized. But NUC has some disadvantage either. It decreases entire system reliability by adding one electronic system. Adding NUC also led to difficulty of electronic design, assembly and testability. In this paper, the comparison is performed between on-orbit non-uniform correction and on ground correction. by evaluating NUC advantage for the point of view of image quality. Using real MSC parameter and proper model, considerable reference point for the system design came to possible.

  • PDF

Design of Off-axis Wide Angle Lens for the Automobile Application

  • Kim, Tae Young;Shin, Min-Ho;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.336-343
    • /
    • 2013
  • Recently various types of driver assistance systems have been used for automobiles. In 2008, the U.S Congress passed a law which required that most cars be equipped with devices to warn objects behind the vehicle. Because of that, market of rear view cameras is expected to rise dramatically. Therefore many suppliers try to provide a wide angle camera for car makers. But a high distortion is caused by the wide angle might result in lower image quality. In order to improve the image quality, normally we use an algorithm to correct a distortion. Though we can improve the distorted image by correction algorithm, we must pay more cost to use it. In this paper, we propose a new optical system reducing a distortion in contrast to a conventional lens without cost. In other words, we can see only an area of interest. That is similar to reducing a field of view. Using a new optical system, we can get a less distorted image. In order to view an area of interest, we introduce an off axis optical system having refractive surfaces and reflective surfaces. In this paper, we describe the results of design and, evaluation of an off axis wide angle compact imaging system. In comparison to conventional wide angle lens, we can get the improvement of MTF, distortion, and lateral color aberrations. And we also can reduce a total cost because we don't need the outer apparatus or bracket to mount on the car.

Development of vision system for quality inspection of automotive parts and comparison of machine learning models (자동차 부품 품질검사를 위한 비전시스템 개발과 머신러닝 모델 비교)

  • Park, Youngmin;Jung, Dong-Il
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.409-415
    • /
    • 2022
  • In computer vision, an image of a measurement target is acquired using a camera. And feature values, vectors, and regions are detected by applying algorithms and library functions. The detected data is calculated and analyzed in various forms depending on the purpose of use. Computer vision is being used in various places, especially in the field of automatically recognizing automobile parts or measuring the quality. Computer vision is being used as the term machine vision in the industrial field, and it is connected with artificial intelligence to judge product quality or predict results. In this study, a vision system for judging the quality of automobile parts was built, and the results were compared by applying five machine learning classification models to the produced data.

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A Surface Image Velocimetry Algorithm for Analyzing Swaying Images (흔들리는 영상 분석을 위한 표면 영상 유속계 알고리듬)

  • Yu, Kwonk-Yu;Yoon, Byung-Man;Jung, Beom-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.855-862
    • /
    • 2008
  • Surface Image Velocimetry (SIV) is an instrument to measure water surface velocity by using image processing techniques. To improve its measuring accuracy, it is essential to get high quality images with low skewness. A truck-mounted SIV system would be a good way to get images, since its crane gives high altitude to the images. However, the images taken with a truck-mounted SIV would be swayed due to the movement of crane and the camera by winds. In that case, to analyze the images, it is necessary to compensate the side sway in the images. The present study is to develop an algorithm to analyze the swayed images by combining common image processing techniques and coordinate transform techniques. The system follows the traces of some selected fixed points and calculates the displacements of the video camera. By subtracting the average velocity of the fixed points from that of grid points, the velocity fields of the flow can be corrected. To evaluate the system's performance, two image sets were used, one image set without side sway and another set with side sway. The comparison of their results showed very close with the error of around 6 %.

A study of Full Width at Half Maximum(FWHM) according to the Filter's Cut off level in SPECT camera (SPECT filter의 cut off level에 따른 반폭치(FWHM) 크기에 관한 연구)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2003
  • Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency supression by chosing a cut of frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimam cut off level with comparison of FWHM according to cut off level in each kiters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with $^{99m}TcO_4$ point source and measured FWHM by use profile curve. We find averaged length is $9.16\;mm{\sim}18.14\;mm$ of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  • PDF

A Study on Improving the Quality of DIBR Intermediate Images Using Meshes (메쉬를 활용한 DIBR 기반 중간 영상 화질 향상 방법 연구)

  • Kim, Jiseong;Kim, Minyoung;Cho, Yongjoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.822-823
    • /
    • 2014
  • The usual method of generating an image for a multiview display system requires acquiring a color image and depth information of a reference camera. Then, intermediate images, generated using DIBR method, will be captured at a number of different viewpoints and composed to construct an multiview image. When such intermediate views are generated, several holes would be shown because some hidden parts are shown when the screenshot is taken at different angle. Previous research tried to solve this problem by creating a new hole-filling algorithm or enhancing the depth information. This paper describes a new method of enhancing the intermediate view images by applying the Ball Pivoting algorithm, which constructs meshes from a point cloud. When the new method is applied to the Microsoft's "Ballet" and "Break Dancer" data sets, PSNR comparison shows that about 0.18~1.19 increasement. This paper will explaing the new algorithm and the experiment method and results.

  • PDF

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF