• Title/Summary/Keyword: Common Electrode

Search Result 172, Processing Time 0.028 seconds

Electrode Life Test of Resistance Spot Welding on Mg Alloy Using Dome Type Electrode (돔형 전극을 사용한 마그네슘 합금 저항 점용접의 전극 수명 평가)

  • Choi, Dong-Soon;Hwang, In-Sung;Kim, Dong-Cheol;Kang, Moon-Jin
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.27-31
    • /
    • 2013
  • Magnesium alloy is used on parts of aircraft and electronic equipment because of the highest specific strength among the common metal materials. Recently, studies about appling magnesium alloy sheet to automotive bodies are on the increase rapidly. For application to automotive bodies, researches about characteristics of resistance spot welding of magnesium alloy sheet are essential. Magnesium alloy has low boiling point, so getting sound bead shape is difficult when appling varies welding processes. Resistance spot welding is also particular about setting optimum welding conditions because of spatter generation, pores and cracks occurrence in nugget. And life of electrodes is very short because of alloying with copper that main material of electrodes. This requires frequent dressing and replacement of electrodes and decrease in productivity of resistance spot welding on magnesium alloy. Therefore in this study, for effective analysis of changes in tensile shear load and nugget size during electrode life test, evaluate detail characteristics of resistance spot welding on magnesium alloy sheet using dome type electrode.

The Effect of Needle Electrode Electrical Stimulation Following Global Ischemia on the Suppression of Apoptosis in the Cerebellum (전뇌허혈 유발 후 침전극저주파자극 적용이 소뇌의 세포자멸사 억제에 미치는 영향)

  • Wang, Joong-San;Park, Joo-Hyun;Moon, Ok-Kon;Kim, Nyeon-Jun;Choi, Jung-Hyun;Kim, Ji-Sung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1949-1958
    • /
    • 2013
  • This study conducted observation of tissues using the immunohistochemistry methods in order to see the effect of Needle Electrode Electrical Stimulation(: NEES) on apoptosis in the SD rat cerebellum caused by global ischemia which came from common carotid artery occlusion. The comparison and analysis results of expression of factors related to apoptosis among the control group, the global ischemia group and the NEES group showed that NEES following global ischemia had a significant effect on the reduction of c-fos expression in the SD rat cerebellum, and didn't have a significant effect on the reduction of bax and caspase-3 expression. In conclusion, it is considered that NEES following global ischemia is partially effective in suppressing the expression of factors related to apoptosis.

An Analysis of Paresthesia Areas Evoked by Spinal Cord Stimulation in Relation to the Position of Electrode Tip (척수자극기 전극의 위치에 따른 자극 부위에 대한 분석)

  • Lee, Mi Geum;Lee, Hyo Min;Jo, Ji Yon;Choi, Yun Suk;Ku, Ui Kyoung;Lee, Chul Joong;Lee, Sang Chul;Kim, Yong Chul
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.146-151
    • /
    • 2006
  • Background: Spinal cord stimulation is a well-established method for the management of several types of chronic and intractable pain. This form of stimulation elicits a tingling sensation (paresthesia) in the corresponding dermatomes. The goal of this study was to establish a correlation between the spinal levels of the implanted epidural electrodes and the paresthesia elicited due to stimulation of the neural structures. Methods: Thirty five patients, who received trial spinal cord stimulation, were evaluated. After the insertion of the lead to the selected position, the areas of paresthesia evoked by stimulation were evaluated. Results: Seventy-one percent of cases showed paresthesia in the shoulder area when the tip of the electrode was located between the C2⁣-C4 levels. At the upper extremities, paresthesia was evoked in 86⁣-93% of cases, regardless of the location of the electrode tip within the cervical spinal segments. The most common tip placement of the leads eliciting hand stimulation was at the C5 level. The most common level of electrode tip placement eliciting paresthesia of the anterior and posterior thigh and the foot were at the T7-⁣T12, T10⁣-L1 and T11-⁣L1 vertebral segments, respectively. Conclusions: Detailed knowledge of the patterns of stimulation induced paresthesia in relation to the spine level of the implanted electrodes has allowed the more consistent and successful placement of epidural electrodes at the desired spine level.

Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode

  • Xu, Guang-Ri;Xu, Guifang;Xu, Ming-Lu;Zhang, Zhengqing;Tian, Yuan;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.415-419
    • /
    • 2012
  • Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range $2.0{\times}10^{-6}$ to $5.0{\times}10^{-4}$ M with the detection limit of $2.0{\times}10^{-6}$ M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Cl^-$, $HPO_4^{2-}$ and $H_2PO_4^- $. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.

A Novel Pixel Structure for High Transmission TFT-LCD

  • Shin, Kyoung-Ju;Song, Se-Young;Lee, Il-Pyung;Kim, Chang-Hoon;Jang, Chang-Soon;Chai, Chong-Chul;Souk, Jun-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.208-210
    • /
    • 2008
  • We have developed a LCD Panel that form storage capacitance for pixels between pixel electrode of bottom glass and common electrode of top glass. This method could make higher transmission and higher production yield than before by removing storage electrode line and capacitance on the bottom glass by simplifying bottom pixel structure.

  • PDF

Influence of ionic liquid additives on the conducting and interfacial properties of organic solvent-based electrolytes against an activated carbon electrode

  • Kim, Kyungmin;Jung, Yongju;Kim, Seok
    • Carbon letters
    • /
    • v.15 no.3
    • /
    • pp.187-191
    • /
    • 2014
  • This study reports on the influence of N-butyl-N-methylpyrrolidinium tetrafluoroborate ($PYR_{14}BF_4$) ionic liquid additive on the conducting and interfacial properties of organic solvent based electrolytes against a carbon electrode. We used the mixture of ethylene carbonate/dimethoxyethane (1:1) as an organic solvent electrolyte and tetraethylammonium tetrafluoroborate ($TEABF_4$) as a common salt. Using the $PYR_{14}BF$ ionic liquid as additive produced higher ionic conductivity in the electrolyte and lower interface resistance between carbon and electrolyte, resulting in improved capacitance. The chemical and electrochemical stability of the electrolyte was measured by ionic conductivity meter and linear sweep voltammetry. The electrochemical analysis between electrolyte and carbon electrode was examined by cyclic voltammetry and electrochemical impedance spectroscopy.

Detection of Toxic Heavy Metal, Co(II) Trace via Voltammetry with Semiconductor Microelectrodes

  • Ly, Suw Young;Lee, Chang Hyun;Koo, Jae Mo
    • Toxicological Research
    • /
    • v.33 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • The cobalt (Co(II)) ion is a main component of alloys and considered to be carcinogenic, especially due to the carcinogenic and toxicological effects in the aquatic environment. The toxic trace of the Co(II) detection was conducted using the infrared photodiode electrode (IPDE) using a working electrode, via the cyclic and square-wave anodic stripping voltammetry. The results indicated a sensitive oxidation peak current of Co(II) on the IPDE. Under the optimal conditions, the common-type glassy carbon, the metal platinum, the carbon paste, and the carbon fiber microelectrode were compared with the IPDE in the electrolyte using the standard Co(II). The IPDE was found to be far superior to the others.

Pixel design for Improving Transmittance in OCB LCD

  • Lee, K.C.;Sha, Y.A.;Su, P.J.;Hsieh, C.H.;Chang, K.H.;Hsiao, C.C.;Fuh, S.Y.;Cheng, W.Y.;Liao, Y.C.;Yang, J.C.;Lo, K-L;Lee, D.W.;Chang, Y.P.;Shiu, J.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.395-398
    • /
    • 2007
  • Two new cell structures for optical compensated bend were proposed. There are two groups of slit electrodes, which are driven by two different signals corresponding to the entire electrode as common electrode. The transmittance was enhanced without increasing the response time and light leakage. Compared with the traditional OCB mode, the increment of the transmittance of each kind is about 90% and 30%.

  • PDF

Development of a Low-Noise Amplifier System for Nerve Cuff Electrodes (커프 신경전극을 위한 저잡음 증폭기 시스템 개발)

  • Song, Kang-Il;Chu, Jun-Uk;Suh, Jun-Kyo Francis;Choi, Kui-Won;Yoo, Sun-K.;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • Cuff electrodes have a benefit for chronic electroneurogram(ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram(EMG) activity from the surrounding muscle, the thermal noise generated within the source resistance, and the electric noise generated primarily at the first stage of the amplifier. This paper proposes a new cuff electrode to reduce the interference of EMG signals. An additional middle electrode was placed at the center of cuff electrode. As a result, the proposed cuff electrode achieved a higher signal-to-interference ratio compared to the conventional tripolar cuff. The cuff electrode was then assembled together with closure, headstage, and hermetic case including electronic circuits. This paper also presents a lownoise amplifier system to improve signal-to-noise ratio. The circuit was designed based on the noise analysis to minimize the electronic noise. The result shows that the total noise of the amplifier was below $1{\mu}V_{rms}$ for a cuff impedance of $1\;k{\Omega}$ and the common-mode rejection ratio was 115 dB at 1 kHz. In the current study, the performance of nerve cuff electrode system was evaluated by monitoring afferent nerve signals under mechanical stimuli in a rat animal model.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.