• Title/Summary/Keyword: Combined interference

Search Result 199, Processing Time 0.027 seconds

An AFM-based Edge Profile Measuring Instrument for Diamond Cutting Tools

  • Asai, Takemi;Motoki, Takenori;Gao, Wei;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.54-58
    • /
    • 2007
  • This paper describes an atomic force microscope (AFM)-based instrument for measuring the nanoscale cutting edge profiles of diamond cutting tools. The instrument consists of a combined AFM unit and an optical sensor to align the AFM tip with the top of the diamond cutting tool edge over a submicron range. In the optical sensor, a aser beam is emitted from a laser diode along the Y-axis and focused to a small beam spot with a diameter of approximately $10{\mu}m$ at the beam waist, which is then received by a photodiode. The top of the tool edge is first brought into the center of the beam waist by adjusting it in the X-Z-plane while monitoring the variation in the photodiode output. The cutting tool is then withdrawn and its top edge position at the beam center is recorded. The AFM tip can also be positioned at the beam center in a similar manner to align it with the top of the cutting edge. To reduce electronic noise interference on the photodiode output and thereby enhance the alignment accuracy, a technique is applied that can modulate the photodiode output to an AC signal by driving the laser diode with a sinusoidal current. Alignment experiments and edge profile measurements of a diamond cutting tool were carried out to verify the performance of the proposed system.

End-fitting Design and Performance Evaluation of Polymer Insulator (폴리머 애자의 End-fitting 설계 및 성능 평가기술)

  • Cho, H.G.;Lee, U.Y.;Han, S.W.;Han, D.H.;Ji, W.Y.;Yeo, H.G.;Kang, D.W.;Chun, J.U.;Lee, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

Clinical Investigation of Surgical Spontaneous Pneumothorax (외과적 자연기흉의 임상적 고찰)

  • 윤윤호
    • Journal of Chest Surgery
    • /
    • v.1 no.1
    • /
    • pp.19-24
    • /
    • 1968
  • A clinical investigation was reported on 17 cases of spontaneous pneumothorax requiring surgical mana-gement. Males outnumbered females 15:2. Determination of the etiology in this series showed that the majority were pulmonary tuberculosis and paragonimiasis. Several others had pneumonia, lung abscess, cyst and blebs. It is of particular interest that the acute inflammation of respiratory system was younger age group, pulmonary tuberculosis & paragonimiasis were between 2 nd and 3 rd decades, and lung abscess, cyst, blebs were above 4 th decade. Pulmonary tuberculosis was far advanced bilateral and active. The ratio of right to left side was 13:6 and both side involved in 2 cases. In about half cases of patients, above 50%-collapsed lung associated with mediastinal shifting developed. The complications were pleural effusion and bronchopleural fistula. The former was 13 cases [76.4%] in which 3 cases combined with mixed infection, and latter was 5 cases. As the management, 11 cases were subjected to intercostal or rib resection drainage with continuous suc-tion. Among 11 drainage cases, 8 cases were successful in acute stage and 3 cases failed in chronic stage. This faiure was due to interference with re-expansion of collapsed lung for peel formation and broncho-pleural fistula. The open thoractomy was applied in 9 cases, among which primary operation were 5 cases and drainage failure were 4 cases. Among 11 cases subjected to the open thoracotomy, wedged resection was performed in 3 cases including paragonimiatic cyst, and pneumonectomy in 1 case-tuberculosis, and decortication only was performed in 2 cases in paragonimiasis. Decortication & lung resection was carried out in 2 patients among which ruptured lung abscess 1 case and ruptured multiple blebs 1 case. There was no case of death but prognosis of the tuberculosis may be poor because of far advanced bilateral and active pulmonary tuberculosis.

  • PDF

Evaluating Interfacial Adhesion Properties of Pt/Ti Thin-Film by Using Acousto-Optic Technique (Acousto-Optic 기법을 이용한 Pt/Ti 박막 계면의 접합특성 평가)

  • Park, Hae-Sung;Didie, David;Yoshida, Sanichiro;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.188-194
    • /
    • 2016
  • We propose an acousto-optic technique for the nondestructive evaluation of adhesion properties of a Pt/Ti thin-film interface. Since there are some problems encountered when using prevailing techniques to nondestructively evaluate the interfacial properties of micro/nano-scale thin-films, we applied an interferometer that combined the acoustic and optical methods. This technique is based on the Michelson interferometer but the resultant surface of the thin film specimen makes interference instead of the mirror when the interface is excited from the acoustic transducer at the driving frequency. The thin film shows resonance-like behavior at a certain frequency range, resulting in a low-contrast fringe pattern. Therefore, we represented quantitatively the change in fringe pattern as a frequency spectrum and discovered the possibility that the interfacial adhesion properties of a thin film can be evaluated using the newly proposed technique.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Design of Smart Farm Growth Information Management Model Based on Autonomous Sensors

  • Yoon-Su Jeong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.113-120
    • /
    • 2023
  • Smart farms are steadily increasing in research to minimize labor, energy, and quantity put into crops as IoT technology and artificial intelligence technology are combined. However, research on efficiently managing crop growth information in smart farms has been insufficient to date. In this paper, we propose a management technique that can efficiently monitor crop growth information by applying autonomous sensors to smart farms. The proposed technique focuses on collecting crop growth information through autonomous sensors and then recycling the growth information to crop cultivation. In particular, the proposed technique allocates crop growth information to one slot and then weights each crop to perform load balancing, minimizing interference between crop growth information. In addition, when processing crop growth information in four stages (sensing detection stage, sensing transmission stage, application processing stage, data management stage, etc.), the proposed technique computerizes important crop management points in real time, so an immediate warning system works outside of the management criteria. As a result of the performance evaluation, the accuracy of the autonomous sensor was improved by 22.9% on average compared to the existing technique, and the efficiency was improved by 16.4% on average compared to the existing technique.

INTRAOSSEOUS TOOTH MIGRATION OF IMPACTED MESIODENS IN THE INVERTED POSITION (상악 정중부에 역위 매복된 과잉치의 악골 내 이동)

  • Lee, Suk-Woo;Lee, Jae-Ho;Kim, Seong-Oh;Choi, Hyung-Jun;Sohn, Hyung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.750-756
    • /
    • 2008
  • Supernumerary teeth are frequently found in the anterior portion of the maxilla and develop as a result of abnormal proliferation of the dental lamina during tooth germ formation, caused by genetic or environmental factors. They may result in various complications, such as eruption interference, displacement, rotation of adjacent teeth, diastema, eruption into the nasal cavity, and development of dentigerous cyst. The optimal time for surgical extraction of supernumerary teeth has been a controversial issue. Someone prefer early surgical extraction because supernumerary teeth can cause eruption interference and displacement of adjacent teeth, eventually altering occlusion. Others prefer to delay surgical extraction until $8{\sim}10$ years of age in consideration of root maturation of the adjacent teeth and also patient's behavior. When surgical extraction of supernumerary teeth is postponed, there is possibility that impacted supernumerary teeth in the inverted or horizontal position move toward the nasal cavity, hard palate, or premolar area. When such intraosseous tooth migration is combined with the vertical growth of the maxilla, surgical approach becomes even harder. Therefore, possibility of intraosseous tooth migration should be considered as an important factor when deciding appropriate time for surgical extraction. We are presenting cases of mesiodens which showed intraosseous migration during $6{\sim}7$ years of follow-up period since the first diagnosis had been made at the $2{\sim}3$ years of age.

  • PDF

Enhancement of Chromosome Aberrations in Lymphocytes of Mice after in Vivo Exposure to Chemicals and in Vitro Challenge with Bleomycin (MNNG 또는 Benzo(a)pyrene 유도 염색체 이상에 미치는 Bleomycin의 효과)

  • Heo, M.Y.;Grady, J.J.;Au, W.W.
    • Environmental Mutagens and Carcinogens
    • /
    • v.18 no.2
    • /
    • pp.71-76
    • /
    • 1998
  • Exposure to environmental toxicants can cause cellular problems including the interference of DNA repair processes which may lead to the development of cancer. The existence of toxicant-induced DNA repair abnormality was investigated using mice exposed in vivo to genotoxic chemicals and then challenging their exposed lymphocytes in vitro with bleomycin. The repair of bleomycin-induced DNA damage as estimated by the frequency of chromosome aberrations was determined. Our data indicates that the observed aberration frequencies after in vivo exposure to N-methyl-N'-nitro-N-nitnsoguanidine (MNNG) and in vitro challenge with bleomycin are consistently higher than expected. The enhanced response is not due to the induction of chromosome damage by 25 or 50 mg/kg MNNG since the chemical did not cause chromosome aberrations in lymphocytes of these mice. The observed response after the combined exposure to benzo[a]pyrene (BP) and bleomycin was significantly lower than expected with low in vivo doses of BP (50 mg/kg) and then significantly higher than expected with the high doses (200 mg/kg). We interpret our data to indicate that in vivo exposure to genotoxic agents can cause abnormal DNA repair activities. The response is, however, independent of the clastogenic activities of the inducing chemicals, but dependent upon the inducing agents and on the exposure doses.

  • PDF

Determining the number of Clusters in On-Line Document Clustering Algorithm (온라인 문서 군집화에서 군집 수 결정 방법)

  • Jee, Tae-Chang;Lee, Hyun-Jin;Lee, Yill-Byung
    • The KIPS Transactions:PartB
    • /
    • v.14B no.7
    • /
    • pp.513-522
    • /
    • 2007
  • Clustering is to divide given data and automatically find out the hidden meanings in the data. It analyzes data, which are difficult for people to check in detail, and then, makes several clusters consisting of data with similar characteristics. On-Line Document Clustering System, which makes a group of similar documents by use of results of the search engine, is aimed to increase the convenience of information retrieval area. Document clustering is automatically done without human interference, and the number of clusters, which affect the result of clustering, should be decided automatically too. Also, the one of the characteristics of an on-line system is guarantying fast response time. This paper proposed a method of determining the number of clusters automatically by geometrical information. The proposed method composed of two stages. In the first stage, centers of clusters are projected on the low-dimensional plane, and in the second stage, clusters are combined by use of distance of centers of clusters in the low-dimensional plane. As a result of experimenting this method with real data, it was found that clustering performance became better and the response time is suitable to on-line circumstance.

The viterbi decoder implementation with efficient structure for real-time Coded Orthogonal Frequency Division Multiplexing (실시간 COFDM시스템을 위한 효율적인 구조를 갖는 비터비 디코더 설계)

  • Hwang Jong-Hee;Lee Seung-Yerl;Kim Dong-Sun;Chung Duck-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.61-74
    • /
    • 2005
  • Digital Multimedia Broadcasting(DMB) is a reliable multi-service system for reception by mobile and portable receivers. DMB system allows interference-free reception under the conditions of multipath propagation and transmission errors using COFDM modulation scheme, simultaneously, needs powerful channel error's correction ability. Viterbi Decoder for DMB receiver uses punctured convolutional code and needs lots of computations for real-time operation. So, it is desired to design a high speed and low-power hardware scheme for Viterbi decoder. This paper proposes a combined add-compare-select(ACS) and path metric normalization(PMN) unit for computation power. The proposed PMN architecture reduces the problem of the critical path by applying fixed value for selection algorithm due to the comparison tree which has a weak point from structure with the high-speed operation. The proposed ACS uses the decomposition and the pre-computation technique for reducing the complicated degree of the adder, the comparator and multiplexer. According to a simulation result, reduction of area $3.78\%$, power consumption $12.22\%$, maximum gate delay $23.80\%$ occurred from punctured viterbi decoder for DMB system.