• Title/Summary/Keyword: Combustion Diagnostics

Search Result 49, Processing Time 0.027 seconds

Measurments of 2-D Image Soot Distribution in Late Combustion Stage Using Elastic Scattering, Laser-Induced Incandescence and Flame Luminosity (레이저 탄성산란법, 여기적열법, 자발광을 이용한 가시화 디젤엔진의 후기연소의 2차원 soot 분포 측정)

  • Noh, S.M.;Won, Y.H.;Park, J.G.;Choi, I.Y.;Chun, K.M.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.162-167
    • /
    • 2000
  • Soot formation and oxidation is closely related to the combustion phenomena inside a diesel engine. Laser-based diagnostics provide a means for improving our understanding of diesel combustion, because they have highly temporal and spatial ability. To understand the soot behavior we did preliminary study by taking flame luminosity photographs and 2-D imaging soot distribution using Laser Elastic Scattering(LIS) and Laser-Induced Incandescence(LII). From the data we found that soot concentration was high in the bowl and disappeared from the central region in the late combustion stage.

  • PDF

A Study on the Flame Monitoring System Development (화염감시 시스템 개발에 관한 연구)

  • 백운보;황이철;이승종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.60-66
    • /
    • 2004
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislations, require very careful combustion management. The flame diagnostics system has been developed specially to meet these requirements. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions.

Measurments of 2-D Image Soot Distribution for Different Piston-Shapes of a DI Diesel Engine Using Elastic Scattering, Laser-Induced Incandescence and Flame Luminosity (레이저 탄성산란법, 여기적열법, 자발광을 이용한 직분식 디젤엔진의 피스톤 형상에 따른 2차원 soot 분포 측정)

  • Noh, S.M.;Won, Y.H.;Park, J.G.;Choi, I.Y.;Chun, K.M.
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.183-193
    • /
    • 2000
  • Soot formation and oxidation is closely related to the combustion phenomena inside a diesel engine. Laser-based diagnostics provide a means for improving our understanding of diesel combustion, because they have highly temporal and spatial ability. To understand the soot behavior we did preliminary study by taking flame luminosity photographs and 2-D images of soot distribution using Laser Elastic Scattering(LIS) and Laser-Induced Incandescence(LII). From the data we found that soot concentration was high in the bowl and disappeared from the central region in the late combustion stage and that soot exists in the flame using luminosity, LIS and LII.

  • PDF

Diode-Laser Absorption Sensors for measurement of combustion Gas (연소배기 가스의 계측을 위한 다이오드 레이저 센서)

  • Shin, Myung-Chul;Kim, Se-Won;Kim, Dong-Hyuck
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.3
    • /
    • pp.26-35
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser, Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. The results showed that gas concentrations of $O_2$, CO, $CO_2$, NO are accurately measured within ${\pm}2%$ error. The application of WMS method increased the beam intensity 2-3 times higher than DA method. It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

Optical Diagnostics for Combustion Phenomena in a Gasoline Engine (가솔린엔진의 광응용 연소계측 기술)

  • 이기형;이창식
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1052-1062
    • /
    • 1993
  • 지금까지 엔진내의 연소현상에 관한 많은 문헌들이 보고되고 있으나, 주로 계측기술에 관한 전 반적인 소개 내용이 많으며, 실제 엔진에 대한 적용 현황과 적용시 발생하는 문제점 및 해결책 등에 대한 보고는 많지않은 실정이다. 이 글에서는 필자가 경험한 계측과 가시화 기술을 중심으 로 엔진내의 연소현상 해석에 적용되는 최근의 광응용 계측기술 및 개발 동향을 소개하고자 한다.

  • PDF

The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System (TDLAS 시스템을 이용한 유해 배기가스의 농도 계측)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Chun, Kwang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Combustion Characteristics of Model Gas Turbine Combustor -Radical Luminous Intensity and Local Equivalence Ratio Measurement- (모형 가스터빈 연소기의 연소특성 -라디칼 자발광강도와 국소당량비계측에 대하여-)

  • 최병륜;김태한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1064-1071
    • /
    • 1994
  • There are three active radicals which become to the scale of flame diagnostics at the flame front. They are OH, CH and $C_2$ radical. For this, optical measurement system which could monitor simultaneously the luminous waves of three radicals, was constructed. These were analyzed statistically into the cross correlation, coherence and phase. Through such an statistical treatment, combustion characteristics was investigated at the primary zone of gas turbine combustor. The local equivalence ratio was predicted with the ratio of luminuous intensity between CH and $C_2$ radical. This result was matched up to the equivalence ratio calculated from gas composition within 5% error. In general, equivalence ratio was said to be 1.0 at flame front, but it could be increased up to about 1.2 depending on the degree of swirl intensity in case of changing properly the air amount of primary zone.

Soot Concentration Measurement in Diesel Engine Using Laser Sheet Beam (레이저 시트빔을 이용한 디젤엔진의 Soot 농도 계측)

  • Lee, J.S.
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.23-29
    • /
    • 2000
  • Recently the laser sheet technique has been developed to improve our limited understanding of the in-cylinder diesel combustion. The technique is capable of high temporal and spatial resolution, so that it is proved to be an adequate combustion diagnostics to find out exhaust emission formation. The optical signals of LIS(Laser Induced Scattering) and LII(Laser Induced Incandescence) images show informations for soot concentration within the optically accessible diesel engine. The LIS and LII signal images of soot concentration provide new insight into where and when soot occurs in a diesel engine.

  • PDF