• Title/Summary/Keyword: Combined filters

검색결과 107건 처리시간 0.025초

저항열을 이용한 간단한 FIR 필터의 설계방법 (Simple desing of FIR filters using resistor array)

  • 김제우;김진규;조민형
    • 전자공학회논문지B
    • /
    • 제31B권9호
    • /
    • pp.22-26
    • /
    • 1994
  • In this paper a method of designing FIR filters without digital arithmetic operationsi is persented. The filter coefficients are represented by resistors combined with a differential amplifier. With this method an FIR filter can be simply impemented without refering to complex digital arithmetic operations. Furthermore, in this scheme, no additional D/A converter is needed for D/A conversion. Spectral response response of a pulse shaping filter of 17 coefficients is shown as an illustration.

  • PDF

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터 (Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages)

  • 이지명;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권5호
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

인덕티브 창 구조를 이용한 VSAT 장비용 도파관형 저손실 대역통과 여파기의 설계 (Design of the waveguide low-loss bandpass filters using the inductive window structures for the VSAT system)

  • 임재봉;박준석
    • 전자공학회논문지A
    • /
    • 제32A권7호
    • /
    • pp.43-50
    • /
    • 1995
  • In this paper, the variational method are used for the filter analysis methods and a CAD program for the design of the waveguide low-loss bandpass filters using inductive window structures for the VSAT(Very Small Aperture Terminal) system has been developed based on the passband correction method combined with fiter synthesis procedures. Using the developed CAD program, 0.01dB equi-ripple chebyshev type 6-section bandpass filters which are sued in the VSAT system operating nationally are designed for the purpose of the Down-link of 12.75~13.25GHz and the Up-link of 14.0~14.5GHz, fabricated and mesured. The measured results are good agreement woth the theoretical resuls.

  • PDF

전원 불평형과 역률을 보상하는 직렬형 능동전력필터 (Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.498-500
    • /
    • 2005
  • This paper presents a unified control scheme for series-type active power filters combined with shunt passive filters for the source voltage unbalance compensation and the power factor correction simultaneously. The power factor correction is achieved by controlling the amplitude of reactive power current in a series filter as zero in a synchronously rotating reference frame. The proposed algorithm successfully compensates the source voltage unbalance and the power factor. The validity of the proposed scheme has been verified by simulation for a 3-kVA hybrid active power filter system.

  • PDF

하천 제방의 영상 점군에서 식생 점 제거 필터링 기법 비교 분석 (Comparative Analysis of Filtering Techniques for Vegetation Points Removal from Photogrammetric Point Clouds at the Stream Levee)

  • 박희성;이두한
    • Ecology and Resilient Infrastructure
    • /
    • 제8권4호
    • /
    • pp.233-244
    • /
    • 2021
  • 본 연구에서는 식생이 무성한 제방의 이상유무 점검을 위한 지상 LiDAR(Light Detection And Ranging) 측량의 적용성을 검토하였다. 지상 LiDAR 측량으로 생성된 제방의 영상 점군 자료에 색상필터 및 형태필터를 적용하여 각 기법별 정확성과 특성을 평가하였다. 임진강 제방의 영상 점군 자료를 이용하여 CIVE, ExG, ExGR, ExR, MExG, NGRDI, VEG, VVI, ATIN, ISL 등의 10가 식생 제거 필터를 적용하였다. 결과에 의하면 정확성은 ISL, ATIN, ExR, NGRDI, ExGR, ExG, MExG, VVI, VEG, CIVE 등의 순서로 나타났다. 색상필터는 지반 구분에 한계를 보였으며 풀꽃을 지반으로 구분하기도 했다. 형태필터는 지반 구분 정확도가 우수하나 거석을 식생으로 인식하는 한계도 보였다. 전체적으로 형태필터가 우수하나 계산 시간에서 10 배 정도 소요되었다. 정확도와 속도 향상을 위해서 형태필터와 색상필터를 결합한 복합필터에 대한 연구가 필요하다.

전기집진 기제를 조합시킨 DPF용 금속 폼 필터의 여과 특성 (Filtration Characteristics of Metal Foam Filters for DPF Combined with Electrostatic Precipitation Mechanism)

  • 박석주;이동근;김진현;조규백;김홍석;정용일
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.151-158
    • /
    • 2007
  • Filtration studies, using simulated test nanoparticles or diesel nanoparticles, have been performed about Inconel foam filters for DPF combined with electrostatic precipitation. The simulated test particles were synthesized by laser ablation in the nitrogen atmosphere at the standard condition. The diesel particles were exhausted from the diesel engine driven on the condition of idle or load mode. Filtration efficiency of the metal foam filter is very low because most of particles are penetrated through the large pores of filter. However, the efficiency was considerably improved by applying the electric field to the filter and/or charging the nanoparticles. Nevertheless, the pressure drop of filter hardly increased because the filter-pores were not clogged by deposited particles and kept open.

수계 장바이러스의 효과적인 농축과 검출방법의 개발 (An Effective Method for the Concentration and Detection of Enteroviruses from Water Samples by Combined Cell Culture-Polymerase Chain Reaction)

  • 장경립;정은영
    • 생명과학회지
    • /
    • 제10권4호
    • /
    • pp.368-373
    • /
    • 2000
  • Enteroviruses in the environment pose a public health risk because they can be transmitted via the fecal-oral route through contaminated water, and low numbers are able to initiate an infection in humans. Because the levels of viruses typically found in environmental water and drinking water are low, they must be concentrated from hundreds to thousands of liters of water. Therefore, the main goal of this study was the development of a rapid, simple and efficient procedure to concentrate, isolate and detect enteroviruses from environmental water samples. Viruses were first concentrated by adsorption to 1 MDS cartridge filter and then eluted with approximately 0.5 liter of 1.5% beef extract/0.05M glycin(pH 9.4). In this study, several procedures to concentrate and purify intact viruses from beef extract obtained from the adsorbent filters were tested. Among them, organic floccuration was the best reliable method for reconcentration. sample volume could be reduced to 200∼400 folds and the efficiency of virus recovery through the procedure was over 72%. Finally, the samples were filtered through a membrane disk filter and then analyzed by either the plaque assay or combined cell culture-polymerase chain reaction.

  • PDF

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구 (Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator)

  • 이철수
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF