• Title/Summary/Keyword: Common-Mode (CM)

Search Result 47, Processing Time 0.022 seconds

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

Studies on Salmonella isolated from chicks (초생추 유래 Salmonella속균의 생물학적 특성)

  • Oh, Gang-hee;Choi, Won-pil
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.501-510
    • /
    • 1994
  • This paper deals with the distribution, reservoir and mode of spread of infection on 6 hatcheries in Taegu, Kyungpook and 5 broiler farms in Kyungpook during the period from June 1991 to June 1992. Isolated Salmonella were examined for serotypes, biotyping of Salmonella(S) typhimurtum, antibiotic susceptibility and some biochemical characteristics. Forty two Salmonella strains were isolated from 42(2.7% of 1,577 caecal samples of chicks, and their serotypes were S typhimurium 10, S typhimurium var Copenhagen 5, S infantis 4, S thompson 3, and untypable 20. The isolation rate of Salmonella varied from 0 to 5.1% in 6 hatcheries and that of Salmonella from 5 broiler farms was 10. 5%. Biotypes of 10 S typhimurium and 5 S typhimurium var Copenhagen strains isolated from chicks of hatcheries and broiler farms were biotype 2(86.6%), 8(6.7%), and 10a(6.7%), and 26i(6.7%) according to Duguid's scheme. Antibiotic susceptibility test of Salmonella isolated were performed by agar dilution method, using 9 antibiotics as follows: ampicillin(Am), chloramphenicol(Cm), gentamicin(Gm), kanamycin(Km), nalidixic acid(Na), rifampicin(Rf), streptomycin(Sm), sulfadimethoxine(Su), and tetracycline(Tc), All the strains were sensitive to RF. But 8 strans(23.8%) were resistant to one or more drugs and the most common resistance patterns of transferred R plasmids were SmSuGm and SmSu. Among 42 isolates, one had transferable citrate utilizing plasmid. S typhimurium and S typhimurium var copenhagen strains were resistant to killing by 90% normal guinea pig serum.

  • PDF

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Influence of Atherosclerosis Risk Factors on Carotid Intima, Media, and Intima-Media thickness

  • Kim, Wuon-Shik;Bae, Jang-Ho;Jin, Seung-Hyun;Park, Yong-Ki;Noh, Gi-Yong;Hwang, Jae-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 2006
  • We intended to measure the IT, MT, and the IMT of carotid artery separately and tried to analyze the clinical significance. Two hundred and fifty consecutive patients (125 males, 125 females) underwent carotid artery scanning using high-resolution ultrasound. The images were off-line analyzed using B-mode ultrasound image processing, devised in our research. We measured the IT, MT, and IMT semi-automatically at the far wall of designated 1cm length of the right common carotid and calculated the average values over the 200 points. The IT (p < 0.05), MT (p < 0.05) as well as IMT (p < 0.01) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hypertension showed significantly thicker IT (p < 0.05), MT (p < 0.01), and IMT (p < 0.01) than that of the patients without hypertension. However, only IT was thicker in patients with smoking (p < 0.05) than that of the patients without smoking. Smoking was associated only with intima while hypertension was associated with the all three layer's thickness. This result suggests the atherosclerotic process can be different by cardiovascular risk factors.

  • PDF

Power Supply-Insensitive Gbps Low Power LVDS I/O Circuits (공급 전압 변화에 둔감한 Gbps급 저전력 LVDS I/O회로)

  • Kim, Jae-Gon;Kim, Sam-Dong;Hwang, In-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.6 s.360
    • /
    • pp.19-27
    • /
    • 2007
  • This paper presents power supply-insensitive Gbps low power LVDS I/O circuits. The proposed LVDS I/O has been designed and simulated using 1.8V, $0.18\;{\mu}m$ TSMC CMOS Process. The LVDS I/O includes transmitter and receiver parts. The transmitter circuits consist of a differential phase splitter and an output stage with the switched capacitor common mode feedback(SC-CMFB). The differential phase splitter generates a pair of differential signals which provides a balanced duty $cycle(50{\pm}2%)$ and phase difference$(180{\pm}0.2^{\circ})$ over a wide supply voltage range. Also, $V_{OD}$ voltage is 250 mV which is the smallest value of the permissible $V_{OD}$ range for low power operation. The output buffer maintains the required $V_{CM}$ within the permissible range$(1.2{\pm}0.1V)$ due to the SC-CMFB. The receiver covers a wide input DC offset $range(0.2{\sim}2.6\;V)$ with 38 mV hysteresis and Produces a rail-to-rail output over a wide supply voltage range. Beside, the designed receiver has 38.9 dB gain at 1 GHz, which is higher than conventional receivers.

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

A Study on the Characteristics Analysis of Hybrid Choke Coil with Reduced Parasitic Capacitance suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 기생 커패시턴스 저감형 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Lee, Jong-Hyeon;Kim, Gu-Yong;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.185-188
    • /
    • 2018
  • This paper describes the parasitic capacitance modeling according to the coil structure, section bobbin and winding method for hybrid choke coil with reduced parasitic capacitance capable of the EMI attenuation of broad bands from lower frequency to higher frequency applied in the EMI attenuation filter of LED-TV SMPS. Especially, the hybrid choke coil with reduced parasitic capacitance($C_p$) proposed in this paper can reduces the parasitic capacitance($C_p$) by adopting the winding methods of rectangular copper wire, compared to the conventional common mode choke coil with the winding method of automatic type. The first resonant frequency of the proposed hybrid choke coil has a tendency to increase as the parasitic capacitance is smaller and its impedance characteristics, especially in the high frequency bands, improves as the first resonant frequency increases. In the future, the proposed hybrid choke coil with reduced parasitic capacitance shows it can be actually utilized in not only LED-TV SMPS but also various applications such as LED Lighting, Note-PC Adapter, and so forth.