• 제목/요약/키워드: Combustible characteristics

검색결과 176건 처리시간 0.025초

적외선 열화상법 및 FE-SEM을 활용한 마그네슘 연소특성에 관한 실험적 연구 (Experimental Study on the Combustion Characteristics of Magnesium using Infrared Thermography and FE-SEM)

  • 이준식;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.927-934
    • /
    • 2020
  • Magnesium powder has been widely used in various industries because it is light weight and extremely high mechanical strength including aeronautics and chemicals. However, magnesium, as a combustible metal, poses serious safety issues such as fires and explosions if it is not managed properly. Especially, magnesium's max adiabatic flame temperature is 3,340℃ and it is impossible to extinguish it by using water, CO2 and Halonagents. The aim of this study is to identify the combustion characteristics of magnesium powder. We carried out a combustion experiment, using 1 kg of magnesium (purity > 99 %, particle < 150 ㎛). The features of the magnesium burning process were scrutinized using infrared thermal image analysis. Also, a field-emission scanning electron microscope (FE-SEM) were used employed to analyze particulate composites and properties. It concludes the significant tendency of magnesium fire and light, combustion carbide's particle characteristics. This study contributes to make better prevention and response manners to magnesium fires, as well as fire investigation measures.

유류화재의 감식기법의 실험적 특성에 관한 연구 (A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids)

  • 황태연;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.7-14
    • /
    • 2012
  • 본 연구에서는 화재현장에서 유류와 관련되어 실화나 방화의 매개체로 사용되어 화재가 발생했을 때 석유류의 정확한 분석기법을 개발하기 위하여 발화지점 주변의 온도분포, 연소되고 남은 물질의 흔적과 GC/MS 분석으로 물질의 종류를 확인하는 것을 가연성 고체와 비교해서 실험하였다. 연구결과 천장에 도달하는 온도는 휘발유와 시너는 점화되자마자 불꽃이 생성되어 천장의 온도가 매우 빠르게 상승하여 그곳에 물질이 있을 경우 2차 화재발생이 전개될 것으로 나타났다. 연소된 후에 바닥에는 가연성 고체와 유류가 상이한 특징적인 패턴을 형성하였다. 연소된 장판은 탄화수소계열이지만 가스검지관을 통해 반응을 확인한 결과 가연성 고체는 아무런 반응을 띠지 않았으나 유류는 즉시 반응을 하였고 그 연소물질을 7일이 경과된 후에 GC/MS로 분석한 결과 유류의 존재를 확인할 수 있었다. 화재조사가 복잡한 과정이지만 물질의 특성을 통한 세밀한 조사는 유류화재를 입증하는 데 중요하고 GC/MS분석기기를 통해 실체를 확인하는 과정이 요구된다.

A Study the Physicochemical Characteristics of Municipal Solid Wastes

  • Kim, Young-Sik
    • 한국환경보건학회지
    • /
    • 제29권4호
    • /
    • pp.35-41
    • /
    • 2003
  • The objective of this study was investigate the generation rates, composition, proportion and calorific values each of material in the municipal solid wastes as well as the effect of incineration residual leachate on the environment in Yangsan sanitary landfill site. The results were as follows ; The annual average generation rate of municipal solid wastes in Yang-san is approximately 2.0 kg/cㆍd. The weight percent of combustible matters is on average 78∼87% and the lower heating values of municipal solid wastes is measured to be more than 2,151 kcal/kg after removing the briquette component. The food waste was major source of solid wastes in Yang-san city as 35% and its variation by seasons was negligible. Combustible part was larger than incombustible part of the domestic solid wastes in spring and summer. It is recommended that municipal solid wastes be treated by multiple methods such as the sanitary landfill, resources and recovery, composting and incineration.

생활쓰레기의 이화학적 특성 및 연소 속도론적 연구 (Study on Physico-chemical Characteristics and Combustion Kinetics Solid Waste)

  • 이건주
    • 유기물자원화
    • /
    • 제15권1호
    • /
    • pp.134-142
    • /
    • 2007
  • 본 연구는 생활쓰레기의 물리 화학적 분석 및 발열량 등으로 그 특성을 알고 반응기를 이용한 열중량감량 분석을 함으로써 열처리 시설의 가장 효율적인 운영에 기초자료가 됨을 목적으로 한다. 측정 결과는 다음과 같다. 쓰레기의 삼성분 중 가연분이 약 61%로 다른 수분(약 32%) 회분(약 7%)보다 함유량이 높았고 쓰레기의 원소분서결과 종류에 관계없이 탄소와 수고(약 94%)의 존재량이 대부분이었다. 쓰레기의 발열량 분석 결과 고위발열량은 2897.883(Kcal/kg)의 값을 갖는 것으로 나타났다. TGA를 이용하여 도시 생활쓰레기의 종류별 열적 특성을 분석한 결과 온도가 증가함에 따라서 시로 중에 함유된 휘발분이 지속적으로 무게 감량이 일어났으며 특히 $300{\sim}500^{\circ}C$에서 열중감량이 활발히 진행되고 그 반응속도에 차이가 있음을 알 수 있었다.

  • PDF

티타늄 합금 폐기물의 연소 특성에 관한 실험적 연구 (Experimental study on the combustion characteristics of titanium alloy)

  • 이준식;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.105-110
    • /
    • 2019
  • Most titanium alloy waste with cutting oil was discarded without recycling process so that it can be caused by metal and oil fires. However, there is no fire management system and studies on the titanium or titanium alloy waste in spite of high fire risk. The purpose of this experimental study is to identify the fire risk of the titanium alloy waste with cutting oil. We collected the 120g waste which was made in the biomedical titanium alloy cutting process. The waste was burned and conducted thermal image analysis with infrared camera. The experimental results which illustrated the process, characteristics, and trends of fire are presented. Firstly, the cutting oil was burned and partially the titanium alloy waste was burned. The maximum temperature of the fire was more than $650^{\circ}C$ in some specific spots. These results means when a lot of titanium alloy waste with cutting oil was ignited, this fire could connect the titanium fire. In other words, the fire has a flammable liquid fire and combustible metal fire at the same time. The experimental study could be used fire prevention, response, and investigation of the titanium alloy waste.

소규모 주거 공간 실물화재실험을 통한 적재 가연물의 연소특성 분석 (An Analysis of Combustion Characteristics of Residential Facilities through Real Fire Tests in a Small Residential Space)

  • 양소연;문민호;원정훈
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.73-79
    • /
    • 2022
  • In this study, real fire tests were performed on representative combustibles of residential facilities to analyze the fire behavior and combustion characteristics in a small residential space. The considered combustibles were a sofa, a combination of a desk and a chair, and a combination of a mattress and an electric mat. A compartment space fire test was performed using the room corner test equipment prescribed in the KS F ISO 9705 specification. Three real fire tests were conducted by placing the combustible material inside a small compartment with insulation and finishing materials and by igniting the combustible material. Results showed that the peak heat release rate and peak smoke production rate occurred in the combination of the mattress and electric mat. Furthermore, from the result of the fire rate analysis, it was estimated that the fire risk of the mattress and electric mat combination was the highest, followed by the sofa and thedesk and chair combination.

유기성폐기물 고체연료화를 위한 연소 및 제조과정의 특성연구 (A Study on the Characteristics of Combustion and Manufacturing Process on Refuse-derived Fuel by Mixing Different Ratios with Organic and Combustible Wastes)

  • 하상안
    • 유기물자원화
    • /
    • 제17권1호
    • /
    • pp.27-38
    • /
    • 2009
  • 본 연구는 유기성폐기물인 음식물폐기물과 하수슬러지를 가연성폐기물을 혼재하여 연료로 사용하기 위해서 제조과정과 연소공정에서 발생되는 특성을 분석하였다. 연료화 재질의 특성은 연도분석기를 이용하여 배연가스 성분을 조사하였고, 발열량은 봄베식 열량계를 이용하여 분석하였다. 연료화 재료의 특성연구를 위하여 기초조사 수분함량(%), 가연성 폐기물 비율, 회분량, 중금속, 각 성분 원소분석, 발열량, 중량 혼재비율에 따라서 분석하였다. $RDF_{k-1}$의 연료는 건조하수슬러지, 음식물폐기물 및 가연성폐기물 혼재비율에 따라 제조하였고, $RDF_{k-2}$는 피트모스, 타르 및 하수슬러지 혼합비율에 의해서 제조하였다. 연소실험은 공기비 2와 연소온도 $850^{\circ}C$의 최적조건 상태에서 실험을 실행하였다. 연소실험장치에서 연소시간 5, 10, 15분의 간격으로 실험하였다. 연소장치로의 주입 연료량은 50g을 주입하여 실행하였다. $RDF_{k-1}$의 연료는 혼재비율에 따라서 발열량 실험결과 6,900에서 8,120 kcal/kg까지 분석되었고, $RDF_{k-2}$는 4,014에서 8,050 kcal/kg까지 나타났다. 연도실험에서 연소의 효율은 RDF의 발열량, 수분, 원소구성성분과 재질의 다양한 혼재비율에 큰 영향을 미치는 것으로 나타났다. 제조된 연료의 $RDF_{k-1}$ 연소실험에서 가연성 성분의 혼재비율이 높은 경우 발열량과 $C_xH_y$ 농도 및 회분량이 증가하였다. $RDF_{k-2}$ 경우는 tar의 혼재비율의 증가함에 따라 발열량은 증가하나 회분량, CO와 $C_xH_y$의 농도발생이 증가하는 것으로 나타났다.

Study on the Combustion Characteristics of Tulip Tree (Liriodendron tulipifera) for Use as Interior Building Materials

  • Min Ji KIM;Sang-Joon LEE;Sejong KIM;Myung Sun YANG;Dong Won SON;Chul-Ki KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.410-418
    • /
    • 2023
  • In this study, the combustion characteristics of the Tulip tree, which is the representative broad-leaved afforestation tree in Korea, were analyzed. The flame retardant performance of the Tulip tree was analyzed by analyzing combustion characteristics on a total of three test samples; flame retardant treated, both flame retardant and oil stain-treated, and untreated. Then the flame retardance grade was classified for each of them. According to the result, test samples showed the strongest flame retardance were in order of flame retardant treated (C), both flame retardant and oil stain-treated (B), and untreated (A). As a result of analyzing the total heat emission and maximum heat emission rates, which is the evaluation standard for interior materials of Korean domestic buildings, test samples with flame retardant treat or flame retardant and oil stain treat were qualified for the flame-retardant standard. Both flame retardant and oil stain-treated samples showed higher total heat release (THR) and heat release rate compared to flame retardant-treated samples as the oil causes combustion with oxygen. On the other hand, they didn't qualify the THR in Quasi-non-combustible standards. To determine the correlation between the physical and combustion characteristics of wood, the combustion characteristics of other diffuse porous wood species, with which the Tulip tree is affiliated were analyzed, and noticed that the characteristic correlates with the density and quantity of wood. The results of this study are expected to be used as basic information on the combustion characteristics of the Tulip tree.

T시 생활폐기물의 물리화학적 특성 및 소각재 용출특성 (Physico-Chemical Characteristics of Municipal Solid Waste Generated from T City and Leaching Characteristics of the Incineration Ash)

  • 박준석
    • 유기물자원화
    • /
    • 제18권2호
    • /
    • pp.84-92
    • /
    • 2010
  • 본 연구는 강원도 T시를 중심으로 생활폐기물의 물리화학적 특성을 조사하여 생활폐기물의 적정관리 방안 및 처리방법에 활용할 수 있는 기초자료를 제공하고 하고자 실시되었다. 조사결과 T 시의 겉보기밀도는 평균 $231kg/m^3$이었으며, 가연성분과 비가연성분은 각각 94.0%와 6.0%이었다. 가연성분 중 음식물류폐기물(32.3%)과 종이류(41.2%)는 최근의 타 지역에 비하여 여전히 높은 비율을 차지하고 있어 철저한 분리배출이 필요하였다. 삼성분 중수분, 가연분, 회분의 함량은 각각 41.3%, 50.5%, 그리고 8.2%이었으며, 원소조성 중 탄소, 수소, 산소, 질소, 황, 염소의 함량은 각각 51.4%, 6.3%, 26.7%, 1.1%, 0.2%, 0.5%를 나타내었다. 습윤저위발열량은 2,704 kcal/kg으로 춘천시의 2,764 kcal/kg와 유사하였으나 과거 구로구, 고양시의 1,467~1,584 kcal/kg 보다는 1,000 kcal/kg 이상 높았다. 또한 조제된 소각재의 용출시험 실시결과 모두 지정폐기물 판정 기준치를 크게 하회하여 큰 문제가 없는 것으로 나타났다.