• 제목/요약/키워드: Comfortable Indoor Environment

Search Result 136, Processing Time 0.028 seconds

Design and Development of IoT-based Indoor Environment Management Platform (IoT 기반의 실내환경 관리 플랫폼 설계 및 개발)

  • Lee, Wan-Jik;Kim, Se-Jin;Yoon, Jun-Keun;Jeong, Ja-Woon;Heo, Seok-Yeol
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.654-661
    • /
    • 2021
  • Air pollution caused by industrial development has become a level that can seriously threaten human health. In general, indoor air pollution is considered to be lower than outdoors, but modern people live indoors most of the time, thus it is essential to keep the indoor air quality comfortable in order to take care of one's own health and improve the quality of life. Therefore, the development of an indoor environment management platform using Internet of Things and data processing technology, which is currently drawing attention, is considered a very meaningful study. In this paper, we designed an IoT-based management platform that can remotely monitor and control indoor environments. In addition, the functions of the IoT terminal, gateway, and data server constituting the platform were implemented using open source and open libraries, and all functional operations were also verified. In particular, the IoT terminal and the gateway in this paper exchange data using BLE communication, so they can operate with relatively low power and since the gateway uses the BLE Advertising mode, it has the advantage of automatically recognizing IoT terminals that have not been previously configured.

A Study on the Autumn LED Emotional Lighting Color through the comparative analysis of the Daylighting and LED Lighting Color (자연광과 LED조명색채 비교분석을 통한 가을빛 LED감성조명 색채 연구)

  • Yang, Jung-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.1-13
    • /
    • 2011
  • The purpose of this study is the realization of LED light environment closely resembling the Autumn daylight which people feel comfortable with. This research was conducted through an optical experiment and Emotional evaluation through human's eyes. Human beings are affected by the color of light, quality and light intensity. Unlike the past when human beings have worked mainly in daylight, the urbanites today spend most of the time in indoor spaces. Therefore, the artificial light is needed to strive toward a spectrum of daylight. This study is purposed to provide the pleasant light environment for human beings and build its database. This study course is expected to contribute to the new design methodology of the related fields under the development of the LED emotional lighting color.

A Study on the Indoor Noise Limits of Apartment Houses from the Road Traffic Noise (도로교통소음에 대한 공동주택 내부소음 기준설정에 관한 연구)

  • Lee, Ju-Yeob;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1084-1091
    • /
    • 2005
  • The indoor noise limit for road traffic noises is needed to secure comfortable acoustical quality in apartment houses. To achieve this goal, psycho-acoustic experiments were carried out with road traffic noise sources modulated by the transmission loss characteristics of the external windows. Finally, a correlation analysis between noise rating index and subjective responses, and an analysis of satisfactory percentage of the dose-response curves varied with respondents was conducted. As a result of this study, followings are suggested. (1) On correlation between dose level and psycho-acoustical response, the initial level of negative feeling is located on $40.1\~40.6\;L_{eq}$ dB(A), (2) On the degree of satisfaction to road traffic noise. near $35\;\%$ point being same dissatisfaction degree is to be assumed $40\~41$ dB(A) of indoor noise level presented into three vocabulary. It is suggested to be reasonable level of 40 dB(A) on the indoor noise limits for intruding road traffic noise. and it is appropriate to be the 5 dB level difference between grades. The results of this study may be used to evaluate the acoustic threshold level for road traffic noise or as a basis for specifying the desired acoustic environment of dwellings.

A Study of Indoor Air Monitoring IoT System Customized for Medical Institutions (의료기관 맞춤형 실내 공기 모니터링 IoT 시스템 연구)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1217-1222
    • /
    • 2020
  • Currently, studies on environmental pollution are being conducted in worldwide including Korea. Among them, various efforts are being made to prevent the health and environmental pollution of the people nationwide by keeping and managing the indoor air of various facilities used by many users. In particular, it is suggested that many people who visit medical institutions have diseases or illnesses and may have a significant impact on chronic diseases such as headache, depression, neuroticism, heart disease, and cancer related to indoor air pollution. Considering this situation, this paper is expected to provide comfortable and clean indoor environment to the inmate by providing central monitoring of air pollution and automatic call function of the person in charge through indoor air monitoring IoT system to be applied to medical institutions.

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

A Study on the Space Environment Improvement of Youth Cultural Center considering Environment Psychology and Behavior - Focus on the Independent Facilities of Seoul Area - (환경심리행태를 고려한 청소년문화의집 공간환경 개선방안에 관한 연구 - 서울 지역 단독형을 중심으로 -)

  • Shin, Mi-Seon;CHoi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.77-86
    • /
    • 2012
  • The 5-day schoolweek system at the present has increased spare time of the youth. The society should use this opportunity to lead the youth to grow as a responsible community member as offering them programs to fulfill their desires and potential abilities. The purpose of this study is to have the improvements to give the youth appropriate and comfortable space. As the scope of the study, I selected a total of 5 places as each rating (the best, good, moderate, insufficient) 4 places in the comprehensive assessment conducted by youth facilities association among the independent buildings located in Seoul and 1 place after the assessment. As the methods of the study, with regard to environmental psychology and behavior and Youth cultural center, I investigated them theoretically as literature survey method, organized and analyzed, put them together through facilities research analysis and the survey. The research results are as follows : First, a static individual space should be placed in well accessibility due to high affinity for the facilities. Second, a dynamic individual space needs the place and equipment for physically and mentally healthy leisure culture. Third, a dynamic group space needs to provide ensuring service hours, setting proper size of space, comfortable indoor environment considering the relationship between physical activity and others. Fourth, a static group space needs to vary the programs to develop potential abilities by a variety of experiences to maintain the correlation the layout adjacent to leader's office.

  • PDF

Evaluation of Thermal Comfort during Sleeping in Summer - Part II : About mean Skin Temperatures and Physiological Signals - (여름철 수면시 온열쾌적감 평가 -제 2보 : 평균 피부온도 및 생리신호에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This study was performed to evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of EEGs and MST under four thermals conditions. Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. Their age was from 20 to 22 years old. They were healthy, and had regular sleep with consistent bed and wakeup time. It was checked whether they had a good sleep before the night of experiment. Experiments were performed in an environmental chamber of $4.1\times4.9\times2.7m$ size. EEGs were obtained from C3-A2 and C4-Al electrode sites. Sleep stages were classified, then TST, SWS latency and SWS/TST were calculated for the evaluation for sleep efficiencies on thermal conditions. As results, it was concluded that indoor thermal environments of $24\~26^{\circ}C$ was the best for comfortable and deep sleep.

A Study of Thermal Comfort by Winter Temperature Humidity Change (겨울철 온도 및 습도변화에 따른 온열쾌적감에 관한 연구)

  • Kim, Se-Hwan;Lee, Sung;Kim, Dong-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.803-809
    • /
    • 2007
  • To those who spend most time within a room, comfortable indoor environment is a very critical element to job performance and health. The comfort technology, which is for enhancing comfort in human living, relates with various factors to ensure human activities efficient, comfortable, safe and satisfactory. Experiments were performed in environmental chamber. Experimental conditions were combinations from three temperatures of 18, 22 and 26C, and two relative humidity levels of 45 and 60%. Air-flow was controlled to 0.1m/s through the experiment. Four male and four female university students participated in the experiments. They had normal blood pressure and their body temperature was under $37^{\circ}C$. From the experiments for evaluating thermal sensation to the air-heating conditions, relationships among TSV, CSV, $SET^*$, PMV were analyzed. Results can be summarized as followings; Thermal neutrality $SET^*$ of man and female was $24.8^{\circ}C$. In air-heating condition, $SET^*$ values for thermal comfort zone were $23.0{\sim}26.5^{\circ}C$. These values were higher than the values from ASHRAE.

Smart Home Service System Considering Indoor and Outdoor Environment and User Behavior (실내외 환경과 사용자의 행동을 고려한 스마트 홈 서비스 시스템)

  • Kim, Jae-Jung;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.473-480
    • /
    • 2019
  • The smart home is a technology that can monitor and control by connecting everything to a communication network in various fields such as home appliances, energy consumers, and security devices. The Smart home is developing not only automatic control but also learning situation and user's taste and providing the result accordingly. This paper proposes a model that can provide a comfortable indoor environment control service for the user's characteristics by detecting the user's behavior as well as the automatic remote control service. The whole system consists of ESP 8266 with sensor and Wi-Fi, Firebase as a real-time database, and a smartphone application. This model is divided into functions such as learning mode when the home appliance is operated, learning control through learning results, and automatic ventilation using indoor and outdoor sensor values. The study used moving averages for temperature and humidity in the control of home appliances such as air conditioners, humidifiers and air purifiers. This system can provide higher quality service by analyzing and predicting user's characteristics through various machine learning and deep learning.

A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area (충남지역 미적용 다중이용시설의 실내공기질에 관한 연구)

  • Hong, Sung-Chul;Jou, Hye-Mee;Cho, Tae-Jin;Lee, Che-Won;Jung, Yong-Taek;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.35-45
    • /
    • 2008
  • In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants ($PM_{10},\;CO_2$, CO, HCHO, TBC, $NO_2$, Rn, VOCs, asbestos, $O_3$) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as $PM_{10},\;CO_2$, CO, HCHO, TBC, Rn and $O_3$ were less than the recommended limits. However, the average concentration of VOCs was $521.73{\mu}g/m^3$ (GM : $221.69{\mu}g/m^3$), which was higher than the recommended limit of $400{\mu}g/m^3$. Moreover, the average concentration of $NO_2$ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to $CO_2$, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and $O_3$ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for $PM_{10}$, VOCs and $NO_2$. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were $44.75{\mu}g/m^3,\;555.07{\mu}g/m^3$ and $337.79CFU/m^3$, respectively. These concentrations were $120{\mu}g/m^3$ and $211.84CFU/m^3$ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and $O_3,\;PM_{10}$ and $NO_2$, HCHO and VOCs, $CO_2$ and Rn had positive relationships. However temperature and Rn, humidity and $CO_2,\;CO_2$ and $O_3,\;O_3$ and Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.