• Title/Summary/Keyword: Combined heat sources

Search Result 34, Processing Time 0.025 seconds

대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building)

  • 변재기;정동화;이종길;홍성호;최영돈;조성환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

가열 수직 평판과 마주보는 전자모듈의 복사 및 대류 냉각에 대한 실험적 고찰 (Experimental Study on the Radiative and Convective Cooling of Electronic Modules opposed to a Heated Vertical Plate)

  • 최인수
    • 한국산업융합학회 논문집
    • /
    • 제8권2호
    • /
    • pp.105-112
    • /
    • 2005
  • The characteristics of natural convection heat transfer combined with radiation in a vertical parallel plates has been investigated experimentally. The vertical channel is consisted with a heated wall and three protruding heating sources attached on the opposite wall. The cooling of modules has been experimented with heating the wall as well as modules themselves at different aspects ratios and heating fluxes. As the location of module is higher, the temperature becomes higher, but the increasement is smaller. When the aspect ratio is lower than 26, its effect on the temperature is not significant rather than that of the radiation heat transfer. Furthermore, the correlation of Nusselt number with the Rayleigh number are attempted, but additional treatment is needed to accomodate the cases of heating module and/or opposite wall.

  • PDF

생석회에 의한 발화 가능성 연구 (A Study on Possibility of fire ignition by Lime(CaO))

  • 노정엽;이의평
    • 한국화재조사학회학술대회
    • /
    • 한국화재조사학회 2011년도 제21회 춘계학술대회
    • /
    • pp.102-116
    • /
    • 2011
  • 구제역 및 AI의 확산으로 전국의 많은 축산농가에 보급되어 있는 생석회(CaO)의 보관방법 잘못으로 인하여 생석회가 화재의 발화원으로 작용한 사례가 다수 존재한다. 화학적으로 생석회가 물과 결합시 발열 한다. 그렇다면 이 발열량이 어떠한 환경과 조건에서 발화원으로 작용하는 것인지 실험을 통하여 알고자 하였다. 이에 인위적으로 형성한 실험조건에서 생석회와 물과의 결합시 발열여부를 확인하고, 발화에 이르는 온도변화 및 발화과정을 실험해 보았다. 그 결과 적당한 수분과 축열조건, 그리고 가연물의 존재가 전제된다면 생석회가 발화원으로 작용할 수 있는 충분한 가능성을 확인하였다. 생석회가 발화원으로 작용한 화재현장의 감식기법으로는 우선 생석회 주변에 물과 가연물질의 존재여부 확인 및 발화장소에서의 수산화칼슘($Ca(OH)_2$)의 존재여부를 확인하는 것이 우선되어야 한다. 이와 같은 실험결과를 바탕으로 제조업체나 농협, 축산농어민 등 제품취급에 관련된 사람에 대한 안전취급 교육을 확행하여 화재를 미연에 방지할 수 있도록 하여야 한다.

  • PDF

에너지 비용을 고려한 중앙냉방시스템 최적운영 방안에 관한 연구(의료시설을 중심으로) (The Study on the Optimal Operation Strategies for Central Cooling System Considering Energy Cost (Focus on a medical facility))

  • 이가람;송재엽
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.1-8
    • /
    • 2020
  • For a central cooling system of a medical facility composed of absorption chiller and screw chiller, the study was conducted on how to minimize the energy cost. In consideration of the energy cost, the optimal operation method in which the operation method of the heat source is changed according to the size of the cooling load was derived through simulation analysis. When applying the optimal operation method, the indoor environment, energy consumption, and energy cost were analyzed and compared with the reference operation method.

태양열 난방 일체형 복합시스템의 축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;고광수;한유리;박윤철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.188-192
    • /
    • 2006
  • This study is conducted to improve efficiency of thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from solar or the others heat sources. However, it has difficulties in storing heat with uniform temperature through the entire tank with respect to vertical direction. This kind of maldistribution of the supplied heat to the storage tank effects on the system performance. In this study is focused on utilization of the thermal stratification to improve thermal comfort for people in the house. To enhance temperature stratification of the tank, a distributor was designed and Installed in the middle of the tank. The distributor is supplies hottest water to the top side of the tank which is very close to inlet of the supply line to the heating load. The hottest water that is accumulated on top side of the tank is firstly supplied to the load with higher temperature. Reminder water takes a little time to warming up until desired supply temperature reached. This kind alternating selection of the supply temperature is improve thermal comfort with moderated system performance.

  • PDF

태양열원 난방기의 수축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델 (Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES)

  • 이승준;김래현
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.99-120
    • /
    • 2017
  • 한국지역난방공사 SS지사에서는 시설용량 전기 99MW, 열 98Gcal/h 규모의 열병합(Combined Heat & Power) 발전소를 구역전기사업으로 운영하고 있다. 이 지역은 경기불황과 수요감소로 하절기 6~9월 사이에 잉여열 처리문제가 발생하여 발전기를 가동하기 곤란한 상황이므로 경제성 있는 에너지 신사업모델 개발이 절실하다. 본 연구에서는 이곳의 실제 운영자료를 기반으로 신재생 에너지 하이브리드 시스템을 도입하여 최적화 운영모델을 개발하고자 한다. 특히 신재생에너지 중에서도 입지제약이 작고 열과 전기를 동시에 생산할 수 있는 연료전지(Fuel Cell)발전과 대표적인 신재생에너지인 태양광(Photovoltaic)발전과 심야발전시 전력을 저장하여 주간에 전력을 방출 할 수 있는 ESS(Energy Storage System)의 조합을 검토하였다. 이에 따른 최적화 모델 선정은 HOMER(Hybrid Optimization of Multiple Energy Resources) 프로그램을 활용하였다. 경제성 분석을 수행한 결과, 순 현재비용(NPC) 측면에서는 기존의 99MW 열병합발전이 가장 경제적이지만 신재생에너지를 사용하여 발생되는 탄소배출권 거래와 REC(Renewable Energy Certificate) 거래를 포함한 측면에서는 99MW의 CHP와 5MW의 연료전지, 521kW의 태양광을 하이브리드 시켜서 전력과 열을 공급하는 것이 99MW의 CHP 열병합발전만으로 전력과 열을 공급하는 것보다 최대 2,475억원 경제적인 것으로 나타났다. 구역전기사업에서 최적화 공정모델로 연료전지와 신재생에너지 하이브리드 시스템을 도입함으로써 경제성을 개선시킬 수 있는 결과를 확인하였다.

산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구 (Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex)

  • 오광민;김래현
    • 에너지공학
    • /
    • 제28권3호
    • /
    • pp.65-79
    • /
    • 2019
  • 본 연구는 산업단지 내 Gas Combined Cycle CHP와 연계 가능한 신재생에너지원을 조합하여 최적의 설비용량을 산정하고자 하였다. 특히 2013~2016년도 에너지사용계획 협의 대상 산업단지 중 집단에너지 공급대상 지역지정 연료사용량 요건은 연간 3.8만 TOE로 미달되지만, 열밀도가 $92.6Gcal/km^2{\cdot}h$로 높은 세종첨단일반산업단지를 연구 대상으로 하였다. 그리고 신재생에너지 Hybrid System 경제성 분석 프로그램인 HOMER Pro를 이용하여 연료전지와 태양광발전을 연계한 FC-PV Hybrid CHP System의 최적화 운영 모델에 대해 분석하였다. 또 CHP의 주 공급 에너지원인 열에너지에 있어, 열수요량 뿐만 아니라 우점 업종에 대한 열수요 패턴을 분석하여 연구의 신뢰도를 높이고자 하였으며, 경제성 분석을 추가하여 상대적 편익을 비교하고자 하였다. 연구 결과, 신규 조성 중인 세종첨단일반산업단지의 전체 간접열 수요는 연간 378,282 Gcal이며, 이중 제지업종이 연간 293,754 Gcal인 약 77.7%를 우점하고 있었다. 산업단지 전체 간접열 수요에 대해 단일 Combined Cycle CHP의 최적 설비용량은 30,000 kW로, 이때 열생산은 CHP가 275,707 Gcal, 72.8 %를 분담하고, 첨두부하보일러 PLB가 103,240 Gcal, 27.2 %를 분담하는 것으로 분석되었다. 그리고 CHP와 연료전지, 태양광 조합에서는 최적 설비용량이 각 30,000 kW, 5,000 kW, 1,980 kW이며, 이때 열생산은 Combined Cycle CHP가 275,940 Gcal, 72.8%, 연료전지가 12,390 Gcal, 3.3%, PLB가 90,620 Gcal, 23.9%를 분담하였다. 여기서 CHP 용량이 감소하지 않은 것은, CHP 용량 감소에 따른 부족한 열 생산량에 대해 PLB의 과다한 운전이 요구되는 경제적이지 못한 대안이 도출되었기 때문이었다. 한편 우점 업종인 제지업종의 간접열 수요에 대해서는 Combined Cycle CHP, 연료전지, 태양광 조합의 최적 설비용량은 25,000 kW, 5,000 kW, 2,000 kW로, 이때 열생산은 CHP 225,053 Gcal, 76.5%, 연료전지 11,215 Gcal, 3.8%, PLB가 58,012 Gcal, 19.7%를 분담하는 것으로 분석되었다. 그러나, 현행 전력시장 및 가스시장에서의 경제성 분석결과는 모두 투자비 회수가 불가능한 것으로 확인 되었다. 다만, 우점 업종인 제지 업종만을 대상으로 CHP와 연료전지, 태양광을 조합한 CHP Hybrid System이 단일 CHP System에 대해 연간 약 93억원의 경영여건을 개선시킬 수 있음을 확인하였다.

A Visualization Scheme with a Calendar Heat Map for Abnormal Pattern Analysis in the Manufacturing Process

  • Chankhihort, Doung;Lim, Byung-Muk;Lee, Gyu-Jung;Choi, Sungsu;Kwon, Sun-Ock;Lee, Sang-Hyun;Kang, Jeong-Tae;Nasridinov, Aziz;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • 제13권2호
    • /
    • pp.21-28
    • /
    • 2017
  • Abnormal data in the manufacturing process makes it difficult to find useful information that can be applied in data management for the manufacturing industry. It causes various problems in the daily process of production. An issue from the abnormal data can be handled by our method that uses big data and visualization. Visualization is a new technology that transforms data representation into a two-dimensional representation. Nowadays, many newly developed technologies provide data analysis, algorithm, optimization, and high efficiency, and they meet user requirements. We propose combined production of the data visualization approach that uses integrative visualization of sources of abnormal pattern analysis results. The perceived idea of the proposed approach can solve the problem as it also works for big data. It can also improve the performance and understanding by using visualization and solving issues that occur in the manufacturing process with a calendar heat map.

EnetPLAN을 이용한 지역난방시스템 가상 운전 분석 (Virtual Analysis of District Heating System Using ENetPLAN)

  • 안정진;이민경;김래현
    • 에너지공학
    • /
    • 제28권3호
    • /
    • pp.18-25
    • /
    • 2019
  • 본 연구에서는 발전사에서 숙련된 사용자가 코드를 입력하여 계산하는 프로그램의 문제점을 해소하고자 광역에너지네트워크 연구단은 확장성을 포함한 누구나 손쉽게 사용할 수 있는 지역난방 운전해석 프로그램 EnetPLAN을 국내 기술로 개발하였다. 이에 EnetPLAN과 시중에서 사용 중인 A프로그램과의 시뮬레이션을 통해 에너지네트워크상의 열원, 열수요 및 CHP(Combined Heat Plant:열병합발전) 운전 결과에 대해 비교하고자 하였다. 그 결과 EnetPLAN과 A프로그램의 에너지네트워크 상의 열 및 전력생산량은 열공급량과 축열조 운영방식의 시뮬레이션 결과에서 대부분 유사한 패턴으로 나타났다. 이는 EnetPLAN이 에너지네트워크 상에 존재하는 열병합발전시설의 다양한 운전모드에 따른 시뮬레이션 적용이 가능함을 확인할 수 있었다. 국내 기술로 개발된 EnetPLAN이 향후 현장에서 쉽게 적용할 수 있으며, 효율적인 운전 시뮬레이션 결과를 제시할 것으로 기대한다.