• 제목/요약/키워드: Combined Sewer Overflow(CSO)

검색결과 14건 처리시간 0.029초

합류식 월류수와 분류식 우수유출수의 비점오염물질 유출특성 비교 (Comparison of Characteristics of Nonpoint Source Pollution from Separate and Combined Sewer System)

  • 신민환;전지홍
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.97-106
    • /
    • 2017
  • In this study, the characteristics of nonpoint source pollutant loads from separate sewer overflow (SSO) and combined sewer overflow (CSO) were evaluated during 2016 in Namyangju city, Korea. Five rainfall events were monitored during 2016 with ranging from 14.5 mm to 121.5 mm. The runoff ratio of CSO was higher than that of SSO because only design volume of maximum sanitary sewer ($1Q_h$) was transported and treated and $2Q_h$ was overflowed to waterbody during rainy day although combined sewer system was designed to transport $3Q_h$ to treatment system. The event mean concentrations (EMCs) and pollutant loads from CSO were higher than those from SSO. BOD and COD of CSO, and TOC and TN of SSO represented distinct first flush phenomena. The inadequate management in combined sewer system from which the untreated $2Q_h$ from CSO was overflowed to waterbody during rainy day could influence on high pollutant loads and first flushing. Treating $2Q_h$ from CSO, source control such as low impact development, and treating outflow from SSO were strongly recommended to control non-point source pollution in urban area.

A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM

  • Kim, Jae-Hoon;Paik, Do-Hyeon
    • 한국환경보건학회지
    • /
    • 제31권6호
    • /
    • pp.467-474
    • /
    • 2005
  • The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration. Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the $80-90\%$ of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.

장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구 (Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation)

  • 이건영;나용운;류재나;오재일
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.785-794
    • /
    • 2013
  • 합류식하수관로시스템에서 강우시 유출수는 관로내 퇴적물과 지표면 세척효과에 의한 오염물질 등이 혼합되어 하천으로 방류되기 때문에 방류수계에 화학적 물리적 생물학적으로 상당한 문제를 야기하지만, 현재 국내에서는 CSOs의 오염 부하량 관리기준을 결정함에 있어 통일된 방법론이 부재한 실정이다. 이에 따라 본 연구에서는 우수유출모형을 활용한 장기간 CSOs 유량-수질모의를 통하여 CSOs의 오염부하량 저감목표를 설정하고자 한다. 이를 위하여 국내외 CSOs 관리기준을 검토하였으며, 그 결과 연간 총 월류부하량 및 발생빈도를 총 2단계로 구분하여 관리하고, 1단계에서는 60%, 2단계에서는 85%를 저감하는 것을 목표로 설정하였다. 도출된 저감 목표 기준을 대상지역에 적용하여 장기간(최소 10년간)의 CSOs 발생 모의를 바탕으로 분석한 결과, BOD 월류부하량 저감목표는 1단계 1,123 kg, 2단계 2,374 kg이었으며, 목표 달성을 위해 대응해야 할월류량은 1단계 $11,685m^3$, 2단계 $24,701m^3$으로 나타났다.

합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안 (Effect and Control of the Sediment in the Combined Sewer on CSOs)

  • 임봉수;김도영;이광춘
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

하수의 화학적 응집조건 및 응집제별 응집효율 분석 (Chemical Coagulation Conditions and Efficiency of Sewage with Al(III) and Fe(III) Coagulants)

  • 박준규;전동걸;박노백;전항배
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.463-474
    • /
    • 2010
  • In this study, chemical coagulation conditions for treating combined sewer overflow(CSO) occurred during rainy season were evaluated by jar tests with aluminum sulfate[$Al_2(SO_4)_3{\cdot}17H_2O$] and ferric chloride[$FeCl_3{\cdot}6H_2O$]. The raw domestic sewage sampled from the primary sedimentation tank at a local sewage treatment plant was filtered through $150{\mu}m$ sieve before using. Point of zero charge(PZC) for various dose of aluminum sulfate occurred at pH 5.8-6.5, while for ferric chloride occurred at pH 5.3-6.0 in term of streaming current(SC) values. Charge neutralization ability of aluminum sulfate was bigger than that of ferric chloride. Optimum pH and dose of aluminum sulfate and ferric chloride were 6.2, 0.438mM and 5.8, 0.925mM, respectively. Removal efficiencies of TCOD, turbidity, SS and TP were 75, 97, 95, 96% with aluminum sulfate and 74, 96, 98, 99% with ferric chloride at their optimum coagulation conditions. More efficient removal of SS, TP and small particles was possible with ferric chloride at optimum coagulation conditions. Both SC values and COD removal started to increase where soluble phosphorus was completely removed.

소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향 (Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow)

  • 김상현
    • 대한환경공학회지
    • /
    • 제36권10호
    • /
    • pp.685-690
    • /
    • 2014
  • 하수처리시설 초과유량에 대한 처리 규제 입법 예고로 인해 강우 월류수 처리에 대한 관심이 증가하고 있다. 본 연구에서는 강우 월류수 염소(차아염소산나트륨) 소독 시 소독제 농도(0.11-4.0 mg $Cl_2/L$), pH (6.5-8.0), 온도($15-25^{\circ}C$), 암모니아 농도(10-41 mg N/L), 부유물질(91-271 mg SS/L)이 대장균군수 감소 속도에 미치는 영향을 고찰하였다. 차아염소산나트륨 농도 효과는 반속도 상수가 1.212mg $Cl_2/L$인 saturation-type model로 잘 모사되었다. 소독 반응 속도는 SS와 pH 증가에 따라 감소되는 반면, 온도에 따라서는 증가하였고, 암모니아 농도에는 영향을 받지 않았다. 월류수 유입 조건을 $1{\times}10^5MPN/mL$, 271 mg SS/L, $15^{\circ}C$, pH 8.0로 가정할 때, 염소 주입 농도 1 mg/L, 수리학적 체류시간 1.25 분인 염소 소독조를 통해 입법예고 된 수질 기준의 1/3 수준인 대장균군수 1,000개/mL를 달성할 수 있을 것으로 계산되어, 염소 소독이 강우 월류수 소독에 유효하게 사용될 수 있을 것으로 판단된다.

우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구 (Criteria for calculation of CSO volume and frequency using rainfall-runoff model)

  • 이건영;나용운;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

하수저류시설 운영 전략 연구 (Operation Strategy for a Multi-functional Storage Facility)

  • 윤소영;임윤대;오재일
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.959-970
    • /
    • 2011
  • The frequent occurrence of sewer flooding and the intermittent discharge of non-point pollutions into the receiving water body are emerging issues recently due to the climate change and urbanization. These problems might be solved by introducing a multifunctional storage facility. Unlike a single-purpose storage facility, a multi-purpose storage facility should be operated at an instant to meet for flood prevention, reduction of non-point pollution and/or rainwater reuse. Considering various operational combinations it is suggested that prevention of sewer flooding coupled with reduction of non-point pollution is the most effective operational strategy for a multi-functional storage facility.

합류식하수도 월류수 관리를 위한 초기우수 저류조 설계방안 연구 (A Study on First Flush Storage Tank Design for Combined Sewer Overflows (CSOs) Control)

  • 손봉호;어성욱
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.654-660
    • /
    • 2011
  • One of the best way to control Combined Sewer Overflow (CSO) is proposed to construct first flush storage tank. But there is little known parameters for optimum design of these facilities. This study was conducted to get optimum design parameters for a first flush storage tank construction. The optimization of the tank is generally based upon some measure of SS(Suspended Solid) mass holding efficiency. Water quality deterioration of receiving water body happened right after first time occurring rainfall in dry weather seasons. So, design rainfall intensity is used at 2 mm/hr for peak of monthly average intensities of dry seasons. The capacities for each evaluated catchment are designed from 14.4 min to 16.1 min HRT of CSOs flow at design rainfall intensity. Owing to all storage tanks are connected to interception sewer having a redundancy, the suggested volume could be cut down.

하수저류시설 타당성 분석 연구 (Feasibility Study on Installing a Multi-functional Storage Facility)

  • 류재나;오재일;이경용
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.935-947
    • /
    • 2011
  • In the era of climate change, the feasibility of a 'multi-functional storage facility' was evaluated in terms of various key performance indices such as flooding prevention effects, urban pollution reduction effects, and rainwater harvesting effects. As a result, the Korea Ministry of Environment introduced a new concept of 'multi-functional storage facility' for sewer flooding prevention and urban non-point pollution reduction. Prior to introducing these infrastructure (a large underground storage facility), the more details were needed to be examined carefully in all of technical aspects of construction and management. It was also well known that the validity of installation of 'multi-functional storage facility' was sometimes weakened because of a low B/C ratio.