• Title/Summary/Keyword: Comparison Research

Search Result 15,347, Processing Time 0.048 seconds

Catching efficiency of biodegradable trammel net for swimming crab (Portunus trituberculatus) in the Yeonpyeong fishing ground of Korea (연평어장에서 생분해성 꽃게 삼중자망의 어획성능)

  • Kim, In-Ok;Lee, Gun-Ho;Cho, Sam-Kwang;Cha, Bong-Jin;Sohn, Byung-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.322-336
    • /
    • 2012
  • To study the catching efficiency of biodegradable trammel net for swimming crab (Portunus trituberculatus), three types (biodegradable, monofilament and multifilament) of trammel nets were used in the field test, and the tests were carried out 16 times with two different mesh sizes (105mm and 160mm) in the Yeonpyeong fishing ground of Korea, 2009~2011. The catching efficiency of three type nets was analyzed by catch in number, catch in weight and average weight per individual of small and large size swimming crab by net types and mesh sizes. Statistical T-test was also carried out to verify the efficiency between the three types of nets. The results are as follows. The catch in number of swimming crab was 24,667 and formed about 81.0% of total catch. Of all swimming crab catch, small swimming crabs with less than 64mm in carapace length which is a prohibited landing size by law formed 48.1%, larger swimming crabs with more than 64mm in carapace length which is a landing size formed 51.9%. In 105mm mesh size trammel net test, the catch share in number of small size swimming crab by biodegradable trammel net was 47.5% in comparison with multifilament trammel net and 74.2% in comparison with monofilament trammel net, so biodegradable trammel net has more protective effects on small size swimming crab than other types of trammel nets. The protective effects for small size swimming crab by biodegradable trammel net was 25.8~52.5% in comparison with other types of trammel nets. The catch share in weight of large size swimming crab by biodegradable trammel net was 98.3% in comparison with multifilament trammel net and 92.3% in comparison with monofilament trammel net, so biodegradable trammel net has a similar catch efficiency to multifilament trammel net. The results of 160mm mesh size trammel net test have shown similar results of 105mm mesh size trammel net test. This study shows that biodegradable trammel net is a more useful fishing gear than multifilament and monofilament trammel net because biodegradable trammel net has lower catch rate than other types of nets in small size swimming crab and similar catch rate than multifilament trammel net which is a well used net by fishermen.

The Rearch Of Method in the Appropriate number of Demand and Supply of OMD (한의사인력(韓醫師人力) 공급(供給)의 적정화방안(適定化方案) 연구(硏究))

  • Lee, Jong-Soo
    • The Journal of Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.299-326
    • /
    • 1998
  • 1. Comparison of demand and supply A. Assumption of estimation of demand and supply we will briefly assumptions used for presumption once more before comparing the result of estimation of demand and supply examined previously 1) supply - The average applying rate for state. examination of graduate: ${\alpha}$=1.03109 - The ratio of successful applicants of state examinations: ${\beta}$=0.97091 - Mortality classified by age : presumed data of the Bureau of statistics - Emigrating rate: 0 % - Time of retire: unconsidered - An army doctor number: unconsidered and regard number of employed oriental medicine doctor. - Standard of 1995 : The number of survival oriental medicine doctor is 8195. the number of employed oriental medicine doctor is 7419. 2) demand - derivated demand method Daily the average amount of medical treatment: according to medical insurance federation data. there is 16 or 6 non allowance patient, we consider amount of medical treatment as 22 persons in practical because 21.94 persons (founded practical examination) are converted to allowance in comming demand. Daily the proper amount of medical treatment: 7 hours form -35 persons 5 hours 30 minutes form -28 persons. Yearly medical treatment days: 229 days. 255 days. 269 days . Increasing rate of visiting hospital days: -1996 year. 1997 year. 1998 year- . Rate of applying insurance: yearly average 71.51% (among the investigated patient) B. Comparison of total sum result 1) supply (provision) Table Ⅳ-1 below shows the estimation of the oriental medicine doctor in the future.

  • PDF
  • Generation of Ionospheric Delay in Time Comparison for a Specific GEO Satellite by Using Bernese Software

    • Jeong, Kwang Seob;Lee, Young Kyu;Yang, Sung Hoon;Hwang, Sang-wook;Kim, Sanhae;Song, Kyu-Ha;Lee, Wonjin;Ko, Jae Heon
      • Journal of Positioning, Navigation, and Timing
      • /
      • v.6 no.3
      • /
      • pp.125-133
      • /
      • 2017
    • Time comparison is necessary for the verification and synchronization of the clock. Two-way satellite time and frequency (TWSTFT) is a method for time comparison over long distances. This method includes errors such as atmospheric effects, satellite motion, and environmental conditions. Ionospheric delay is one of the significant time comparison error in case of the carrier-phase TWSTFT (TWCP). Global Ionosphere Map (GIM) from Center for Orbit Determination in Europe (CODE) is used to compare with Bernese. Thin shell model of the ionosphere is used for the calculation of the Ionosphere Pierce Point (IPP) between stations and a GEO satellite. Korea Research Institute of Standards and Science (KRISS) and Koganei (KGNI) stations are used, and the analysis is conducted at 29 January 2017. Vertical Total Electron Content (VTEC) which is generated by Bernese at the latitude and longitude of the receiver by processing a Receiver Independent Exchange (RINEX) observation file that is generated from the receiver has demonstrated adequacy by showing similar variation trends with the CODE GIM. Bernese also has showed the capability to produce high resolution IONosphere map EXchange (IONEX) data compared to the CODE GIM. At each station IPP, VTEC difference in two stations showed absolute maximum 3.3 and 2.3 Total Electron Content Unit (TECU) in Bernese and GIM, respectively. The ionospheric delay of the TWCP has showed maximum 5.69 and 2.54 ps from Bernese and CODE GIM, respectively. Bernese could correct up to 6.29 ps in ionospheric delay rather than using CODE GIM. The peak-to-peak value of the ionospheric delay for TWCP in Bernese is about 10 ps, and this has to be eliminated to get high precision TWCP results. The $10^{-16}$ level uncertainty of atomic clock corresponds to 10 ps for 1 day averaging time, so time synchronization performance needs less than 10 ps. Current time synchronization of a satellite and ground station is about 2 ns level, but the smaller required performance, like less than 1 ns, the better. In this perspective, since the ionospheric delay could exceed over 100 ps in a long baseline different from this short baseline case, the elimination of the ionospheric delay is thought to be important for more high precision time synchronization of a satellite and ground station. This paper showed detailed method how to eliminate ionospheric delay for TWCP, and a specific case is applied by using this technique. Anyone could apply this method to establish high precision TWCP capability, and it is possible to use other software such as GIPSYOASIS and GPSTk. This TWCP could be applied in the high precision atomic clocks and used in the ground stations of the future domestic satellite navigation system.

    Inter-comparison of temperature measurement capability using standard platinum resistance thermometers (표준백금저항온도계를 이용한 온도측정능력 상호비교)

    • Gam, K.S.;Kang, C.S.;Lee, Y.J.;Lee, K.B.;Kim, Y.G.;Park, S.N.
      • Journal of Sensor Science and Technology
      • /
      • v.18 no.1
      • /
      • pp.86-94
      • /
      • 2009
    • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.