• 제목/요약/키워드: Combined sample

검색결과 574건 처리시간 0.042초

A Literature Study on Usage of and Satisfaction Levels with Combined Treatment Including Oriental and Western Medicine

  • Lim, Jung-Hun;Lim, Sung-Min
    • 대한약침학회지
    • /
    • 제15권3호
    • /
    • pp.7-12
    • /
    • 2012
  • Objective: This study aimed to summarize and analyze the usage of and the satisfaction levels with combined treatment including Oriental and Western medicine. Methods: We searched studies on the usage of and the satisfaction levels with combined treatment including Oriental and Western medicine over the past 10 yrs (2001-2011) from 3 Korean databases (National Assembly Library, Research Information Service System, and National Discovery for Science Leaders). The reviewers also conducted a summarizing analysis by sampling the literature according to the type of study, study period, region, study subjects, sample size, type of sampling, research method, data analysis, study instruments, main results, etc. Results: When the main results of six studies on combined treatment usage and satisfaction levels were considered together, the most important decisive factor in determining the usage of combined treatment was the illness of the patient, followed by the patient's occupation, sex, age, education, marital status, religion, treatment cost, and treatment results. In addition, the most important factor that determined satisfaction levels with combined treatment was age, followed by education, religion, income, health status, treatment procedures, staff attitude, and cleanliness. Conclusions: Elderly patients with musculoskeletal, cerebro-vascular, and circulatory system illnesses are more likely to prefer combined treatment over independent Oriental or Western treatment and are more likely to request specialized, adjusted medical care.

Development of robust Calibration for Determination Sweetness of Fuji Apple fruit using Near Infrared Reflectance Spectroscopy

  • Sohn, Mi-Ryeong;Kwon, Young-Kill;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • 제2권1호
    • /
    • pp.55-58
    • /
    • 2001
  • The object of this work was to investigate the influence of growing district and harvest year on calibration for sweetness (Brix) determination of Fuji apple fruit using near infrared (NIR) reflectance spectroscopy, and to develop the robust calibration across these variation. The calibration models was based on wavelength range of 1100∼2500 nm using a stepwise multiple linear regression. A calibration model by sample set of one growing district was not transferable to other growing districts. The combined calibration (data of three growing districts) predicted reasonable well against a population set drawn from all growing districts (SEP=0.69, Bias=0.075). A calibration model by sample set of one harvest year was not also transferable to other harvest years. The combined calibration (data of three harvest years) predicted well against a population set drawn from all harvest years (SEP=0.53, Bias=0.004).

Reverse-bias Leakage Current Mechanisms in Cu/n-type Schottky Junction Using Oxygen Plasma Treatment

  • Kim, Hogyoung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.113-117
    • /
    • 2016
  • Temperature dependent reverse-bias current-voltage (I-V) characteristics in Cu Schottky contacts to oxygen plasma treated n-InP were investigated. For untreated sample, current transport mechanisms at low and high temperatures were explained by thermionic emission (TE) and TE combined with barrier lowering, respectively. For plasma treated sample, experimental I-V data were explained by TE or TE combined with barrier lowering models at low and high temperatures. However, the current transport was explained by a thermionic field emission (TFE) model at intermediate temperatures. From X-ray photoemission spectroscopy (XPS) measurements, phosphorus vacancies (VP) were suggested to be generated after oxygen plasma treatment. VP possibly involves defects contributing to the current transport at intermediate temperatures. Therefore, minimizing the generation of these defects after oxygen plasma treatment is required to reduce the reverse-bias leakage current.

Fumaric acid와 mild heat의 병합 처리에 따른 시금치의 저장 중 미생물 제어 효과 (Combined Treatment of Fumaric Acid with Mild Heat to Inactivate Microorganisms on Fresh Spinach during Storage)

  • 손현정;강지훈;오덕환;민세철;송경빈
    • Journal of Applied Biological Chemistry
    • /
    • 제59권1호
    • /
    • pp.69-74
    • /
    • 2016
  • 시금치에 fumaric acid와 mild heat의 병합처리를 통해 병원성 미생물 제어효과를 규명하고자 시금치에 E. coli O157:H7, L. monocytogenes 를 접종한 후 각 단일처리 후 미생물 수 변화를 측정하였다. Fumaric acid (0.1, 0.3, 0.5%)와 mild heat (40, 50, $60^{\circ}C$)의 각 단일처리 실험 결과를 토대로, 병합처리를 위한 fumaric acid의 최적농도는 0.5%, mild heat 처리조건으로 $50^{\circ}C$에서 5 min으로 선정하였고, 병합처리 시 L. monocytogenes, E. coli O157:H7의 수는 대조구에 비해 각각 2.53, 2.62 log CFU/g 감소하였다. 그리고 신선한 시금치에 병합처리 후 $4^{\circ}C$에서 12일간 저장하면서 미생물 수 감소 및 품질 변화를 조사하였다. 시금치의 초기 미생물 수에 있어서 대조구와 비교하여, 병합 처리구에서 총 호기성 균을 2.77 log CFU/g 감소시켰다. 특히, 저장 12일 후 병합 처리구의 총 호기성 균 수는 4.84 log CFU/g으로 대조구와 비교하여 1.82 log CFU/g의 감균 효과를 가졌다. 또한 시금치의 저장 중 Hunter 색도 값 및 비타민 C 함량에 있어서 처리구 간의 유의적인 차이를 보이지 않았다. 따라서 본 연구 결과, fumaric acid와 mild heat의 병합처리가 시금치의 미생물학적 안전성 유지에 효과적인 처리라고 판단된다.

Nonparametric Estimators of Ratio of Scale Parameters Based on Rank-Like Tests

  • Song, Moon-Sup;Chung, Han-Young
    • Journal of the Korean Statistical Society
    • /
    • 제9권2호
    • /
    • pp.181-193
    • /
    • 1980
  • A class of nonparametric estimators of the ratio of scale parameters is proposed. The estimators are based on the distribution-free rank-like test suggested by Fligner and Killeen (1976). An explicit form of the estimator is the median of the ratios of absolute deviations from the combined sample median. A small-sample Monte Carlo study shows that the proposed estimator is more efficient than the Bhattacharyya (1977) estimator. The proposed estimator is is reasonably insensitive to small failures in the assumption of equal medians. A modified estimator is also considered when the meidans are unequal.

  • PDF

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Bulk Amorphous and/or Nanocrystalline Finemet Alloy Prepared by Super-high-pressure Consolidation

  • Lu, Wei;Yanb, Biao
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.788-789
    • /
    • 2006
  • Microstructure and soft magnetic properties of bulk amorphous and/or nanocrystalline $Fe_{73.5}Cu_1Nb_3Si_{13.5}B_9$ alloys prepared by consolidation at 5.5GPa were investigated. The relative density of the bulk sample 1 (from amorphous powders) was 98.5% and the grain sizes were about 10.6nm. While the relative density and grain sizes of bulk sample 2 (from nanocrystalline powders) are 98% and 20.1nm, respectively. Particularly, the bulk samples exhibited a good combined magnetic property: for Sample1, $M_s=125emu/g$ and $H_c=1.5Oe;$ for Sample2, $M_s=129emu/g$ and $H_c=3.3Oe$. The success of synthesizing the nanocrystalline Fe-based bulk alloys will be encouraging for the future development of bulk nanocrystalline soft magnetic alloys.

  • PDF

담배 중 멘톨 분석에 대한 불확도 측정 (Uncertainty in Determination of Menthol from Mentholated Cigarette)

  • 장기철;이운철;백순옥;한상빈
    • 한국연초학회지
    • /
    • 제22권1호
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF

Face Recognition Robust to Occlusion via Dual Sparse Representation

  • Shin, Hyunhye;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.46-48
    • /
    • 2016
  • Purpose In face reocognition area, estimating occlusion in face images is on the rise. In this paper, we propose a new face recognition algorithm based on dual sparse representation to solve this problem. Method Each face image is partitioned into several pieces and sparse representation is implemented in each part. Then, some parts that have large sparse concentration index are combined and sparse representation is performed one more time. Each test sample is classified by using the final sparse coefficient where correlation between the test sample and training sample is applied. Results The recognition rate of the proposed algorithm is higher than that of the basic sparse representation classification. Conclusion The proposed method can be applied in real life which needs to identify someone exactly whether the person disguises his face or not.