• Title/Summary/Keyword: Commercial Test

Search Result 2,684, Processing Time 0.027 seconds

Proposal for Using Sine with Dwell for the Evaluation of ESC for Medium Commercial Vehicles (중형 상용차량 ESC 평가를 위한 Sine with Dwell Test 제안)

  • Kwon, Baeksoon;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.2
    • /
    • pp.32-38
    • /
    • 2015
  • A sine with dwell test is well known as a test scenario for evaluation of performance of electronic stability control(ESC) on passenger vehicles and heavy commercial vehicles. However, when it comes to ESC for medium commercial vehicles, the test scenario has not been established yet. In this paper, the sine with dwell test was modified considering characteristics of medium commercial vehicles. The three main modifications of the original test scenario are the steering angle level, steering frequency, and loading condition of the vehicle. These modifications are derived from simulation study for different medium commercial vehicles. From simulation study, it was shown that the ESC system for medium commercial vehicle is objectively evaluated by the proposed test scenario. A clear improvement on vehicle stability was seen in the results when ESC system was used.

An Enduranc Test for the Commercial Operation of the Korean EMU (표준전동차 실용화를 위한 내구도 시험)

  • 정종덕;김원경;한석윤;이관섭
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.376-383
    • /
    • 2001
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. As of October, test result is good without severe problems. After 100,000km of test operation, the EMU will be delivered to operation cooperation for th commercial operation.

  • PDF

A Study on the Skin and Eye Testing of para-phenylenediamine and commercial hairdyes containing paraphenylenediamine in animals (실험동물에 대한 para-phenylenediamino을 함유하는 염모제의 피부 및 눈에 대한 시험)

  • Kim, Jung-Jin;Lee, Sun-Woo;Yong, Km-Chan
    • YAKHAK HOEJI
    • /
    • v.38 no.5
    • /
    • pp.562-567
    • /
    • 1994
  • Now para-phenylenediamine(PPDA) is generally used as component of most hairdyes because it can be used more conveniently and effectively than the others. But PPDA become known to cause side effects such as skin sensitization, contact dermatitis and eye irritation. So this study was done to restudy the safety of hairdyes containing PPDA. The results of experiment were as follows. 1. As a result of primary skin irritation test and eye irritation test in white rabbits, the solution containing 5% PPDA(in saline) were classified as weak irritant but four kinds of commercial hairdyes containing PPDA were proved not to have any irritation. 2. As a result of skin sensitization test in guinea pig, four kinds of commercial hairdyes were classified as Calss I(week irritant) but three kinds of commercial hairdyes induced skin sensitization for guinea pig to 5% in test groups. These results indicate that the actual toxicity of commercial hairdyes(four kinds) is negligible. But based on the results of experiment, it is thought that there is possibility of some commercial hairdyes to induce skin sensititization.

  • PDF

Thermal environmental performance evaluation of 4kW power electronic cooling system for commercial vehicle (4kW급 상용차량용 전력전자 냉방장치의 열 환경 성능평가)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.290-291
    • /
    • 2017
  • This study deals with an evaluation method for testing the robustness of the 4 kW commercial power electronic cooling system to the thermal environment. The power electronic cooling system consists of a cascaded push-pull DC / DC converter, a three-phase DC / AC inverter, and an electric compressor. The system manufactured by the thermal environment evaluation test (heat distribution test, thermal impact test, high temperature operation test, temperature cycle test, low temperature operation test) for the commercial electric power cooling system for commercial vehicle proves that it is robust against thermal environment.

  • PDF

The Study on Field Test of the New Formulated and Commercial Diesel Engine Oils (제조 디젤엔진 오일과 상업용 디젤엔진 오일의 실차시험 연구)

  • 김영운;정근우;강석춘
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.51-59
    • /
    • 2001
  • A diesel engine oil formulated in KRICT and a commercial diesel engine oil (API CG-4) were tested by car and their Kinematic Viscosity, TAN, TBN, metal content, additive depletion, anti-wear property and IR analysis were analyzed. From the research, both of the tested oils had almost the same properties f3r the change of TAN and TBN, but the change of Kinematic Viscosity of formulated oil was slightly higher than that of commercial oil. The iron content in the commercial oil increased rapidly from 7000 km while that of the formulated oil was still low. These results were confirmed by the anti-wear test with a 4-ball wear test machine for the each samples. Also, for the commercial oil, the depletion factor of the Zn-DTP which was added as an anti-wear property did not change any more after 7000 km. But, that of the formulated oil changed continuously to 8000 km, which means that the ability to prevent wear of the sliding pairs exists for the formulated oil. From the analysis results of oil properties obtained by field test, it was found that the commercial oil could be used only within 7000 km, but the formulated oil could be used more than 8000 km without severe wear of the sliding parts in the diesel engine.

  • PDF

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler (자트로파 유(Crude Jatropha Oil)에 대한 보일러 직접 연소 특성)

  • Kang, Sae-Byul;Kim, Jong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2934-2939
    • /
    • 2008
  • We conducted a test of a direct burning of crude Jatropha oil (CJO) in a commercial boiler system. The fuel, crude Jatropha oil is not biodiesel which comes from transeterification process of bio oil, but it is pure plant oil. The higher heating value (HHV) of the CJO is 39.3 MJ/kg (9,380 kcal/kg) and is higher than that of a commercial heating oil, 37.9 MJ/kg. The kinematic viscosity of CJO is 36.2 mm2/s at $40^{\circ}C$ and 8.0 mm2/s at $100^{\circ}C$. The burner used in the test is a commercial burner for a commercial heatingoil and its capacity is 140 kW (120,000 kcal/h). We did a preliminary test whether the combustion is stable or not. The preliminary test was a kind of open air combustion test using the commercial burner with crude Jatropha oil. We found that the combustion can be stable if the crude Jatrophaoil temperature is higher than $90^{\circ}C$. We measured the flue gas concentration by using a gas analyzer. The NOx concentration is $80{\sim}100\;ppm$ and CO concentration is nearly 0 ppm at flue gas O2 concentration of 3.0 and 4.5%.

  • PDF

Antimicrobial efficacies of alkaline disinfectant solution and commercial disinfectants against Brucella ovis

  • Yoo, Jong-Hyun
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.347-351
    • /
    • 2009
  • Bruella spp. involves a considerable danger of public health and farm animal industry. In this study, we assessed the disinfection efficacy of alkaline disinfectant solution and three commercial farm disinfectants (quaternary ammonium compound, sodium dichloroisocyanurate, potassium monopersulphate/sodium dichloroisocyanurate) against Brucella ovis. A bactericidal efficacy test by broth dilution method was used to determine the lowest effective dilution of selected disinfectants following exposure to test bacteria for 30 minutes at $4^{\circ}C$. Disinfectants and test bacteria are diluted with distilled water (DW), hard water (HW) or organic matter suspension (OM) according to treatment condition. Three commercial disinfectant showed excellent antimicrobial activity (up to dilution of $\times200$ in OM treatment). Alkaline disinfectant solution demonstrated favorable bactericidal efficacy against B. abortus (at dilution of $\times20$ in OM treatment). Three commercial farm disinfectants possess excellent efficacy against B. ovis. Alkaline disinfectant solution has lower potency than commercial farm disinfectant but could help to limit the spread of brucellosis.

Analysis of Salmonella Species from Eggs Using Immunoliposomes and Comparison with a Commercial Test Kit (면역리포좀을 이용한 계란에서의 살모넬라 분석과 시판 간이키트와의 비교)

  • Shin, Weon-Sun;Kim, Yoon-Sook;Lee, Jun-Soo;Kim, Myung-Hee
    • Food Science of Animal Resources
    • /
    • v.29 no.4
    • /
    • pp.533-538
    • /
    • 2009
  • To suggest an improved diagnostic method for Salmonella spp., analyses were conducted with immunoliposomes and compared with the results from a commercial test kit. One sample out of 36 samples of eggshell was Salmonella-positive via immunoliposomes. In the case of the use of the commercial test kit, six samples out of 36 samples were Salmonellapositive. These Salmonella-positive samples were subjected to biochemical identification tests that confirmed that they were Salmonella-negative. As for the egg content samples, they were Salmonella-negative in both analyses with immunoliposomes and the commercial test kit. The Salmonella analysis with immunoliposomes reduced detection time, by 24 h compared to the commercial test kit. Bacteria, including Acinetobacter baumanni, Chryseomonas luteola, Enterobacter cloacae, Escherichia coli, Escherichia hermannii, Klebsiella pneumonia, Pantoea spp., and Pasteurella pneumotropica, were isolated from the eggshells. Other than Acinetobacter baumanni and Pasteurella pneumotropica most of the isolates were known to frequently appear during egg production processing.

Evaluation of Commercial Anion Exchange Membrane for the application to Water Electrolysis (수전해 시스템에 적용하기 위한 상용 음이온교환막의 특성평가)

  • Jun Ho, Park;Kwang Seop, Im;Sang Yong, Nam
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.496-513
    • /
    • 2022
  • In this study, we sought to verify the applicability of anion exchange membrane water electrolysis system using FAA-3-50, Neosepta-ASE, Sustainion grade T, and Fujifilm type 10, which are commercial anion exchange membranes. The morphology of the commercial membranes and the elements on the surface were analyzed using SEM/EDX to confirm the distribution of functional groups included in the commercial membranes. In addition, mechanical strength and decomposition temperature were measured using UTM and TGA to check whether the driving conditions of the water electrolyte were satisfied. The ion exchange capacity and ion conductivity were measured to understand the performance of anion exchange membranes, and the alkaline resistance of each commercial membrane was checked and durability test was performed because they were driven in an alkaline environment. Finally, a membrane-electrode assembly was manufactured and a water electrolysis single cell test was performed to confirm cell performance at 60℃, 70℃, and 80℃. The long-term cell test was measured 20 cycles at other temperatures to compare water electrolysis performance.

An evaluation on 100,000km endurance test for the Korean EMU (표준전동차 10만km 내구도 시험평가)

  • 정종덕;김원경;한석윤;이호용;안태기;한성호
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.336-343
    • /
    • 2002
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. But endurance test come to an end well without severe problem. Hereafter, Korean EMU will be applied the quality certification of railroad supplies as a testing vehicle and their components will be applied in a new line.

  • PDF