• Title/Summary/Keyword: Combined approach

검색결과 1,691건 처리시간 0.031초

ESGA를 이용한 불평형 배전계통의 커패시터 설치에 관한 연구 (A Study on Capacitor Placement Using ESGA Hybrid Approach in Unbalanced Distribution Systems)

  • 김규호;이유정;이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.316-324
    • /
    • 2003
  • This paper applied Elite-based Simplex-GA hybrid approach combined with Muptipop-GA (ESGA) to determining the location, size and number of capacitors to improve voltage profile and minimize power losses in unbalanced distribution systems. One of the main obstacles in applying GA to complex problems has been the high computational cost due to their slow convergence rate. To alleviate this difficulty, ESGA approach was developed that combines Elite-based Simplex-GA hybrid approach with Muptipop-GA. The objective function formulated consists of two terms: cost for energy losses and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as a step function due to banks of standard discrete capacities. Its efficiency was proved through the application in IEEE 13 bus and 34 bus test systems and was compared with several methods using GA.

경추간판탈출증에 대한 미세 전측방 Tunnel Approach의 결과 (Results of Microsurgical Anterolateral Tunnel Approach for Cervical Disc Herniation)

  • 장우영;김근수;이정청;김철진;최하영;현수남;한동한
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권5호
    • /
    • pp.600-604
    • /
    • 2001
  • Objective : The authors report the microsurgical anterolateral tunnel approach for the treatment of the cervical disc diseases and its postoperative surgical results. Methods : All surgical procedures followed the method of classical microsurgical anterior discectomy. Small tunnel(7-8mm) was made on the disc space reaching to the posterior longitudinal ligament. The disc materials and bony spurs were removed through this tunnel. Thirty-one patients of cervical disc herniation(24 cases with pure disc herniation, 7 cases with combined cervical spondylosis) were evaluated on the symptoms, conformation in plain X-ray, C-T, and MRI. The follow up time was over 2 years. Results : Postoperatively the result(following the out come scale) was excellent and good in Twenty-nine patients. One with fair result showed remnant disc particle and spur and another one is combined with cord contusion. One patient with lesion in C 3-4 space and two cervicothoracic junction showed excellent result. Two patients with osteoporosis also showed good results. Cervical spine curvature and disc space height were not changed on the plain X-ray and MRI in all patients. Twenty-nine patients were discharged within 3 days after surgery without any postoperative complications. Conclusions : The microsurgical anterolateral tunnel approach could be indicated for the treatment of patients with cervical disc diseases and with difficulty in achieving interbody fusion(the higher cervical level and cervicothoracic junction, osteoporosis etc.).

  • PDF

Versatile midfacial degloving approach in oral and maxillofacial surgery

  • Anunay, Pangarikar;Umamaheswari, G.;Prachi, Parab;Suresh, Kumar;Devarathnamma, M.V.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.192-198
    • /
    • 2019
  • Objectives: Oral and maxillofacial surgeons must gain mastery of various approaches to the midface due to the increasing incidence, complexity, and severity of presenting midfacial fractures. Unlike in the case of other body parts, the need to preserve facial aesthetics makes it more difficult for the surgeon to select an approach for managing the facial injuries. The midfacial degloving (MFD) approach is a combination of intraoral and intranasal incisions made to access the midface without any external incision. The aim of the present study was to evaluate the efficacy of MFD in maxillofacial surgery and to assess its advantages and complications. Materials and Methods: The MFD approach was used in five cases, with three cases treated with open reduction and internal fixation and two cases operated on for posttraumatic deformity. Nasal dorsum augmentation was completed in three cases and nasal osteotomy was performed in one case. The bicoronal flap technique was combined with MFD for frontal bone augmentation in one case. The intraoperative time required for flap completion and the ease of performing the planned procedures were noted. Postoperative evaluation was done for reduction, aesthetics, function, and complications. Results: Access was excellent for performing all planned procedures. Average time spent for flap elevation and exposure of the midface was 63 minutes. Complications like postoperative swelling, infraorbital nerve paresthesia, and intranasal crusting were all transient. No long-term complications like stenosis of the nose, sneer deformity, or weakness of the facial muscles were noticed. Additionally, no complications were noted when MFD was combined with bicoronal flap. Conclusion: Though the MFD approach is technically demanding and takes more time than other facial approaches, it should be learned and applied by maxillofacial surgeons in selective cases, as it provides complete exposure of the midface without facial scarring.

원주방향 부분 관통 균열이 존재하는 직관에 인장하중과 열하중의 복합하중이 가해지는 경우의 균열 선단 응력장 (Crack-tip Stress Field of Fully Circumferential Surface Cracked Pipe Under Combined Tension and Thermal Loads)

  • 제진호;김동준;김윤재
    • 대한기계학회논문집A
    • /
    • 제38권11호
    • /
    • pp.1207-1214
    • /
    • 2014
  • 균열이 존재하는 구조물의 균열 선단에서 과도한 소성 상태에 도달하게 되면 파괴역학 매개변수에 의하여 예측되는 균열 선단의 응력장이 실제와는 매우 다르게 나타난다. 구조물의 크기와 형상 그리고 하중의 형태에 따라 균열 선단의 응력장이 유일하지 않다. 이는 균열 선단의 구속 효과가 단일 매개변수 파괴역학으로 표현 될 수 없기 때문이다. 따라서 전통적으로 사용되었던 K, J를 이용한 단일 매개변수 파괴역학을 보완하기 위하여 다양한 시도가 있었고, 대표적으로 Q-응력이 있다. 본 논문에서는 Q-응력을 이용하여 원주방향으로 완전히 발달한 표면 균열이 있을 경우의 균열 선단의 구속 효과를 확인하였다. 고려된 하중은 일차하중으로 축 방향 인장하중과 반경방향 열구배에 의한 이차하중의 복합하중이다. 이차하중이 일차하중보다 구속효과가 더 심하며 기계하중보다 열하중이 뒤에 가해지는 열충격조건에서 구속효과가 더 심하게 나타남을 확인하였다.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

A new model for T-shaped combined footings part II: Mathematical model for design

  • Luevanos-Rojas, Arnulfo;Lopez-Chavarria, Sandra;Medina-Elizondo, Manuel
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.61-69
    • /
    • 2018
  • The first part shows the optimal contact surface for T-shaped combined footings to obtain the most economical dimensioning on the soil (optimal area). This paper presents the second part of a new model for T-shaped combined footings, this part shows a the mathematical model for design of such foundations subject to axial load and moments in two directions to each column considering the soil real pressure acting on the contact surface of the footing with one or two property lines restricted, the pressure is presented in terms of an axial load, moment around the axis "X" and moment around the axis "Y" to each column, and the methodology is developed using the principle that the derived of the moment is the shear force. The classic model considers an axial load and a moment around the axis "X" (transverse axis) applied to each column, i.e., the resultant force from the applied loads is located on the axis "Y" (longitudinal axis), and its position must match with the geometric center of the footing, and when the axial load and moments in two directions are presented, the maximum pressure and uniform applied throughout the contact surface of the footing is considered the same. To illustrate the validity of the new model, a numerical example is presented to obtain the design for T-shaped combined footings subjected to an axial load and moments in two directions applied to each column. The mathematical approach suggested in this paper produces results that have a tangible accuracy for all problems.

복합하중이 작용하는 국부감육배관 평가법 개발 (Development of Assessment Methodology for Locally Wall-Thinned Pipe Under Combined Loading)

  • 심도준;김윤재;김영진;박치용
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1399-1406
    • /
    • 2005
  • Recently authors have proposed a new method to estimate failure strength of a pipe with local wall thinning subject to either internal pressure or global bending. The proposed method was based on the equivalent stress averaged over the minimum ligament in the locally wall thinned region, and the simple scheme to estimate the equivalent stress in the minimum ligament was proposed, based on the reference stress concept. This paper extends the new method to combined internal pressure and global bending. The proposed method is validated against FE results for various geometries of local wall thinning under combined loading. The effect of internal pressure is also investigated in the present study. Comparison of maximum moments, predicted according to the proposed method, with published full-scale pipe test data fur locally wall-thinned pipes under combined internal pressure and global bending, shows good agreement.

Unsigned와 signed 겸용 병렬 제곱기의 설계 (Design of combined unsigned and signed parallel squarer)

  • 조경주
    • 스마트미디어저널
    • /
    • 제3권1호
    • /
    • pp.39-45
    • /
    • 2014
  • 제곱연산은 승수와 피승수가 동일한 곱셈의 특수한 경우로 병렬 제곱기의 부분곱 행렬에서 부분곱 비트들은 대칭을 이룬다. 이런 특성을 이용하여 부분곱을 폴딩(folding), 쉬프트, 재배열하여 부분곱 비트의 수와 부분곱 행렬의 최대높이들 감소시킨다. 본 논문에서는 제어신호에 따라 unsigned와 signed 제곱기로 동작하는 겸용 제곱기의 효율적인 설계 방법을 제안한다. 기존 겸용 제곱기와 달리 자리수(weight)가 다른 특정 부분곱 비트들의 덧셈에 대해 덧셈기를 사용하지 않고 계산하는 방법을 제안한다. 시뮬레이션을 통해 제안한 겸용 제곱기는 기존 겸용 제곱기와 비교하여 면적은 약 18%, 지연시간(propagated delay time)은 약 11%, 전력소모는 약 9% 감소시킬 수 있음을 보인다.

상·하향 통합모형을 활용한 농업 수자원 부족의 경제적 효과 분석 (Economic Impacts of Agricultural Water Shortages in Korea - A Combined Top-down and Bottom-up Model Analysis -)

  • 이승호;권오상;강성원
    • 농촌계획
    • /
    • 제23권4호
    • /
    • pp.111-126
    • /
    • 2017
  • This study analyzes the impacts of agricultural water shortages in Korea using a combined top-down and bottom-up model. A multi-region multi-output agricultural sector model with detailed descriptions of production technologies and water and land resource constraints has been combined with a standard CGE model. The impacts of four different water shortage scenarios were simulated. It is shown that an active adaptation of crop choices occurs in even the regions with relatively abundant water resources in order to respond to the change in relative output prices caused by water shortages. We found that although the losses in production values are not quite large despite water shortages due to the price feedbacks, the loss in GDP is substantial. We show that our combined approach has advantages in deriving region and product specific production effects as well as the overall GDP loss effect of water shortages.

자기연상 다층 퍼셉트론을 이용한 키 스트로크 기반 사용자 인증 (Keystroke Dynamics based User Authentication with Autoassociative MLP)

  • Sungzoon Cho;Daehee Han
    • 한국정보보호학회:학술대회논문집
    • /
    • 한국정보보호학회 1997년도 종합학술발표회논문집
    • /
    • pp.345-353
    • /
    • 1997
  • Password checking is the most popular user authentication method. The keystroke dynamics can be combined to result in a more secure system. We propose an autoassociator multilayer perceptron which is trained with the timing vectors of the owner's keystroke dynamics and then used to discriminate between the owner and an imposter. An imposter typing the correct password can be detected with a very high accuracy using the proposed approach. The approach can also be used over the internet such as World Wide Web when implemented using a Java applet.

  • PDF