• Title/Summary/Keyword: Comfort Standard

Search Result 191, Processing Time 0.03 seconds

A Field Survey of Thermal Comfort in Office Building with Thermal Environment Standard (온열환경기준에 따른 여름철 사무실의 열쾌적성 평가)

  • Kong, Hyo-Joo;Yun, Geun-Young;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.37-42
    • /
    • 2011
  • This study aims to analyze the field survey of thermal comfort in office building with national thermal environment standard. Internal and external temperatures were measured at ten minute intervals and compared in accordance with the national standard for thermal environment. Sixty two workers filled in the questionnaire survey forms five times a day for 40 days. Field monitoring of offices in Seoul, Korea were conducted from 20 July to 28 August. Result for the comfort temperature was set a $26.30^{\circ}C$. This indicates that the 26 degree is reliable for the Korean standard. Indoor temperature standard can reduce energy use by air-conditioned buildings and the temperature would be offer comfort to occupants.

Correlation between the subjective comfort and elastic body pressure distribution on a bicycle saddel (자전거 안장의 연체압 분포와 주관적 안락도의 상관성에 관한 연구)

  • 최정윤;박경수
    • Proceedings of the ESK Conference
    • /
    • 1993.04a
    • /
    • pp.145-145
    • /
    • 1993
  • In bicycle design, saddle is the major part which effects the subjective comfort of rider. This study examines the correlation between the subjective comfort and elastic body pressure. The elastic body pressure measuring instrument for free-form surface such as saddle is developed by force sensor register, A/D converter and computer. The subjective comfort is measured quantit- atively by 11-point scale method and the elastic body pressure distribution is obtained through 3 different saddles at 4 postures. The pressure distribution is presented by computerized equi- pressure contour. While mean pressure, standard deviation of pressure, maximum pressure are inversely proportional to subjective comfort, the modified saddle-bearing weight which is the surface integral of pressure is directly proportional. Consequently, standard deviation of pressure is most important characteristic which affects variation of subjective comfort.

  • PDF

Impact of standard construction specification on thermal comfort in UK dwellings

  • Amoako-Attah, Joseph;B-Jahromi, Ali
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.253-281
    • /
    • 2014
  • The quest for enhanced thermal comfort for dwellings encompasses the holistic utilization of improved building fabric, impact of weather variation and amongst passive cooling design consideration the provision of appropriate ventilation and shading strategy. Whilst thermal comfort is prime to dwellings considerations, limited research has been done in this area with the attention focused mostly on non-dwellings. This paper examines the current and future thermal comfort implications of four different standard construction specifications which show a progressive increase in thermal mass and airtightness and is underpinned by the newly developed CIBSE adaptive thermal comfort method for assessing the risk of overheating in naturally ventilated dwellings. Interactive investigation on the impact of building fabric variation, natural ventilation scenarios, external shading and varying occupants' characteristics to analyse dwellings thermal comfort based on non-heating season of current and future weather patterns of London and Birmingham is conducted. The overheating analysis focus on the whole building and individual zones. The findings from the thermal analysis simulation are illustrated graphically coupled with statistical analysis of data collected from the simulation. The results indicate that, judicious integrated approach of improved design options could substantially reduce the operating temperatures in dwellings and enhance thermal comfort.

Evaluation for the Running Safety and Ride Comfort of Steel Composite Railway Bridge (강합성 철도교량의 주행안전성 및 승차감 평가)

  • Kim, Jung-Hun;Kang, Young-Jong;Kim, Dea-Hyeok;Han, Sang-Yun;Cha, Kyung-Ryul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2814-2820
    • /
    • 2011
  • Railway bridge, contact of vehicle needs to design considering the running safety about the running train load of the railway bridge, ride comfort and dynamic safety. Also, upper structure of the railway bridge has to satisfy design standard about moving load(train). So, the railway bridge has to satisfy the requirement for vertical acceleration of the bridge deck, vertical displacement of the bridge and face distortion, which is suggested railway design standard in Korea(2011.5.). In this study, it was investigated and evaluated to the running safety about the running train load of the railway bridge, ride comfort and dynamic safety with railway design standard for steel composite(Steel Box Girder) railway bridge considering KTX, freight train and standard train load.

  • PDF

Passenger Comfort Element Relationship from High-Speed Railway Car Safety Standard Side (고속철도차량 안전기준 측면에서의 승객 쾌적성 요소 관계)

  • Lee, Chan-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.62-65
    • /
    • 2006
  • From the research which it sees it tried to observe from the comfort viewpoint where the passenger feels the high-speed railway car safety standard which it is see clearly from the domestic railroad safety law. It presents a minimum safety standard, the passengers being an safety most, the place where to sleep receive the service which is comfortable from the railroad safety law and they do there is a most big difference. It analyzed the correlation of the comfort where the passenger feels the vehicle efficiency standard which it is presenting from railroad safety law 59th clause and from the research which it sees consequently.

  • PDF

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • v.25 no.4
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

Evaluations of Ride Comfort for the Rubber-Tired Light Rail Vehicle (고무차륜 경량전철 차량의 승차감 평가)

  • Kim Y.S.;Baek N.U.;Lim T.K.;Han S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.365-368
    • /
    • 2005
  • The dynamic model was developed to analyze vibration acceleration and ride comfort during the operation of rubber-tired light rail vehicles. The ride comfort for standing passengers was analyzed in accordance with ISO 2631-1, UIC 513R, and CEN Draft prENV 12299 using this model. The result was applied to the detail design of Korean-standard, rubber-tired light rail vehicles, and the detail specifications related to ride comfort was determined based on this result. The ride comfort test was performed along the test track by using 2 car-train, and its result was compared with that of the ride comfort analysis, verifying the validity of the developed dynamic model. It was also verified whether or not the developed Korean-standardized, rubber-tired light rail vehicle met specified target specifications on ride comfort.

  • PDF

A study on the ride comfort of high speed train in Korea (국내 고속철도 차량의 승차감에 대한 고찰)

  • 김영국;박찬경;김석원;김기환;이태형
    • Proceedings of the KSR Conference
    • /
    • 2003.10a
    • /
    • pp.131-137
    • /
    • 2003
  • In this paper, we introduce the characteristics of ride comfort for KTX(Korea Train express) and HSR 350(Korea High Speed Train project). The concept of term "ride comfort" is equivocal. Generally it is defined as the vehicle vibration. There are many studies on evaluation method of ride comfort for railway. In the case of KTX, the ride comfort has been evaluated according to ISO 2631 standard. But the ride comfort for HSR 350 has been assessed by UIC 513R. We have reviewed the ride comfort for KTX and HSR 350 by same method, such as ISO 2631 and UIC 513R, and compared the result of KTX with that of HSR 350.

  • PDF

A study on characteristics of thermal comfort for artificial environmental experiment in winter (동계 인공환경실험에 의한 온열쾌적특성 연구)

  • 박종일;김경훈;정성일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF