• 제목/요약/키워드: Combined cooling

검색결과 254건 처리시간 0.028초

공냉-수냉 혼합냉각계통 개발 (Development of an Air-Water Combined Cooling System)

  • 권태순;배성원
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.84-88
    • /
    • 2014
  • A long term passive cooling system is considered as the most important safety feature for the nuclear design after the Fukushima Daiichi nuclear power plant accident in 2011. The conventional active pump driven safety systems are not available during a station Black Out (SBO) accident. The current design requirement on cooling time of the Passive Auxiliarly Feedwater System (PAFS) is about 8 hours only. To meet the 72 hours cooling time, the pool capacity of cooling water tank should be increased as much as 3~4 times larger than that of current water cooling tank. In order to extend the cooling time for 72 hours, a new passive air-water combined cooling system is proposed. This paper provides the feasibility of the combined passive air-water cooling system. The current pool capacity of water cooling system is preserved, and the cooling capability is extended by an additional air cooler.

냉각공기 예냉각을 통한 가스터빈 설계변수 변화에 의한 복합발전시스템 성능향상 분석 (Analysis of Performance Enhancement of a Combined Cycle Power Plant by the Change of Design Parameters of Gas Turbine Using Coolant Pre-cooling)

  • 권현민;김동섭;강도원;손정락
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.61-67
    • /
    • 2016
  • Turbine blade cooling is one of the major technologies to enhance the performance of gas turbine and combined cycle power plants. In this study, two cases of coolant pre-cooling schemes were applied in combined cycle power plant: decrease of coolant mass flow needed to cool turbine blade and increase of turbine inlet temperature (TIT). Both schemes are benefited by the decrease of coolant temperature through coolant pre-cooling. Under the same degree of pre-cooling, increasing TIT exhibits larger plant power boost and higher plant efficiency than reducing coolant flow. As a result, the former produces the same gas turbine power with a much smaller degree of pre-cooling than the latter. Another advantage of increasing TIT is a higher plant efficiency. Even with an assumption of partial achievement of the theoretically predicted TIT, the method of increasing TIT can provide considerably larger power output.

The combined effect of extraoral vibratory stimulus and external cooling on pain perception during intra-oral local anesthesia administration in children: a systematic review and meta-analysis

  • Tirupathi, Sunny Priyatham;Nanda, Neethu;Pallepagu, Sneha;Malothu, Sardhar;Rathi, Nilesh;Chauhan, Rashmi Singh;Priyanka, VakaJeevan;Basireddy, Rameshreddy
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.87-96
    • /
    • 2022
  • This study aimed to assess the combined use of extraoral vibratory stimulation and extraoral cooling in reducing the pain (subjective and objective) of dental local anesthesia administration in children. PubMed, Cochrane Central Register of Controlled Trials, and Ovid SP databases were searched up to July 2021. Article titles were screened and full-text evaluations of the selected articles were performed. Finally, seven studies (391 children, aged 4 - 12 years) were included in this qualitative and quantitative analysis. The pooled data determined the combined effect of extraoral vibration and extraoral cooling as a single measure. Extraoral vibration or cooling alone were not compared. The measured primary and secondary outcomes were pain perception and subjective and objective pain, respectively. When compared with the control, extraoral vibration and cooling resulted in significant differences in the mean combined data for the variables, pain perception, and pain reaction. Children's subjective pain as measured by pain scores were reduced when extraoral vibration and cooling was used during local anesthesia administration (mean difference -3.52; 95% confidence interval [-5.06 - 1.98]) and objective pain (mean difference -1.46; 95% confidence interval [-2.95 - 0.02] ; mean difference -1.93; 95% confidence interval [-3.72 - 0.14]). Within the confines of this systematic review, there is low-quality evidence to support the use of combined extraoral vibration and cooling for reducing pain (subjective and objective) during intraoral local anesthesia administration in children.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화 (Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating)

  • 권익환;강도원;김동섭;김재환
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

가스터빈 복합발전의 기동특성을 고려한 열거래 기반 지역 냉난방 시스템의 최적 운영 모델 (Optimal Operation Model of Heat Trade based District Heating and Cooling System Considering Start-up Characteristic of Combined Cycle Generation)

  • 김종우;이지혜;김학만
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1610-1616
    • /
    • 2013
  • Recently, district heating and cooling (DHC) systems based on combined cycle generation (CCG) providers are increasing in Korea. Since characteristics of combined heat and power (CHP) generators and heat demands of providers, heat trading between DHC providers based on the economic viewpoint is required; the heat trading has been doing. In this paper, a mathematical model for optimal operation based on heat trading between DHC providers is proposed. Especially, start-up characteristic of CCG is included. The operation model is established by mixed integer linear programming (MILP).

Evaluation by Rocket Combustor of C/C Composite Cooled Structure for Combined-cycle Engine

  • Takegoshi, Masao;Ono, Fumiei;Ueda, Shuichi;Saito, Toshihito;Hayasaka, Osamu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.804-809
    • /
    • 2008
  • In this study, the cooling performance of a C/C composite material structure with metallic cooling tubes fixed by elastic force without chemical bonding was evaluated experimentally using combustion gas in a rocket combustor. The C/C composite chamber was covered by a stainless steel outer shell to maintain its airtightness. Gaseous hydrogen as a fuel and gaseous oxygen as an oxidizer were used for the heating test. The surface of these C/C composites was maintained below 1500 K when the combustion gas temperature was about 2900 K and heat flux to the combustion chamber wall was about 9 $MW/m^2$. No thermal damage was observed on the stainless steel tubes which were in contact with the C/C composite materials. Results of the heating test showed that such a metallic-tube-cooled C/C composite structure is able to control the surface temperature as a cooling structure(also as a heat exchanger), as well as indicating the possibility of reducing the amount of the coolant even if the thermal load to the engine is high. Thus, application of the metallic-tube-cooled C/C composite structure to reusable engines such as a rocket-ramjet combined cycle engine is expected.

  • PDF

냉각공기의 예냉각이 가스터빈 복합발전 성능에 미치는 영향 (Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle)

  • 권익환;강도원;강수영;김동섭
    • 대한기계학회논문집B
    • /
    • 제36권2호
    • /
    • pp.171-179
    • /
    • 2012
  • 고온부에 해당하는 터빈 노즐과 로터의 냉각은 가스터빈의 성능에 큰 영향을 미친다. 본 연구에서는 냉각 공기의 예냉각이 가스터빈과 복합화력 발전 성능에 미치는 영향을 알아보았다. 계산에 사용된 모델은 F-Class 가스 터빈이며 냉각을 고려한 터빈의 구성요소를 사용해 냉각공기의 변화에 대해 보다 정확한 모사를 구사하였다. 냉각공기의 예냉각에 따른 가스터빈의 성능변화를 나타내기 위해 탈설계 해석이 수행되었다. 노즐 및 로터의 냉각에 따른 성능 변화를 보다 정확하게 나타내기 위해 열역학적 냉각모델과 속도삼각형을 고려한 모델이 고려되었다. 또한 복합발전의 경우 냉각공기에서 추출된 열을 하부사이클에서 회수하여 스팀터빈을 구동하는데 추가적인 열을 공급하는 시스템이 구성되었다. 복합발전 시스템의 모든 냉각공기의 온도를 200K 예냉각하는 경우에 주유동가스의 유량증가로 인해 약 1.78%의 출력 증가를 나타내었으며 동일한 터빈 입구온도 유지를 위한 연료소모의 증가로 효율은 0.70% 포인트 감소하였다.

중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구 (A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System )

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

A Combined Effect of Differential Cooling and Topography on the Formation of Ulleung Warm Eddy

  • SEUNG Young Ho;NAM Soo Yong;LEE Sang Yong
    • 한국수산과학회지
    • /
    • 제22권6호
    • /
    • pp.375-384
    • /
    • 1990
  • A numerical experiment is made to study the combined effect of differential cooling and bottom topography on the formation of Ulleung Warm Eddy. The Ulleung Warm Eddy appears after the passage around the Ulleung Basin of coastal trapped baroclinic waves generated in the north initial density front to the north, the continental slopes both to the west and south, and the Yamato Rise to the east. It resides therefore always inside the Ulleung Basin, as confirmed by observations.

  • PDF