• 제목/요약/키워드: Combined cycle unit

검색결과 57건 처리시간 0.023초

IGCC 발전 플랜트에서 복합발전공정-공기분리장치의 연계에 관한 열역학적 성능 평가 (Thermodynamic Performance Evaluation of an Integration Design between the Combined-cycle and Air Separation Unit in an IGCC Power Plant)

  • 원온누리;김현정;박성구;나종문;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.49-51
    • /
    • 2012
  • In this paper, the integration issue, such as an air-side integration design between the gas turbine and air separation unit, is described and analyzed by the exergy and energy balance of the combined-cycle power block in an IGCC power plant. The results showed that the net power of the system was almost same, but that of the gas turbine was decreased as the integration degree increased. The highest exergy loss was occurred in the combustor of gas turbine, which was affected by the chemical reaction, heat conduction, mass diffusion, and viscous dissipation.

  • PDF

복합발전기 조합별 증분비 곡선 재설정에 관한 연구 (A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination)

  • 홍상범;최준호
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

복합열병합 시스템에 대한 열과 전기의 원가산정 (Cost Accounting of Heat and Electricity of a Combined Cycle Cogeneration System)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.560-568
    • /
    • 2005
  • The cost accounting of electricity and heat produced from an energy system is important in evaluating the economical efficiency and deciding the reasonable sale price. The OECOPC method, suggested by the author, was applied to a 650 MW combined cycle cogeneration system having 4 operating modes, and each unit cost of electricity and heat products was calculated. In case that a fuel cost is ${\\}400/kg$ and there are no direct and indirect cost, they were calculated as follows; electricity cost of ${\\}23,700/GJ$ at gas-turbine mode, electricity cost of ${\\}15,890/GJ$ at combined cycle mode, electricity cost of ${\\}14,146/GJ$ and heat cost of ${\\}6,466/GJ$ at cogeneration mode, and electricity cost of ${\\}14,387/GJ$ and heat cost of ${\\}4,421/GJ$ at combined cycle cogeneration mode. Further, these unit costs are applied to account benefit on this system. Since the suggested OECOPC method can be applied to any energy system, it is expected to contribute to cost accounting of various energy systems.

차량용 CO2 에어컨 사이클 성능 향상을 위한 일체형 팽창기-압축기 성능 해석 (An Analysis of the Performance of a Combined Expander-Compressor Unit for a CO2 Automotive Air Conditioning Cycle)

  • 최재웅;임정택;김현진
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.107-115
    • /
    • 2018
  • A design combining the use of a compressor and expander was introduced in order to improve the cycle performance of a $CO_2$ automotive air conditioning system. Both the compressor and expander used were of rotary vane type and were designed to share a common shaft in a housing. Numerical simulation was carried out to evaluate the merit of the combined unit. In a typical automotive air conditioning operating conditions, the COP of the system was improved by 8.7% by the application of the combined unit. The compressor input was reduced by 5.2% through use of the expander output. In addition, about 3.06% increase in the cooling capacity was obtained through isentropic expansion in the expander. Our study noted that, as the pressure difference between the gas cooler and the evaporator becomes larger, the COP of the system improved increases unless the mass flow rate in the expander exceeds that in the compressor.

복합열병합 발전에 대한 전기 및 열 원가산정 (Cost Accounting of Electricity and Heat on Combined Cycle Cogeneration)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.673-682
    • /
    • 2004
  • The cost accounting of products on energy system is important for evaluating the economical efficiency and deciding the reasonable sale price. In the present, the suggested OECOPC method was applied to a combined cycle cogeneration, and each unit cost of electricity and heat products was calculated. In addition, the previous thermoeconomic methods were applied and calculated to equal system. As a result of comparing various methods, the unit costs by OECOPC method were calculated in the middle value of those. This result tells that OECOPC methods are most moderate. The suggested OECOPC method can apply any energy system. Hence this method is expected to make contribution to cost accounting on energy System.

가족생활주기별 아파트 단위주호 계획요소 선호분석 (An Analysis of the Preferential Unit Planning Components of High-rise Residential Buildings Across Family Life Cycle Stages)

  • 이연숙;이현정;이지영
    • 한국실내디자인학회논문집
    • /
    • 제14권2호
    • /
    • pp.120-127
    • /
    • 2005
  • The purpose of this study was to examine preferential unit planning components of high-rise residential buildings across family life cycle stages. The questionnaire survey was adopted in this study, and 110 cases were used for data analysis. Based on the age of the oldest child, the family life cycles used in the study were divided into four stages: early childhood, elementary school, adolescence, and adulthood. The findings showed that the preference of the unit planning components across the stages was distinct; families in the stage of early childhood and adolescence had the growing needs for spatial features, and regarded living-related features as important. Families in the stage of adulthood tended to have larger spaces. It was noticed that unit planning components needed to be more differential when the combined effect of both family life cycle stages and housing size was considered.

통합적 엑서지에 의한 발전 플랜트의 열경제학적 해석 (Thermoeconomic Analysis of Power Plants with Integrated Exergy Stream)

  • 김덕진;이현수;곽호영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.871-878
    • /
    • 2000
  • Exergetic and thermoeconomic analysis were performed for a 500-MW combined cycle plant and a 137-MW steam power plant without decomposition of exergy stream of matter into thermal and mechanical exergies. The calculated costs of electricity are almost same within 0.5% as those obtained by the thermoeconomic method with decomposition of exergy into thermal and mechanical exergies of the combined cycle plant. However for the gas-turbine cogeneration plant having different kinds of products. the difference in the unit costs of products, obtained from the two methodologies is about 2%. Such outcome indicates that the level at which the cost balances are formulated does not affect the result of thermoeconomic analysis, that is somewhat contradictory to that concluded previously.

  • PDF

복합계통 개조를 위한 가스화 폴리제너레이션 시뮬레이션 연구 (Numerical Study on a Poly-Generation Based on Gasification for Retrofit of a Natural Gas Combined Cycle)

  • 서동균;주용진;홍진표;김경래;이정박
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.141-146
    • /
    • 2017
  • In this work, a simulation study on net 500 MW class of Poly-Generation was conducted for the retrofit of an aged natural gas combined cycle. An entrained gasifier which has a capacity of maximum $260,000Nm^3/h$, 50 MW class of a Polymer Electrolyte Membrane Fuel Cell, and H-class Gas Turbine were selected as key processes. After unit design for those employed processes was set up and combined, the simulation was carried out with Gate-Cycle software (Ver. 6.0) for two cases. The selected cases are a retrofit type (Poly-Gen 1) and a new type (Poly-Gen 2). It was found that the efficiency of the retrofit case is 2.7% lower than that of the new case.

로직에 기반 한 트리 구조의 퍼지 뉴럴 네트워크를 이용한 복합 화력 발전소의 출력 예측 (Output Power Prediction of Combined Cycle Power Plant using Logic-based Tree Structured Fuzzy Neural Networks)

  • 한창욱;이돈규
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.529-533
    • /
    • 2019
  • 오늘날 복합 화력 발전소는 전력 생산을 위해 많이 사용되고 있고, 최근에는 운전 매개 변수를 기반으로 발전 출력을 예측하는 것이 주요 관심사이다. 본 논문에서는 복합 화력 발전소의 출력을 예측하기 위해 컴퓨터 지능 기법을 이용하는 방법을 제시한다. 컴퓨터 지능 기술은 지속적으로 발전되어 많은 실제 문제에 적용되어 왔다. 본 논문에서는 트리 구조의 퍼지 뉴럴 네트워크를 이용하여 발전 출력을 예측하고자 한다. 트리 구조의 퍼지 뉴럴 네트워크는 퍼지 뉴런을 노드로 선택하고 관련 입력을 최적으로 선택하여 규칙 수를 줄이는 장점이 있다. 네트워크의 최적화를 위해 2 단계 최적화 방법이 사용된다. 유전 알고리즘은 최적의 노드와 리프를 선택하여 네트워크의 이진 구조를 최적화 한 다음 랜덤 신호 기반 학습을 수행하여 최적화 된 이진 연결을 단위 구간에서 미세 학습한다. 제안 된 방법의 유용성을 검증하기 위해 UCI Machine Learning Repository Database에서 얻은 복합 화력 발전소 데이터를 사용한다.