• Title/Summary/Keyword: Common Operation Unit

Search Result 65, Processing Time 0.03 seconds

Parallel Inverse Transform and Small-sized Inverse Quantization Architectures Design of H.264/AVC Decoder (H.264/AVC 복호기의 병렬 역변환 구조 및 저면적 역양자화 구조 설계)

  • Jung, Hong-Kyun;Cha, Ki-Jong;Park, Seung-Yong;Kim, Jin-Young;Ryoo, Kwang-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.444-447
    • /
    • 2011
  • In this paper, parallel IT(inverse transform) architecture and IQ(inverse quantization) architecture with common operation unit for the H.264/AVC decoder are proposed. By using common operation unit, the area cost and computational complexity of IQ are reduced. In order to take four execution cycles to perform IT, the proposed IT architecture has parallel architecture with one horizontal DCT unit and four vertical DCT units. Furthermore, the execution cycles of the proposed architecture is reduced to five cycles by applying two state pipeline architecture. The proposed architecture is implemented to a single chip by using Magnachip 0.18um CMOS technology. The gate count of the proposed architecture is 14.3k at clock frequency of 13MHz and the area of proposed IQ is reduced 39.6% compared with the previous one. The experimental result shows that execution cycle the proposed architecture is about 49.09% higher than that of the previous one.

  • PDF

A Study on the Response Characteristics of a High Speed Solenoid (고속 솔레노이드의 응답특성에 관한 연구)

  • Cho, Kyu-Hak
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.12 no.2
    • /
    • pp.142-151
    • /
    • 2000
  • The studies on the electronic control fuel injection system for a DI diesel engine have done for reducing the exhaust emission and improving fuel consumption. The electronic control fuel injection system is classified into a common rail system, a unit injector system and a high pressure injection system. The characteristics of these systems are largely depends on the operating characteristics of its solenoid that have high speed on-off operation. In order to improve these characteristics of fuel injection system, it is necessary to design the optimal shape of solenoid and select the input method of its power source. It was proposed HELENOID, COLENOID, DISOLE, and Multipole Solenoid in the studies of design for the optimal shape of solenoid. The studies on the energizing method, input method for power of solenoid were dealt with the conventional energizing method, the chopping method and the pre-energizing method. In order to find out the high response characteristics of solenoid, it is necessary to test the performance of optimally designed solenoid with a new energizing method. In this paper, the solenoid of multi-pole type with plat armature and its power control unit to control input current by the chopping method designed, and its response tests were performed according to its energizing conditions. As a result, the maximum input current for solenoid was controlled by the period of first stage exciting current and chopping duty ratio of control stage exciting current, and the fastest "on" time was able to get 0.46ms. The conditions of fastest "on" time was 0.3ms for first stage exciting current, 0.16ms for control exciting current and 75% for chopping duty ratio.

  • PDF

Factors Influencing on Pressure Ulcer Incidence among Older Patients with Hip Fracture in a Hospital (고관절 골절로 입원한 노인 환자의 욕창 발생 위험요인)

  • Lee, Sun Jin;Jeong, Jae Shim;Lim, Kyung-Choon;Park, Eun Young;Kim, Hye Youn
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.1
    • /
    • pp.54-61
    • /
    • 2019
  • Purpose: This study aimed to identify the incidence and risks for pressure ulcer among older patients with hip fracture. Methods: The subject were 215 older patients suffering from hip fracture who were admitted for surgical operation from January 1, 2012 to April 30, 2016 in a university-affiliated hospital. The incidence of pressure ulcer was collected retrospectively through medical record review and the risk factors were analyzed using Cox's proportional hazard model. Results: Out of the total, 32 patients (14.9%) developed pressure ulcer with the average occurrence period being 4.72 (${\pm}3.81$) days. Stage II pressure ulcer was the most common at 72.0%. Risk factors included ambulation status before injury (p= .039), spinal anesthesia (p= .029), and stay at intensive care unit after operation (p= .009). Conclusion: Despite pressure ulcer prevention efforts, the incidence remained relatively high. Considering the identified risk factors, more efforts is needed for early detection and prevention of pressure ulcers in such patients.

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Steam Generator Management Program (원전 증기발생기 관리프로그램)

  • Cho, Nam-Cheoul;Kim, Moo-Soo;Lee, Kwang-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.610-616
    • /
    • 2003
  • Recently, the common concern of nuclear power industry in the development of technology mitigating and preventing the aging of steam generator tubes prevails, because the trends of steam generator flaws at Uljin unit #1,2 and KSNP(Korea Standard Nuclear Power Plant) impose a burden on the operation of nuclear power plant. While the regulatory agency is demanding the establishment of the advanced general performance maintenance system, the steam generator management program adapting advanced technology is being developed which may comply with EPRI PWR SG Guidelines based on NEI 97-06 ‘ General Guidelines including all the maintenance aspects consist of the tube integrity assessment criteria, repair limit, allowable leakage level, water chemistry will be composed in order to obtain the approval of regulatory agency and be applied to Nuclear power plant early 2005. This presentation is to introduce maintenance state including SG tube degradation and main contents of advanced SG management program being developed, and futhermore update present and future plan, and estimate the alternation after the completion.

  • PDF

Information Structure of Relative Clauses in English: a Flexible and Computationally Tractable Model

  • Song, Sanghoun
    • Language and Information
    • /
    • v.18 no.2
    • /
    • pp.1-29
    • /
    • 2014
  • Relativization is one of the common syntactic operations to merge two different clauses into a single information unit. This operation plays a pivotal role to structuralize multiple clauses cohesively as well as serves to specify the property an individual has within the context. That implies that relativization contributes to information structure of multiclausal sentences. In this context, this paper delves into information structure of relative clauses in English with an eye toward creation of a computational model from a standpoint of machine translation. The current work employs Head-driven Phrase Structure Grammar (HPSG, Pollard and Sag (1994)) as a theory of grammar and Minimal Recursion Semantics (MRS, Copestake et al. (2005) as a meaning representation system. Building upon these formalisms, this paper addresses how information structure of relative clauses can be represented and constrained. The current work makes use of Individual CONStraints (ICONS) for modeling relative clauses with respect to information structure. The current work also investigates which relative clause involves which information structure constraint. The present study argues that non-restrictive relative clauses impose a more specific constraint on information structure than restrictive relative clauses.

  • PDF

Residual salt separation technique using centrifugal force for pyroprocessing

  • Kim, Sung-Wook;Lee, Jong Kwang;Ryu, Dongseok;Jeon, Min Ku;Hong, Sun-Seok;Heo, Dong Hyun;Choi, Eun-Young
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1184-1189
    • /
    • 2018
  • Pyroprocessing uses various molten salts during electrochemical unit processes. Reaction products after the electrochemical processes must contain a significant amount of residual salts to be separated. Vacuum distillation is a common method to separate the residual salts; however, its high operation temperature may cause side reactions. In this study, a simple rotation technique using centrifugal force was suggested to separate the residual salts from the reaction products at relatively low temperature compared to the distillation technique. When a reaction product container with porous wall rotates inside a vessel heated above the melting point of the residual salt, the residual salt in the liquid phase is separated through centrifugal force. It was shown that the $LiNO_3-Al_2O_3$ mixture can be separated by this technique to leave solid $Al_2O_3$ inside the container, with a separation efficiency of 99.4%.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Estimation of the Expected Socio-economic Benefits of the Largescale Comprehensive Agricultural Development Project and Jointcost Allocation -In the Case of Kumgang Project Area- (대단위 농업종합개발사업의 사회경제적 기대편익 추정과 결합비용의 배분 -금강지구를 중심으로-)

  • Lim, Jae Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.159-176
    • /
    • 1996
  • This study is aimed at reviewing the methods of joint cost allocation and allocating the joint cost of estuary dam with specially repect to Kumgang Large-scale Agricultural Comprehensive Development Project. Apart from the water resource development project propelled by Water Resource Development Corporation in connection with Law of Multipurpose Dam Development, the Largescale Comprehensive Agricultural Development Projects couldn't ins-titutionally be carried out cost allocation of common facilities, even though it were concerned with irrigation, municipal and industrical water supply, flood control, sightseeing and industrial zone development components. To decrease farmer's burden of the project costs and, operation and maintenance costs, the joint costs of common facilities like estuary dam included in agricultural development projects have to be allocated by suitable method as alternative cost-remaining benefit method and the analytical activity should be supported by revising the concerned laws as Rural Development and Promotion and, Rural Rearrangement conpatible with the law for multipurpose dam development. Kumgang Agricultural Comprehensive Development Project was selected as a case study for the estimation of socio-economic benefits by project components and joint cost allocation of the estuary dam. The main results of the study are as follows; Joint cost allocation and unit charges by components 1. The project area will be 25,554ha with total project cost of 624,860 million won including the estuary dam cost of 120,843 million won. The project costs were ex-pressed by 1994 constant price. 2. Total quantity of water was estimated 365 million tons which were consisted of 245 million tons for irrigation, 73 million tons for municipal water and 47 million tons for industrial water. 3. The rates of joint cost allocation were amounted to 34.2% for agriculture, 2.5% for sightseeing, 45.7% for transportation, 11.8% for M & I water supply and 5.8% for flood control respectively. 4. The unit financial charges by project components were estimated at 7.88 won per ton for irrigation, 16.11won for M & I water, 1,686won per vehicle one pass, 977won per Pyeong according to the capital recovery method. The financial charges using straitline method for depreciation were estimated at 7.88won per ton for irrigation, 9.12won per ton for M & I water, 624won per vehicle one pass for transportation and 331won per Pyeong for sightseeing area. 5. The unit economic charges by project components were estimated at 21.1 won per ton for irrigation, 15.2won for M & I water, 977won per vehicle one pass, 977won per Pyeong according to the capital recovery method. The economic charges using straitline method for depreciation were estimated at 11.72won per ton for irrigation, 8.61won per ton for M & I water, 331won per vehicle one pass for transportation. Policy recommendation 1. The unit operation and maintenance costs for irrigation water in the paddy field couldn't be imposed as the water resource cost untreated. 2. The dam costs including investment cost and O & M cost, as a joint cost, had to be allocated by each benefited components as transportation, M & I water supply, flood control, irrigation and drainage, and sightseeing. But the agricultural comprehensive project have been dealt as an irrigation project without any appraisal socio-economic benefits and any allocating the joint cost of estuary dam. 3. All the associated project benefits and costs must be evaluated based on accounting principle and rent recovery rate of the project costs and O & M costs should be regulated by the laws concerned. 4. The rural development and promotion law and rural rearrangement law have to be revised comprising joint cost allocation considering free rider problems. 5. The government subsidy for the agricultural base development project has to be covered all the project costs. In case of common facilities representing joint cost allocation problems, all the allocated casts for other purposes like transportation and M & I water supply etc. should be recovered for formation in investment fund for agricultural base development and to procure O & M costs for irrigation facilities.

  • PDF

Short-Term Outcomes of Laparoscopic Total Gastrectomy Performed by a Single Surgeon Experienced in Open Gastrectomy: Review of Initial Experience

  • Song, Jeong Ho;Choi, Yoon Young;An, Ji Yeong;Kim, Dong Wook;Hyung, Woo Jin;Noh, Sung Hoon
    • Journal of Gastric Cancer
    • /
    • v.15 no.3
    • /
    • pp.159-166
    • /
    • 2015
  • Purpose: Laparoscopic total gastrectomy (LTG) is more complicated than laparoscopic distal gastrectomy, especially during a surgeon's initial experience with the technique. In this study, we evaluated the short-term outcomes of and learning curve for LTG during the initial cases of a single surgeon compared with those of open total gastrectomy (OTG). Materials and Methods: Between 2009 and 2013, 134 OTG and 74 LTG procedures were performed by a single surgeon who was experienced with OTG but new to performing LTG. Clinical characteristics, operative parameters, and short-term postoperative outcomes were compared between groups. Results: Advanced gastric cancer and D2 lymph node dissection were more common in the OTG than LTG group. Although the operation time was significantly longer for LTG than for OTG ($175.7{\pm}43.1$ minutes vs. $217.5{\pm}63.4$ minutes), LTG seems to be slightly superior or similar to OTG in terms of postoperative recovery measures. The operation time moving average of 15 cases in the LTG group decreased gradually, and the curve flattened at 54 cases. The postoperative complication rate was similar for the two groups (11.9% vs. 13.5%). No anastomotic or stump leaks occurred. Conclusions: Although LTG is technically difficult and operation time is longer for surgeons experienced in open surgery, it can be performed safely, even during a surgeon's early experience with the technique. Considering the benefits of minimally invasive surgery, LTG is recommended for early gastric cancer.