• Title/Summary/Keyword: Combined Point

Search Result 1,043, Processing Time 0.026 seconds

Plan of Information System for Combined Treatment of the Oriental and the Western Medicine (한.양방 협진 정보시스템 구축방안 연구)

  • Yea, Sang-Jun;Jang, Hyun-Chul;Kim, Chul;Kim, Jin-Hyun;Kim, Sang-Kyun;Song, Mi-Young
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2009
  • Background : Recently, Medical Act was amended to encourage the induction of combined treatment between Oriental Medicine doctors and Western doctors. As yet, the information infra for combined treatment has not been studied. Objectives : This study aimed to design the architecture of information system for combined treatment of the Oriental and the Western Medicine. Methods : First, we defined the information of combined treatment through the analysis of research trends from the inside and outside of the country. Because the data compatibility is very important, the definition of information must be ahead of anything else. Second, we designed the architecture of information system based on the prior definition. Results : We classified the information for combined treatment by subject such as law, clinic, research, manpower, facilities, and education. In this paper information system examined in three aspects. First the infra layer is organized as hardware, netware, and security. Second is data warehouse layer for the storing, filtering, and extraction of data. Third is service layer which is related to data transmission. And Finally all information for combined treatment is provided through the portal system for medical consumer, political planner, and R&D researcher. Conclusion : In this paper, we studied the essential factors of combined treatment information in the view point of information system. But the detailed design and implementation of information system must be followed to effect this results.

  • PDF

Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines (345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향)

  • Lee, Jong-Beom;Jung, Chae-Kyun;Lim, Kwang-Sik;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

A Study on Reclosing Decision on 154kV Combined Transmission Lines (154kV 혼합송전선로 재폐로 결정에 관한 연구)

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1761-1769
    • /
    • 2010
  • This paper describes switching surge analysis on reclosing decision in 154kV combined transmission line with power cables. Reclosing should be operated in combined transmission line based on the technical evaluation because of insulation problem of power cable section. If the surge strikes on power cable, the breakdown can occur at week point of cable insulation. Therefore the detailed analysis is required by considering several conditions such as length ratio of power cable, arrester, fault resistance, charging rate and grounding resistance, etc.. In addition, sheath voltage on IJ(Insulated Joint) is analyzed to confirm the protective level. Simulation is performed by EMTP/ATP. Analysis results show that reclosing can be operated without any special problem by the single line-to-ground fault with fault resistance of $1\Omega$ to $50\Omega$ occurred at the overhead transmission section in 154kV combined transmission lines and trap charge of 100% and 110%.

Comparison of Characteristics of Nonpoint Source Pollution from Separate and Combined Sewer System (합류식 월류수와 분류식 우수유출수의 비점오염물질 유출특성 비교)

  • Shin, Min Hwan;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.97-106
    • /
    • 2017
  • In this study, the characteristics of nonpoint source pollutant loads from separate sewer overflow (SSO) and combined sewer overflow (CSO) were evaluated during 2016 in Namyangju city, Korea. Five rainfall events were monitored during 2016 with ranging from 14.5 mm to 121.5 mm. The runoff ratio of CSO was higher than that of SSO because only design volume of maximum sanitary sewer ($1Q_h$) was transported and treated and $2Q_h$ was overflowed to waterbody during rainy day although combined sewer system was designed to transport $3Q_h$ to treatment system. The event mean concentrations (EMCs) and pollutant loads from CSO were higher than those from SSO. BOD and COD of CSO, and TOC and TN of SSO represented distinct first flush phenomena. The inadequate management in combined sewer system from which the untreated $2Q_h$ from CSO was overflowed to waterbody during rainy day could influence on high pollutant loads and first flushing. Treating $2Q_h$ from CSO, source control such as low impact development, and treating outflow from SSO were strongly recommended to control non-point source pollution in urban area.

Clinical evaluation of a collagen matrix to enhance the width of keratinized gingiva around dental implants

  • Lee, Kang-Ho;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.96-101
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of collagen matrix with apically positioned flap (APF) on the width of keratinized gingiva, comparing to the results of APF only and APF combined with free gingival graft (FGG) at the second implant surgery. Methods: Nine patients were selected from those who had received treatments at the Department of Periodontics, Chosun University Dental Hospital, Gwangju, Korea. We performed APF, APF combined with FGG, and APF combined with collagen matrix coverage respectively. Clinical evaluation of keratinized gingival was performed by measuring the distance from the gingival crest to the mucogingival junction at the mid-buccal point, using a periodontal probe before and after the surgery. Results: The ratio of an increase was 0.3, 0.6, and 0.6 for the three subjects in the APF cases, 3, 5, and 7 for the three in the APF combined with FGG case, and 1.5, 0.5, and 3 for the three in the APF combined with collagen matrix coverage case. Conclusions: This study suggests that the collagen matrix when used as a soft tissue substitute with the aim of increasing the width of keratinized tissue or mucosa, was as effective and predictable as the FGG.

A Simple If In-Phase Combiner and Its Performance for Point-to-Point Radio Relay System with Space Diversity

  • Suh Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The implementation of a simple analog in-phase combiner is presented for a high capacity radio relay system with space diversity. It provides good performance in terms of simple hardware and easy control, and measured results are in good agreement with simulated ones. To suggest practical applications, signatures with/without diversity are measured for STM-1 signal of 64-QAM radio relay system combined with a 13-tap equalizer, and they provided more than 25 dB fade depth at 10$^{-3}$ BER under the frequency selective fading condition.

EXISTENCE FOR A NONLINEAR IMPULSIVE FUNCTIONAL INTEGRODIFFERENTIAL EQUATION WITH NONLOCAL CONDITIONS IN BANACH SPACES

  • Yan, Zuomao
    • Journal of applied mathematics & informatics
    • /
    • v.29 no.3_4
    • /
    • pp.681-696
    • /
    • 2011
  • In this paper, we consider the existence of mild solutions for a certain class of nonlinear impulsive functional evolution integrodifferential equation with nonlocal conditions in Banach spaces. A sufficient condition is established by using Schaefer's fixed point theorem combined with an evolution system. An example is also given to illustrate our result.

Second Order Impulsive Neutral Functional Differential Inclusions

  • Liu, Yicheng;Li, Zhixiang
    • Kyungpook Mathematical Journal
    • /
    • v.48 no.1
    • /
    • pp.1-14
    • /
    • 2008
  • In this paper, we investigate the existence of solutions of second order impulsive neutral functional differential inclusions which the nonlinearity F admits convex and non-convex values. Some results under weaker conditions are presented. Our results extend previous ones. The methods rely on a fixed point theorem for condensing multivalued maps and Schaefer's fixed point theorem combined with lower semi-continuous multivalued operators with decomposable values.

Mathematical Analysis of the Structure of Korean Characters (한글문자의 인식에 관한 연구(IV))

  • 최주근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.4
    • /
    • pp.25-32
    • /
    • 1972
  • This paper: a) discusses the structure of Korean charactors from a unified point of view. The forming process of vowels, consonants, and the combined characters are described in the same way. b) makes clear that vowels and consonants are unique determinants of combined characters according to speech sound. c) describes the way in which 10 vowels and 14 consonants are arranged systematically by the matrix equation, which forms 14,364 kinds of combined characters.

  • PDF

Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL (345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토)

  • Jang, Hwa-Youn;Lee, Jong-Beom;Kim, Yong-Kap;Jang, Tae-In
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.