• Title/Summary/Keyword: Combustion emission

Search Result 1,508, Processing Time 0.032 seconds

Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps (기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험)

  • Park, C.W.;Jurng, J.;Nam, P.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

Analysis of Fast Injection Response Characteristics Between Solenoid and Piezo-Driven Injector (솔레노이드 및 피에조 인젝터의 고속분사 응답성 해석)

  • Jo, In-Su;Lee, Jung-Hyup;Lee, Jin-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.971-977
    • /
    • 2012
  • It is well known that the performance of a diesel injector is directly related to the power, emission, and fuel consumption of the diesel combustion engine. In this study, the injection response characteristics of CRDi injectors driven by a solenoid coil and a piezoceramic were investigated by using the AMESim simulation code. Some analytical parameters such as the fuel pressure and hole diameter were considered. From this study, it was shown that the piezo-driven injector had a faster response and had better control capability than the solenoid-driven injector. In addition, it was found that the piezo-driven injector can be utilized more effectively in a multiple injection scheme than a solenoid-driven injector.

Combustion and NOx Emission Characteristics of the Gas Turbine Combustor Burning Medium-Btu Gas as Alternative Fuel (중발열량 가스 대체 시 가스터빈 연소기의 연소 및 NOx 배출 특성)

  • Lee, Chan;Seo, Je-Young
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.320-327
    • /
    • 2003
  • A CFD (Computational fluid Dynamics) research is conducted for the investigation of the fuel alteration of MBTU (medium-Btu) gas in IGCC gas turbine combustor. The computational analysis method of the gas turbine combustor is constructed by incorporating MBTU gas reaction and fuel NOx models into commercial CFD code. With the use of the present analysis method, comparisons are made on the flow velocity, the chemical species and the temperature distributions, and on the flame shape and behavior of gas turbine combustor firing natural gas and MBTU gases (coal gas, heavy residue oil gas). Furthermore, the NOx formation characteristics and the turbine matching condition of the combustor are analyzed. Based on the computed analysis results, the present study provides the directions for the redesign and the design modification of IGCC gas turbine combustor firing MBTU gas as alternative fuel.

Application and verification analysis of the thermoelectric generation system for a coastal fishing vessel (열전발전 장치의 연안어선 활용에 관한 연구)

  • LEE, Donggil;YANG, Yongsu;KIM, Pyungkwan;KIM, Seonghun;KIM, Hyunyoung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.196-203
    • /
    • 2017
  • The renewable energy sources can be thought of one of the major measures to reduce greenhouse gas emissions in the industries. However, the utilization technology for those sources is approaching in the different matters. One of them, thermoelectric generation might be applicable to fishing industry. A various of internal combustion engines are used in a wide range of fisheries. After the ignition process, the heat passed out from the exhaust outlet. Recycling the heat could be not only an energy source but also reduction of green gas emission. Therefore, this study was designed to verify the feasibility of generation from wasted exhaust gas and analyze the performance. The designed experiment devices were connected with a data logger and an electric loader to quantify the currency and voltage. The devices were installed in a coastal fishing vessel for a gillnet fishery. During the whole fishing trips, the amount of generation was measured by engine rpm and the fishing operation procedures including vessel operations. At the maximum 1,500 rpm in the practical range, the generation amount was 113.6 W. The amount difference in relation to connection method was within 5 W: serial connection was 111.4 W and parallel connection was 115.8 W.

A Study on the Performance Improvement in a V8 Type Turbocharged Intercooler D.I. Diesel Engine (V8형 터보차져 인터쿨러 직접분사식 디젤기관의 성능개설에 관한 연구)

  • 석동현;윤준규;차경옥
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.118-127
    • /
    • 2004
  • The purpose of this study is experimentally to analyze that intake port swirl, injection system and turbocharger have an effect on the engine performance and the emission characteristics in a V8 type turbocharged intercooler D.I. diesel engine of the displacement 16.7ι, and to suggest the improvement of engine performance. Generally to enhance engine power, TCI diesel engine is put to practically use turbo-charged intercoler in order to increase boost efficiency which is cooled boost air. As results of considering the factors of the intake port of swirl ratio 2.25, compression ratio 17.5, re-entrant 8.5$^{\circ}$ combustion bowl, nozzle hole diameter ${\Phi}$0.33*3+${\Phi}$0.35*2, nozzle protrusion 3.18mm, injection timing BTDC 12$^{\circ}$CA and turbo charger (compressor 0.6A/R+46Trim, turbine 1.0A/R+57Trim) is the best in the full range of operating in the engine performance and the exhaust characteristics of NO$\_$x/ concentration. Therefore their factors are appropriated as intake system, injection and turbocharger system.

An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor (슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템)

  • Lee, Joon-Hwan;Lee, Seung-Hwan;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.128-134
    • /
    • 2008
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank can improve dynamic characteristics under such a sudden load change, and power quality, fuel consumption, and pollutants can be improved remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

A Study on the Characteristics of Fuel Consumption and Emissions of Diesel Vehicles Using Engine Coolant Flow Rate On/Off Control (엔진 냉각수 유량 단속에 의한 디젤 차량의 연비 및 배기가스 특성 연구)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2069-2074
    • /
    • 2013
  • The use of the electromagnetic clutch water pump for internal combustion engine vehicles saves fuel and leads to a reduction in emissions. The clutch water pump allows the engine cooling system to select the optimum operation condition by using coolant flow rate on/off control. This study investigated the characteristics of fuel consumption and emissions of the diesel engine cooling system using the clutch water pump. The electromagnetic clutch operation reduced by about 49% of engine warm up period at idle condition and controlled the optimum high coolant temperature at driving condition. Therefore, fuel consumption was enhanced by about 5%, and emissions such as HC, CO and $CO_2$ were also reduced to a certain degree even though NOx increased a little bit, compared to those of the conventional water pump under NEDC mode which represents the real driving pattern.

A Study on the RDF fuel mixing with household and organic wastes (생활(生活)쓰레기 및 유기성폐기물(有機性廢棄物) 혼합(混合)에 따른 RDF 연료화(燃料化)에 관한 연구(硏究))

  • Ha, Sang-An;You, Mi-Young;Kim, Dong-Kyun;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.20 no.5
    • /
    • pp.52-57
    • /
    • 2011
  • This study was conducted to examine the possibilities to utilize the mixture of domestic and organic wastes from B-city as a fuel. All types of mixing ratio for uncarried waste, sludge cake, and food waste were found 10 generate heating value with 6,000 kcal/kg, and in case of sludge cake the concentration of toxic substance produced was found to be decreased as air-fuel ratio and temperature were increased. It was noted that toxic gases such as CO, NOx, and SOx were observed below concentration of emission standard, and temperature inside the incinerator was stabilized at 2 of air-fuel ratio and 800$^{\circ}C$. It was observed that a heating value of 6000 kcal/kg generated using RDF(Refuse Derived Fuel) was appropriate to utilize a fuel if a complete combustion was attained.

An usefulness study on estimation and control method of EGR ratio using intake manifold pressure in an gasoline engine (가솔린엔진에서 흡기관 압력을 이용한 EGR율의 추정 및 제어 방법에 관한 유용성 연구)

  • Park, Hyeong-Seon;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.806-813
    • /
    • 2014
  • The EGR system being reburned the part of the exhaust gas through intake system indicates more favorable emission characteristics to reduce NOx in a gasoline engine, but the case of inappropriate exhaust gas quantity induced from engine is fallen engine power caused by unstable combustion. In this study, we examined a method to predict EGR ratio according to various engine operation condition based by intake manifold pressure and confirmed such a prediction data through an experimental method. And after having constituted feedback EGR control algorithm in a base with such a prediction data, we acquired qualitatively similar results by having compared data provided through an EGR feedback control experiment with the data which calculated quantity of residual gas for the engine operation condition. Therefore, the applied algorithm and the system for feedback EGR control showed feasibility applied to real electronic control EGR technology.

Drying Characteristics of a Radiative Industrial Dryer Adopting a Mat-Type Premixed Catalytic Burner (매트 형태의 예혼합 촉매 버너에 의한 복사 건조 특성)

  • Kim, Hyouck-Ju;Ahn, Joon;Song, Kwang-Sup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.735-742
    • /
    • 2011
  • A catalytic burner that utilizes the thermal energy from fossil fuels without the emission of nitrogen oxides ($NO_x$) has been developed. For this purpose, the newly developed burner has two features: firstly, it is in the shape of a flat mat so as to maximize its heating surface, and secondly, it adopts premixed combustion so that it can be used in a closed space. In the present study, the burner was used in a radiation-type industrial dryer. This dryer yields thermal energy in the form of thermal radiation in the infrared regime, which has been proved to be effective for drying organic substances under low-moisture conditions. Analysis of the experimental data has proved that the thermal efficiency of the dryer is better correlated to the moisture than to the dry rate