• Title/Summary/Keyword: Common-Mode (CM)

Search Result 47, Processing Time 0.028 seconds

Effect of Non-perceptual Sensory Stimulation Intensity Using Transcutaneous Electrical Nerve Stimulation on Cerebral Blood Flow (경피신경전기자극기를 이용한 비지각적 감각자극 강도가 뇌혈류에 미치는 영향)

  • Ju-Yeon Jung;Chang-Ki Kang
    • Science of Emotion and Sensibility
    • /
    • v.27 no.2
    • /
    • pp.81-90
    • /
    • 2024
  • In this study, we aimed to determine the effect on cerebral blood vessels of various stimulus intensities using transcutaneous electrical nerve stimulation (TENS). In particular, we wanted to monitor changes in blood flow and structural changes in the blood vessels in the common carotid artery (CCA) through low-intensity electrical stimulation that can cause non-perceptual sensory stimulation. Twenty-four healthy adults in their 20s participated in this study. Three stimulus intensities (below the sensory threshold, at the sensory threshold, and above the sensory threshold) were applied in random order. Changes in blood flow velocity according to the intensity of TENS stimulus were measured by placing the Doppler ultrasound transducer 1 cm below the CCA bifurcation, and the vascular structure was measured using B-mode imaging. C-mode Doppler and B-mode images were acquired before, during, and after the intervention for each stimulus, and changes in blood pressure were measured in each session. As a result, it was confirmed that peak systolic velocity (PSV) decreased significantly after the intervention in non-perceived sensory stimulation below the threshold, compared to other thresholds (p = .008). In particular, the PSV decreased by 3.04% on average compared to before stimulation (p = .011). However, there was no significant change in the CCA diameters before and after stimulation at all intensities. It was found that short-term, non-perceptual sensory stimulation was effective in reducing the blood flow rate without causing significant changes in either the blood vessel diameter or blood pressure. This change appears to be caused by a decrease in blood flow due to the effect of subtle vasodilation at non-perceptual sensory stimulation, and at stimulation intensity higher than that, the sympathetic nerves in the blood vessels are stimulated excessively and the blood vessels constrict. Therefore, this study can be rated as an important attempt to control blood flow through stimulation without such a psychological burden and sensory discomfort in the carotid area.

Modeling and Filter Design through Analysis of Conducted EMI in Switching Power Converters

  • Vimala, R.;Baskaran, K.;Aravind Britto, K.R.
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.632-642
    • /
    • 2012
  • This paper presents a filter analysis of conducted Electro-Magnetic Interference (EMI) in switching power converters (SPC) based on noise impedances. The EMI characteristics of SPC can be analytically deduced from a circuit theoretical viewpoint. The analytical noise model is investigated to get a full understanding of the EMI mechanism. It is shown that with suitable and justified model, filters pertinent to EMI noise is investigated. The EMI noise is identified by time domain measurements associated with an isolated half-bridge ac-dc converter. Practical filters like LC filter, ${\pi}$ filter and complete EMI filters are investigated. The proposed analysis and results can provide a guideline for improving the effectiveness of filtering schemes in SPC. Experimental results are also included to verify the validity of the proposed method. The results obtained satisfy the Federal Communications Commission (FCC) class A and class B regulations.

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

EMI Noise Source Reduction of Single-Ended Isolated Converters Using Secondary Resonance Technique

  • Chen, Zhangyong;Chen, Yong;Chen, Qiang;Jiang, Wei;Zhong, Rongqiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.403-412
    • /
    • 2019
  • Aiming at the problems of large dv/dt and di/dt in traditional single-ended converters and high electromagnetic interference (EMI) noise levels, a single-ended isolated converter using the secondary resonance technique is proposed in this paper. In the proposed converter, the voltage stress of the main power switch can be reduced and the voltage across the output diode is clamped to the output voltage when compared to the conventional flyback converter. In addition, the peak current stress through the main power switch can be decreased and zero current switching (ZCS) of the output diode can be achieved through the resonance technique. Moreover, the EMI noise coupling path and an equivalent model of the proposed converter topology are presented through the operational principle of the proposed converter. Analysis results indicate that the common mode (CM) EMI noise and the differential mode (DM) EMI noise of such a converter are deduced since the frequency spectra of the equivalent controlled voltage sources and controlled current source are decreased when compared with the traditional flyback converter. Furthermore, appropriate parameter selection of the resonant circuit network can increase the equivalent impedance in the EMI coupling path in the low frequency range, which further reduces the common mode interference. Finally, a simulation model and a 60W experimental prototype of the proposed converter are built and tested. Experimental results verify the theoretical analysis.

A New Bridgeless PFC Converter With Simple Gate Driving Circuit And High Efficiency for Server Power Application (게이트 구동회로가 간단하고 높은 효율을 가지는 새로운 형태의 브리지리스 PFC 컨버터에 관한 연구)

  • Lee, Young-Dal;Kim, Chong-Eun;Kim, Dong-Min;Choi, Seung-Hyun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.92-94
    • /
    • 2019
  • 양방향 스위치를 가지는 Bridgeless PFC 컨버터(BBPFC)는 구조상 복잡한 플로팅 게이트 드라이버를 활용함에도 불구하고 좋은 공통모드 잡음 즉, Common-Mode (CM) 노이즈 특성과 간단한 제어 방법으로 인해 많은 브리지리스 PFC 컨버터 중에서도 고전력 응용분야에서 매우 매력적인 토폴로지이다. 이러한 BBPFC는 도통 경로 상에 위치한 정류 다이오드의 역회복 특성의 상대적인 편차를 활용하여 전력 밀도를 감소시키지 않고도 좋은 공통모드 (CM) 노이즈 특성의 확보가 가능하다. 하지만 이러한 장점을 가지는 BBPFC 구조를 고전력 서버용 전원장치분야에서 활용할 경우, 이미 등록된 특허로 인해 매우 높은 개런티를 지불해야 하므로 그 활용이 매우 제한적이다. 따라서, 본 논문에서는 이미 등록된 특허를 회피하고, 동시에 기존 BBPFC 회로가 가지는 단점인 플로팅 게이트 드라이버를 활용하는 단점을 개선하는 새로운 형태의 브리지리스 PFC 컨버터를 제안한다. 제안된 컨버터는 기존 BBPFC가 가지는 장점인 좋은 (CM) 노이즈 특성을 가지며, 동시에 높은 효율을 달성 할 수 있다. 또한 제안된 컨버터의 경우, 복잡한 플로팅 형태의 게이트 드라이버 회로가 아닌 간단한 부트스트랩 회로를 활용하여 회로를 운용할 수 있다. 더불어 제안된 컨버터는 입력의 양과 음의 주기에서 단 하나의 스위치를 사용하여 회로를 구동할 수 있기 때문에 기존회로 대비 적은 손실을 가져 높은 효율의 획득이 가능하다. 본 논문에서는 제안된 구조에 대해 하이라인 $230V_{RMS}$ 입력과 800W / 400V 출력의 조건을 적용하여 제안하는 구조의 효용성을 검증하고자 한다.

  • PDF

A Study on the Characteristic Analysis of Hybrid Choke Coil suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Kim, Jong-Hae;Kim, Hee-Sung;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.32-43
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method, section bobbin and coil structure for hybrid choke coil capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke coil capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke coil, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke coil tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In case of hybrid choke coil using rectangular copper wire, it has investigated its parasitic capacitance compared to CM choke coil of conventional toroidal type becomes small. Also it has confirmed through the experiment results that CE margin and RE margin in frequency bands 0.5MHz to 5MHz and 30MHz to 200MHz are respectively 10dB and 15dB greater than that of conventional type in case of one stage EMI filter structure adopting hybrid choke coil compared to two stage EMI Filter structure using two of each CM choke coil used in the lower and higher frequency bands or two of CM choke coil used in only the lower frequency bands. In the future, the hybrid choke coil and CM choke coil of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Laptop Adapter, Server Power Supply and so on.

Power-Line EMI Filter for Broad-Band (전원용 광대역, 고성능 EMI 필터 개발에 관한 연구)

  • Chung Yeong-Chul;Lee Kyung-Won;Yook Jong-Gwan;Park Han-Kyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.56-65
    • /
    • 2005
  • We proposed the Power-line EMI filter for vehicle-shelter which have attenuation performance of 100 dB from 10kHz to 1 GHz. The inductor and capacitor for EMI filter design was charactenzed using circuit simulator and then, we experimentally verified 100 dB attenuation for the conducted emission noise through power line. This results will be used for the application systems of protection weapons against EMI attacks as well as vehicle-shelter.

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Flow Velocity and Mass Measurement Sensor of Constant Temperature Type (정온도형 유속 및 유량 측정센서)

  • Park, Se-Kwang;Kim, Hyoung-Pyo
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.35-41
    • /
    • 1992
  • A constant temperature type of flow sensor using a solid state micromachining technology was developed for measuring the velocity of gas or liquid. It was designed to detect only the heat convection related to flow velocity. Other heat transfer terms and common mode interferences are canceled by differentiating both reference and exposed flow sensor. It employs the principle that the change of current through the sensing element can be used to measure the flow velocity. An experimental study of the behavior on this flow sensor was performed in a narrow tube(diameter : 8mm) for city water. The relation between power consumption of the flow sensor and square-root of flow velocity is almost linear in the low velocity range(0-200 cm/sec).

  • PDF

Characteristics and Treatment Outcomes of Patients with Malignant Transformation Arising from Mature Cystic Teratoma of the Ovary: Experience at a Single Institution

  • Oranratanaphan, Shina;Khemapech, Nipon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4693-4697
    • /
    • 2013
  • Background: Malignant transformation arising in mature cystic teratoma (MCT) is one of the most serious complications of MCT. Squamous cell carcinoma is the most common malignant change. Some clinical findings such as advanced age group and large tumor size are significant risk factors of malignant transformation. This study was conducted in order to evaluate characteristics, cell types, treatment and outcome of malignant transformation arising from dermoid cysts in our institution. Materials and Methods: A retrospective chart review was performed. General characteristics, operative data, procedure, operative finding and operative outcome were analyzed. Statistical assessment was performed with SPSS version 17.0, using mean, mode, median and percentage to describe those data. Results: During the 10 years period, 11 cases of malignant transformation from a total of 753 cases (1.46% incidence) of MCT were reviewed. Mean age of the patients was 41.2 years (SD 4.34, range 24-70). The most common presenting symptom was a palpable mass (8 cases; 72.7%). Primary surgical staging was performed in 4 patients (36.4%). Re-staging was conducted in the other 4. Complete cytoreduction was obtained in 45.5% (5 cases) and optimal surgical resection was obtained in 36.4% (4 cases). Mean tumor size was 14.1 cm. (SD 1.55, range 6-20). Squamous cell carcinoma was found in 36.4% (4 cases) and mucinous cancer in the other 4. More than half of them were stage Ia (54.5%, 6 cases). All patients whose stage more than Ia received chemotherapy (45.5%). Mean disease free survival was 5.53 years (1.32, 0.3-10). Conclusion: According to our study, the incidence of malignant transformation was consistent with previous studies. The common malignant transformation histologic types are both squamous and mucinous carcinoma which differed from previous reports. Early detection for early stage disease and optimal surgery are important for long term survival.