• Title/Summary/Keyword: Combustion residue

Search Result 36, Processing Time 0.023 seconds

Parkinson's Disease among Firefighters : A Focused Review on the Potential Effects of Exposure to Toxic Chemicals at the Fire Scene (리뷰 : 화재현장에서 노출될 수 있는 화학적 유해물질과 파킨슨병 간의 관련성)

  • Ye, Shinhee;Kim, Hyunjoo;Jeong-Choi, Kyunghee;Kim, Jieun E.;Park, Shinwon;Lee, Yumin;Ha, Eun-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.24 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • Previous studies have found that firefighters have a tenfold higher prevalence of Parkinson's disease (PD) compare to the general population. Firefighters are constantly exposed to various occupational hazards including toxic chemicals of fire residue and the toxic chemicals can effects development and progression of PD. Nevertheless, there were no studies about the association between exposure to chemical byproducts of combustion and the development of PD among firefighters. Thus the aim of this study is to look into existing researches regarding the effect of chemical byproducts of combustion on the development of PD. An extensive literature search was conducted to identify harmful chemical components of smoke and fire residue, using the PubMed database during November of 2016. We searched for relevant articles by combining several keywords that contained "Parkinson's disease" and each of the different toxic chemicals, yielding a total of 1401 articles. After applying the selection criteria, 12 articles were chosen. Chemical substances reported to have a harmful effect on PD, in at least one article, were carbon monoxide, toluene, manganese and lead. Carbon monoxide and metal substances including manganese and lead were found to be associated with an increased PD risk in more than two articles. There was a heightened risk of PD in firefighters due to exposure of chemical byproducts of combustion including carbon monoxide, toluene, manganese and lead. However, to the best of our knowledge, to support this result we need more systematic epidemiological studies about these risk factors of PD among firefighters. In addition, further studies for the effects of prolonged exposure to toxic fire residue on the development and progression of PD in firefighters are needed.

A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests (화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구)

  • Choi, Seung-Bok;Lee, Seung-Hun;Choi, Min-Ki;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.89-96
    • /
    • 2013
  • The purpose of this study is to check the fire origin and cause of the fire by observing the shape of the flame propagation in air-conditioner indoor unit through the fire tests. We supposed that the flame is spread from the surroundings to the top of the air-conditioner and ignited on top of the air-conditioner with n-heptane. And then repeated this experiment twice under the same conditions. After the ignition, refrigerant filled in air-conditioner and lubricating oil exploded with large explosion and flame having high temperature and pressure belched out rapidly due to bursting refrigerant pipe linked air-conditioner between 734 seconds and 559 seconds. After result of checking the combustion residue we found that almost all of that was lost except a part of the evaporator, motor and metal. The position of short-circuit traces of wiring for the air-conditioner ignited itself is similar to that of fire damage by external flame. Therefore, we verified that it is not certain to determine the ignition cause and point by only the shape of the combustion residues.

Conversion of organic residue from solid-state anaerobic digestion of livestock waste to produce the solid fuel through hydrothermal carbonization

  • Yang, Seung Kyu;Kim, Daegi;Han, Seong Kuk;Kim, Ho;Park, Seyong
    • Environmental Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.456-461
    • /
    • 2018
  • The solid-state anaerobic digestion (SS-AD) has promoted the development and application for biogas production from biomass which operate a high solid content feedstock, as higher than 15% of total solids. However, the digested byproduct of SS-AD can be used as a fertilizer or as solid fuel, but it has serious problems: high moisture content and poor dewaterability. The organic residue from SS-AD has to be improved to address these problems and to make it a useful alternative energy source. Hydrothermal carbonization was investigated for conversion of the organic residue from the SS-AD of livestock waste to solid fuels. The effects of hydrothermal carbonization were evaluated by varying the reaction temperatures within the range of $180-240^{\circ}C$. Hydrothermal carbonization increased the calorific value through the reduction of the hydrogen and oxygen contents of the solid fuel, in addition to its drying performance. Therefore, after the hydrothermal carbonization, the H/C and O/C atomic ratios decreased through the chemical conversion. Thermogravimatric analysis provided the changed combustion characteristics due to the improvement of the fuel properties. As a result, the hydrothermal carbonization process can be said to be an advantageous technology in terms of improving the properties of organic waste as a solid-recovered fuel product.

A study on the Combustion Characteristics of Wall Paper (내장벽지의 연소특성에 관한 연구)

  • Oh, Kyu-Hyung;Choi, Yeon-Yi;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.90-97
    • /
    • 2007
  • Combustion characteristics and toxicity of combustion gas of wallpaper samples were analyzed to evaluate the fire risk of wallpaper furnished in living space. In this study ash residue ratio was measured with high temperature electric furnace, and thermal analysis was carried out with TGA. Combustion time and smoke concentration were measured with cone heater and combustion gas analyzer. Smoke density of samples was measured using smoke chamber of ASTM E 662. The experimental results were showed as followings. Pyrolysis of silk wallpaper started at lower temperature compared to the other samples. It means that the silk wallpaper can be ignited at low heat flux and will have more fire risk than the others. Ignition time by radiation heat flux of silk wallpaper is shorter compared to the other samples, so evacuation time must be reduced. In the case of vinyl coated silk wall paper, carbon mono oxide concentration is the highest and the toxicity and damage effect to consciousness was stronger compared to the other samples. Smoke density of silk wall paper and fire retardant mixed coated silk wall paper were very high due to vinyl coating.

Automatic categorization of chloride migration into concrete modified with CFBC ash

  • Marks, Maria;Jozwiak-Niedzwiedzka, Daria;Glinicki, Michal A.
    • Computers and Concrete
    • /
    • v.9 no.5
    • /
    • pp.375-387
    • /
    • 2012
  • The objective of this investigation was to develop rules for automatic categorization of concrete quality using selected artificial intelligence methods based on machine learning. The range of tested materials included concrete containing a new waste material - solid residue from coal combustion in fluidized bed boilers (CFBC fly ash) used as additive. The rapid chloride permeability test - Nordtest Method BUILD 492 method was used for determining chloride ions penetration in concrete. Performed experimental tests on obtained chloride migration provided data for learning and testing of rules discovered by machine learning techniques. It has been found that machine learning is a tool which can be applied to determine concrete durability. The rules generated by computer programs AQ21 and WEKA using J48 algorithm provided means for adequate categorization of plain concrete and concrete modified with CFBC fly ash as materials of good and acceptable resistance to chloride penetration.

Gas Turbine Combustion and NOx Characteristics of Coal and Heavy Residue Oil Gases (석탄 및 중잔사유 가스의 가스터빈 연소/NOx 배출 특성)

  • Lee, Chan;Seo, Je-Young
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.503-508
    • /
    • 2003
  • IGCC 가스터빈의 연료로는 주로 CO와 H$_2$ 가연성분이 대부분인 석탄과 중사유 가스를 사용하며, 발열량은 천연가스의 1/5~1/10정도이다[1]. 이러한 증발열량 가스연료는 기존의 천연가스나 석유를 연소연료로 사용한 발전시스템에 그대로 적용되어 사용하는데는 무리가 따른다. 이는 천연가스나 석유에 비해 중, 저발열량의 연소특성이 매우 다를 수 있기 때문이다.(중략)

  • PDF

The Study on the Combustion and Ash Deposition Characteristics of Ash Free Coal and Residue Coal in a Drop Tube Furnace (DTF를 이용한 무회분 석탄과 잔탄의 연소 및 회 점착 특성에 관한 연구)

  • Moon, Byeung Ho;Kim, Jin Ho;Sh, Lkhagvadorj;Kim, Gyu Bo;Jeon, Chung Hwan
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.89-96
    • /
    • 2015
  • Recently, much research has been put into finding the causes and solutions of slagging/fouling problems that occur at the end of the boiler. This slagging/fouling, caused by low-rank coal's ash, disturbs the thermal power and greatly reduces efficiency. In environmental aspects, such as NOx pollution, governments have been implementing restrictions on the quantity of emission gases that can be released into the atmosphere. To solve these problems, research on Ash Free Coal (AFC), which eliminates ash from low-rank coal, is in progress. AFC has advantages over similar high-rank coals because it increases the heating value of the low grade coal, reduces the contaminants that are emitted, and decreases slagging/fouling problems. In this study, using a DTF, the changes of NOx emissions, unburned carbon, and the characteristics of ash deposition were identified. KCH raw coal, AFC extracted from KCH, residue coal, Glencore, and Mixed Coal (Glencore 85wt% and residue coal 15wt%) were studied. Results showed that AFC had a significantly lower emission of NOx compared to that of the raw coal and residue coal. Also, the residue coal showed a higher reactivity compared to raw coal. And finally, In the case of the residue coal and mixed coal, they showed a lower ash deposition than that of low-rank coal.

Study on the Characteristics of Bio-mass according to Various Process of Torrefaction (반탄화 공정 변화에 따른 바이오매스 연료의 특성 연구)

  • Ohm, Tae-In;Chae, Jong-Seong;Kim, Jung-Ku;Choi, Soo-A;Oh, Sea-Cheon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.375-378
    • /
    • 2014
  • In this study, we carried out torrefaction experiment using PKS(Palm Kernel Shell), and Bagasse as a raw material of oversee of herbaceous biomass and using waste wood and logging residue as a raw material of domestic of woody biomass. And then, by analyzing the physical & chemical properties, we investigated the characteristics as a fuel. By using the result of thermo gravimetric analysis, the biomass residue was torrefied for 30 minutes at a temperature range of $250-350^{\circ}C$ in anaerobic condition. As a result, torrefied materials of moisture content are lower than raw, but of fixed carbon, calorific value and ash are higher than raw.

  • PDF

Influence of carbonized crop residue on soil carbon storage in red pepper field

  • Lee, Jae-Ho;Eom, Ji-Young;Jeong, Seok-hee;Hong, Seung-Bum;Park, Eun-Jin;Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • v.41 no.12
    • /
    • pp.336-344
    • /
    • 2017
  • Background: Because of climate change, interest in the development of carbon pools has increased. In agricultural ecosystems, which can be more intensively managed than forests, measures to control carbon dioxide ($CO_2$) emission and absorption levels can be applied relatively easily. However, crop residues may be released into the atmosphere by decomposition or combustion. If we can develop scientific management techniques that enable these residues to be stocked on farmland, then it would be possible to convert farmlands from carbon emission sources to carbon pools. We analyzed and investigated soil respiration (Rs) rate characteristics according to input of carbonized residue of red peppers (Capsicum annuum L.), a widely grown crop in Korea, as a technique for increasing farmland carbon stock. Results: Rs rate in the carbonized biomass (CB) section was $226.7mg\;CO_2\;m^{-2}h^{-1}$, which was 18.1% lower than the $276.9mg\;CO_2\;m^{-2}h^{-1}$ from the red pepper residue biomass (RB) section. The Rs rate of the control was $184.1mg\;CO_2\;m^{-2}h^{-1}$. In the following year, Rs in the CB section was $204.0mg\;CO_2\;m{-2}h^{-1}$, which was 38.2% lower than the $330.1mg\;CO_2\;m^{-2}h^{-1}$ from the RB section; the control emitted $198.6mg\;CO_2\;m^{-2}h^{-1}$. Correlation between Rs and soil temperature ((Ts) at a depth of 5 cm) was $R^2=0.51$ in the RB section, which was higher than the other experimental sections. A comparison of annual decomposition rates between RB and CB showed a large difference, 41.4 and 9.7%, respectively. The results showed that carbonization of red pepper residues reduced the rates of decomposition and Rs. Conclusions: The present study confirmed that the Rs rate can be reduced by carbonization of residue biomass and putting it in the soil and that the Rs rate and Ts (5 cm) were positively correlated. Based on the results, it was determined that approximately $1.2t\;C\;ha^{-1}$ were sequestered in the soil in the first year and $3.0t\;C\;ha^{-1}$ were stored the following year. Therefore, approximately $1.5t\;C\;ha^{-1}year^{-1}$ are expected to be stocked in the soil, making it possible to develop farmlands into carbon pools.

Characteristics of RDF Char Combustion in a Bubbling Fluidized Bed (기포 유동층 내에서 RDF 촤의 연소 특성)

  • Kang, Seong-Wan;Kwak, Yeon-Ho;Cheon, Kyoung-Ho;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.429-432
    • /
    • 2011
  • The feasibility of applications of the char obtained from a gasification process of municipal-waste refuse derived fuel (RDF) as an auxiliary fuel was evaluated by combustion experiments. The higher heating value of the RDF char was 3000~4000 kcal/kg and its chlorine content was below the standard requirement demonstrating its potential as an auxiliary fuel. In the combustion exhaust gas, the maximum $NO_x$ and $SO_2$ concentrations were 240 ppm and 223 ppm, respectively. If an aftertreatment is applied, it is possible to control their concentrations low enough to meet the air pollutant emission standard. The HCl concentration was relatively high indicating that a care should be taken for HCl emission from the combustion of RDF. Based on the temperature distribution within the reactor, the concentration change of $O_2$ and $CO_2$, and the amount and the loss on ignition of solid residue, it was inferred that the combustion reaction was the most reliable when the excess air ratio of 1.3 was used.