• Title/Summary/Keyword: Commercial CFD

Search Result 816, Processing Time 0.026 seconds

CFD ANALYSIS FOR A PULSATILE FLOW AROUND A BODY INSIDE A BIFURCATED TUBE (분지관 내 물체 주위 맥동류에 대한 CFD 해석)

  • Hwang, D.Y.;Yoo, S.S.;Lee, M.S.;Han, B.Y.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.183-190
    • /
    • 2009
  • The objective of this study is to get simulation data about pulsatile flow around an interior solid body inside a bifurcated tube. All the processes were based on CFD method, with a commercial FVM code, SC/Tetra ver. 6.0 for solving, and with CATIA R16 for generating geometries. The bifurcated tube models were drawn with the bifurcated angle of 45 degrees, considering Murray's law about the diameter ratio. With various locations of the object, the effects of flow on the drag were considered. For the pulsating flow condition, the velocity wave profile was given as the inlet boundary condition. To validate all the result, the simulation was compared with the existing data of the other papers first. Overall flow field of both data were similar, but there was some difference at a zero velocity. Therefore the next simulation was continued with the sine wave profiles where there is no negative flow, and then the data was compared with one of the pulmonary artery velocity where there is negative flow. The final process was to calculate flow variables such as the wall shear stress (WSS) and to compute the drag of the solid object.

  • PDF

Circular Motion Test Simulation of KVLCC1 Using CFD (CFD를 이용한 KVLCC1의 Circular Motion Test 시뮬레이션)

  • Shin, Hyun-Kyoung;Jung, Jae-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.377-387
    • /
    • 2010
  • In this study, the turbulent free surface around KVLCC1 employed in the circular motion test simulation is numerically calculated using a commercial CFD(Computational Fluid Dynamics) code, FLUENT. Also, hydrodynamic forces and yaw moments around a ship model are calculated during the steady turning. Numerical simulations of the turbulent flows with free surface around KVLCC1 have been carried out by use of RANS equation based on calculation of hydrodynamic forces and yaw moments exerted upon the ship hull. Wave elevation is simulated by using the VOF method. VOF method is known as one of the most effective numerical techniques handling two-fluid domains of different density simultaneously. Boundary layer thickness and wake field are changed various yaw velocities of ship model during the steady turning. The calculated hydrodynamic forces are compared with those obtained by model tests.

Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor (연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측)

  • Park J. H.;Chae H. T.;Park C.;Kim H. I.
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

CO concentration distribution in a tunnel model closed at left end side using CFD

  • Peng, Lu;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.282-290
    • /
    • 2013
  • A primary air pollutant as an indicator of air quality released from incomplete combustion is Carbon monoxide. A study of the distributions of CO concentration with no heat source in a tunnel model closed at left end side is simulated with a commercial CFD code. The tunnel model is used to investigate the CO concentration distributions at three Reynolds numbers of 990, 1970, and 3290. which are computed by the inlet velocities of 0.3, 0.6 and 1.0 m/s. The CFD predictive approaches can be useful for a better design to analyze the distributions of CO concentrations. In the case of the tunnel model closed at left end side alone, the concentration changes of x/H=-5 and -2.5 have the similar laminar characteristics like the case of the tunnel model closed at both end sides expecially at low values of Reynolds number. Irregular average CO concentration variations at Re=1790 are considered that the transition from laminar to turbulent flow occurs even in three different tunnel models.

BENCHMARK TESTS FOR CFD CODES FOR THE ANALYSIS OF WIND FIELD IN THE FOREST (산림 바람장 해석을 위한 전산유체역학 코드들의 벤치마크 검증)

  • Park, T.W.;Chang, S.M.;Lee, B.
    • Journal of computational fluids engineering
    • /
    • v.17 no.2
    • /
    • pp.11-20
    • /
    • 2012
  • In this paper, the authors test various open codes and commercial codes based on CFD technology on the wind field around the complex terrain, which is a very important transport physics in the event of forrest fire. To study the physical mechanism inside the transition from surface fire to crown fire, the wake flow behind a parallel array of trees is studied numerically to show the flow separation in the turbulent boundary layer. Two sites near to Kunsan National University are chosen for the measurement of real wind field, and obtained data are compared with those from various computational codes such as Wind-Ninja, NIST-FDS, ANSYS-CFX, and ANSYS-FlUENT, etc. Through this research, feasibility and accuracy of the present CFD codes are investigated quantitatively, compared with the measured data with AWS.

In-Flight and Numerical Drag Prediction of a Small Electric Aerial Vehicle (비행시험과 전산해석을 통한 소형무인기 항력 예측)

  • Jin, Won-Jin;Lee, Yung-Gyo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.51-56
    • /
    • 2015
  • This paper presents the procedure of drag prediction for EAV-1, based on a numerical analysis correlated to an in-flight test. EAV-1, developed by Korea Aerospace Research Institute, is a small-sized UAV to test a hydrogen-fuel cell power system. The long-endurance test flight of 4.5 hours provides numerous in-flight data. The thrust and drag of EAV-1 during the flight test are estimated based on the wind-tunnel test results for EAV-1's propeller performance. In addition, the CFD analysis using a commercial Navier-Stokes code is carried out for the full-scale EAV-1. The computational result suggests that the initial CFD analysis substantially under-predicts the in-flight drag in that the discrepancy is up to 27.6%. Therefore, additional investigation for more accurate drag prediction is performed; the effect of propeller slipstream is included in the CFD analysis through "fan disk" modelling. Also, the additional drag from airplane trim and load factor that actually exists during the flight test in a circular path is considered. These supplemental analyses for drag prediction turn out to be effective since the drag discrepancy reduces to 2.3%.

PERFORMANCE IMPROVEMENT OF A RANGE HOOD SIROCCO FAN BY CFD FLOW ANALYSIS (렌지후드의 성능개선을 위한 시로코 팬 주위의 유동해석)

  • Han, B.Y.;Park, J.W.;Lee, M.S.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.159-165
    • /
    • 2008
  • A sirocco fan is widely used for discharging pollutants of a kitchen space since it is able to generate a relatively high air flow rate considering its small size and makes less noise than a axial fan or a centrifugal fan. However, it has a problem because its efficiency is low, and power consumption is larger. Performance of a sirocco fan is influenced by various factors such as number of the fan blades, diameter of the fan, geometry of the fan, geometry of its housing, revolution frequency, static pressure condition, and etc. This research investigated the effect on the performance of geometry of the housing. For CFD analysis, we used a commercial code, SC/Tetra, and used a sliding mesh method to give the same condition as an actual state. Verification of the CFD results is done by comparison of experimental data and numerical one about the suction flow rate, and it is confirmed that two results are well consistent. After we changed the shape of housing according to Archimedes' screw, we observed that suction efficiency is improved by 10.7% maximum.

  • PDF

Prediction of Performance Change for the Intake system of Smart UAV With Freestream Wind Direction Using CFD Analysis (CFD를 이용한 풍향에 따른 스마트무인기 흡기구 성능 변화 예측)

  • Jung Y. W.;Jun Y. M.;Yang S. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.95-99
    • /
    • 2004
  • The developing Smart UAV in KARI supposes high speed flight as like a conventional plane, as well as vertical takeoff and landing as like a helicopter. Therefore, the air intake system should be designed to provide the sufficient air flow to the engine and the maximum possible total pressure recovery at the engine intake screen over a wide range of flight conditions. For this purpose, we designed the intake system using a pilot type intake model and plenum chamber In this paper, we designed the intake model and analyzed the performance of designed intake system using the general-purpose commercial CFD code, CFD-ACE+ For 3-D calculation, we generated mesh using the unstructured gird and used $\kappa-\epsilon$ turbulence model. The analysis results of the total pressure variation and the velocity distribution was illustrated in this paper. The pressure recovery and distortion coefficient at a plane coincident with the compressor inlet were calculated and streamline variation through the intake system was investigated at the worst condition as well as the standard flight condition.

  • PDF

Numerical Investigation on Capture of Sub-Micron particles in Electrostatic Precipitator without Corona Discharger (코로나 방전기가 없는 전기집진기의 미세입자 집진에 관한 수치해석)

  • Lee, Jin-Woon;Jang, Jae-Sung;Lee, Seong-Hyuk
    • Journal of ILASS-Korea
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2011
  • This article presents computational fluid dynamics (CFD) simulations of sub-micron particle movements and flow characteristics in laboratory-scale electrostatic precipitator (ESP) without corona discharge, and for simulation, it uses the commercial CFD program (CFD-ACE) including electrostatic theory and Lagrangian-based equation for sub-micron particle movement. For validation of CFD results, a simple cylindrical type of ESP is simulated and numerical prediction shows fairly good agreement with the analytical solution. In particular, the present study investigates the effect of particle diameter, inlet flow rate, and applied electric potential on particle collection efficiency and compares the numerical prediction with the experimental data, showing good agreement. It is found that the particle collection efficiency decreases with increasing inlet flow rate because the particle detention time becomes shorter, whereas it decreases with the increase in sub-micron particle diameter and with the decrease of applied electric voltage resulting from smaller terminal electrostatic velocity.

Effects of Trim on Resistance Performance of a Ship (선박의 트림 자세가 저항 성능에 미치는 영향)

  • Park, Dong Woo;Lee, Sang Bong;Chung, Sung Seob;Seo, Heung Won;Kwon, Jae-Woong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.2
    • /
    • pp.88-94
    • /
    • 2013
  • The primary objective of the current work is to obviously analyze regarding effects of trim conditions of a ship on resistance performance using model test and CFD. Model tests at a towing tank are conducted to investigate resistance for trim conditions at the given same displacement. Measured resistance shows small but distinct differences according to trim conditions. However, these differences are difficult to be clarified by measured physical quantities and wave pattern analysis from model tests. CFD is employed for the assessment of resistance performance according to trim conditions. The flow computation is conducted considering free surface and dynamic trim using a commercial CFD code (STAR-CCM+). The initiative of the present work is to systematically demonstrate pressure resistance acting on each region of divided finite zones of ship surface along the length and draught direction of surface when pressure distribution on the ship is interpreted. Also, a standard to assess the pressure resistance applied on the divided regions of a ship is established.