• Title/Summary/Keyword: Communicating segment

Search Result 14, Processing Time 0.018 seconds

Duplication of the Esophagus -Report of A Case- (식도중복증의 1례)

  • 홍기우
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.169-174
    • /
    • 1974
  • Duplication of the alimentary tract, especially of the esophagus, have been regarded as rare cong- enital anomalies. However, they are being reported with increasing frequency in the literature. In the . ,- past they have been described by a variety of names, such as "enteric cysts", "intestinal cysts", "giant diverticula", "`mediastinal cysts of foregut origin" "enterogenous cysts" and other descriptive terms. . Most authorities now agree that these anomalies are best described by the term "duplications of the alimentary tract. The duplications [of the alimentary tract] are spherical or tubular structures which poses a well developed smooth muscle layer and are lined with a mucous membrane from any part of the alimentary tract. They may occur at any place in the digestive tube from the tongue to the rectum and usually are intimately attached to some portion of the alimentary tube. We have experienced a duplication of the esophagus in 14 years old middle schoolboy. He complained dysphagia, eructation and substernal pain associated with intermittent high fever and chilliness, increasing in severity for recent three weeks. Routine chest X-ray film revealed nore markable abnormal finding but esophagogram. revealed marked narrowing of the esophagus throughout with a large blind pouch in lower half with fistulous communication at mid portion of the esophagus. On thoracotomy, a large infected blind pouch communicating with the lumen of normal esophagus proximally, Was extended from the level of 5th to 10th thoracic spine. The duplicated segment of the esophagus has a common muscular .wall and proximal communication with the adjacent esophagus. The infected, duplicated esophagus was segmentally resected, and esophagogastrostomy with pyloroplasty was done by displacing the stomach into the right thoracic cavity through midline laparotomy. His Postoperative course was uneventful and discharged without complication.

  • PDF

Delayed Diagnosis of Cerebral Infarction after Complete Occlusion of ICA due to Blunt Head Trauma: A Case of Report (두부둔상 후 내경동맥손상으로 인한 뇌경색의 지연진단: 증례보고)

  • Yun, Jung-Ho;Ko, Jung Ho;Cho, Chun-Sung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.190-194
    • /
    • 2015
  • Blunt cerebrovascular injury is defined as a vertebral or carotid arterial structural wall injury resulting from nonpenetrating trauma. Complete traumatic internal carotid artery occlusion is very rare condition accounting for 0.08~0.4 0f all trauma patients and believed to be associated with the greatest risk of ischemic stroke reported in 50~90% in a few small series. A 55-year-male was admitted with drowsy mentality and severe headache after a fall down accident. Brain computed tomography showed a subdural hematoma at the both frontal area with a fracture of the occipital skull bone. Two days after admission, he suddenly complained with a right side hemiparesis of motor grade 2. Brain magnetic resonance diffusion demonstrated multiple high flow signal changes from the left frontal and parietal lesion. Computed tomographic angiogram (CTA) revealed absence of the left ICA flow. Trans femoral cerebral angiography (TFCA) showed complete occlusion of the left internal carotid artery (ICA) at ophthalmic segment in the left ICA angiogram and flows on the left whole hemispheric lesions through the anterior communicating artery in the right ICA angiogram. We decided to conduct close observations as a treatment for the patient because of acute subdural hematoma and sufficient contralateral cerebral flow by perfusion SPECT scan. Two weeks after the accident, he was treated with heparin anticoagulation within INR 2~4 ranges. He recovered as the motor grade 4 without another neurologic deficit after 3 months.

  • PDF

Cardiac Troponin I Elevation in Patients with Aneurysmal Subarachnoid Hemorrhage

  • Jeon, Ik-Chan;Chang, Chul-Hoon;Choi, Byung-Yon;Kim, Min-Su;Kim, Sang-Woo;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.99-102
    • /
    • 2009
  • Objective: Cardiac dysfunction after aneurysmal subarachnoid hemorrhage (SAH) is associated with elevation of serum cardiac troponin I (cTnl) levels. Elevation of cTnl predicts cardiopulmonary and neurological complications, and poor outcome. Methods: We retrospectively reviewed the medical and radiologic records of 114 (male: 30, female: 84) patients who developed aneurysmal SAH between January 2006 and June 2007 and had no history of previous cardiac problems. We evaluated their electrocardiography and cTnl level, which had been measured at admission. A cTnl level above 0.5 $\mu$g/L was defined as an indicator of cardiac injury following SAH. We examined various clinical factors for their association with cTnl elevation and analyzed data using chi-square test, t-test and logistic regression test with SPSS version 12.0. The results were considered significant at p< 0.05. Results: The following parameters shows a correlation with cTnl elevation: higher Hunt-Hess (H-H) grade (p = 0.000), poor Glasgow Outcome Scale (GOS) score (p = 0.000), profound pulmonary complication (p = 0.043), higher heart rate during initial three days following SAH (p = 0.029), ruptured aneurysm on communicating segment of internal carotid artery (p = 0.025), incidence of vasospasm (p = 0.421), and duration of hyperdynamic therapy for vasospasm (p = 0.292). A significant determinants for outcome were cTnl elevation (p = 0.046) and H-H grade (p = 0.000) in a multivariate study. Conclusion: A cTnl is a good indicator for cardiopulmonary and neurologic complications and outcome following SAH. Consideration of variable clinical factors that related with cTnl elevation may be useful tactics for treatment of SAH and concomitant complications.

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF