4-Tert-Octylphenol (OP) is a surfactant additive widely used in the manufacture of a variety of detergents and plastic products. OP can disrupt endocrine function in humans and animals. This study was carried out to obtain toxicokinetic parameters of OP in male Sprague-Dawley (SD) rats. Male rats were administered with OP by single oral application of 200 mg/kg body weight. Blood, urine and tissues samples were taken at several time intervals after administration. Analysis of samples for OP was performed by column-switching high performance liquid chromatography (HPLC). In addition, we exam-ined tissue distribution and accumulation of OP after single oral application of 50, 100, and 200 mg/kg, single intravenous injection of 1, 5 and 10 mg/kg or daily application of 50 mg/kg for 14 consecutive days. After single oral administration of 200 mg/kg, Cmax of 213 $\pm$ 123 ng/ml was reached within the first 1.3 hr (Tmax) in the plasma. AUC was calculated for 1,333$\pm$484 ngㆍhr/ml. The final elimination half-life of plasma was longer than that of urine, but urinary clearance was lower than oral. A very small fraction of OP (Fe < 0.0017%) was excreted in urine within 24 hr. These results indicated that the major excretion route of OP was not urine. The mean maximal tissue distribution of OP was obserbed at 6 hr after treatment and slowly decreased time-dependently. High OP concentrations were detected in fat at 24 hr. The OP in fat was slowly released with longer elimination half-life and lower clearance than that of other tissues. OP was not accumulated in the liver following single oral application but 14-day oral treatments resulted in two-fold accumulation. It was probably due to the saturation of detoxification pathways. On the other hand, the mRNA expression of cytochrome P450 isoforms except CYP2C11 was not affected by OP at any dose. The expression of CYP2C11 mRNA decreased in a dose-dependent manner. This result suggests that OP changes expression of the male-specific cytochrome P450 isoforms in rat liver, and these changes are closely related to the toxic and estrogenic effect of OP.
The bioequivalence of two triflusal products was evaluated with 20 healthy volunteers following single oral dose according to the guidelines of Korea Food and Drug Administration (KFDA). Trisa $l^{R}$ capsule (Whanin Pharm. Corp., Korea) and Disgre $n^{R}$ capsule (Myung-In Pharm. Corp., Korea) were used as test product and reference product, respectively. Both products contain 300 mg of trifusal. One capsule of test product or reference product was orally administered to the volunteers, respectively, by randomized two period crossover study (2$\times$2 Latin square method). Blood samples were taken at predetermined time intervals for 4 hours and the determination of trifusal was accomplished using semi-microbore HPLC equipped with automated column switching system. The analytical method with HPLC was validated according to the Bioanalytic Method Validation guideline by F7A prior to determining the plasma samples. The pharmacokinetic parameters (AU $C_{0-4h}$$C_{max}$ and $T_{max}$) were calculated and ANOVA test was utilized for statistical analysis of parameters. As a result of the assay validation, the limit of quantification of trifusal in human plasma by current assay procedure was 50 ng/ml using 500 $\mu$l of plasma. The accuracy of the assay was from 97.76% to 116.51% while the intra-day and inter-day coefficient of variation of the same concentration range was less than 15%. Average drug concentration at the designated time intervals and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05). The difference of mean AU $C_{olongrightarrow4hr}$, $C_{max}$, and $T_{max}$ between the two products (2.92, 4.39, and -2.44%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $C_{olongrightarrow4hr}$ and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for $T_{max}$ was under 0.8, $T_{max}$ of the two products was not significantly different from each other (p>0.05). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating the two products of triflusal were bioequivalent.quivalent.ent.ent.
Dialkylated phthalates have been commonly used as plasticizers and a variety of applications. Phthalate diesters have been shown to be developmental and reproductive toxicants. It is very difficult to exactly estimate the dose of dialkylated phthalates taken up by the general population because of environmental contamination. Urinary metabolites of phthalates enabled to estimate internal exposure. The objective of this study was quantitative determination of phthalate metabolites by LC/MS/MS with on-line cleanup method to analyze phthalate metabolites in Korean children's urine. We employed LC/MS/MS with on-line enrichment and column-switching techniques for this biological monitoring. Metabolites determined were 4 primary metabolites; MEHP, MnBP, MiBP, MEP and 2 secondary metabolites of DEHP; 5-OH-MEHP), 5-oxo-MEHP. We analyzed children's urine from 30 boys and 30 girls. The method detection limit of phthalate metabolites were 0.03 ng/mL for MEP, 1.05 ng/mL for MBP, 0.22 ng/mL for MEHP, 0.15 ng/mL for 5-OHMEHP and 0.16 ng/mL for 5-oxo-MEHP, respectively. Switching Column LC/MS/MS was proven to be a useful tool to determine metabolites of phthalate diesters in human urine. The correlation among phthalate metabolites was very high and statistically significant, except MEP. The children's age (months) was negatively correlated to the concentration of phthalate metabolites. The geometric mean concentration of phthalate metabolites (mg/g creatinine) in children's urine were 25.5 for MEP, 130.3 for MnBP, 56.8 for MiBP, 19.5 for MEHP, 85.6 for 5-OH-MEHP and 83.1 for 5-oxo-MEHP, respectively. Levels of estimated daily intake of parent phthalate compounds (${\mu}g$/kg bw/day) were 0.8 for DEP, 5.0 for DnBP, 1.9 for DiBP and $8.9{\sim}14.2$ for DEHP, respectively. Estimated daily intake for DEP and DiBP were lower than those of other studies but the value for DEHP was higher than that of other study.
본 논문은 기하학적 비선형성을 가진 보존적 단일 하중 매개변수의 탄성 상태 공간구조의 탄성 분기 좌굴해석을 위한 공간프레임의 정식화, 분기경로 추적을 위한 pin-pointing 및 분기경로 전환알고리즘을 기술하고 있다. 복잡한 좌굴 후 거동특성을 파악하기 위한 본 연구의 공간프레임요소는 오일러리안 좌표계에 의한 유한회전이론으로 강체변형을 계산하였고, 굽힘효과가 고려된 보-기둥식을 적용하여 적은 개수의 요소의 사용으로도 정해를 얻을 수 있도록 하였으며, 후좌굴해석과 같은 고도의 비선형해석을 수행하기 위해 기하강성행렬의 모멘트에 대한 영향을 고려하였다. 분기좌굴에 의한 좌굴후 평형상태인 주경로와 분기경로의 pin-pointing 알고리즘으로 특이점을 계산하였으며, 고유치 및 고유모드를 이용한 본 연구의 수치알고리즘에 의해 분기경로를 추적하였다. 분기좌굴 해석예제로 평면프레임, 평면아치 및 공간돔에 대한 분기좌굴 해석을 수행하여 본문에서 제시한 수치해석법의 정확성 및 적용성을 검증한다.
본 논문에서는 크로스(CROSS) 포트에 광섬유 지연선로가 연결된 $2\times2$ 광 스위치들로 구성된 광섬유 지연선로 행렬과 다파장 광원을 이용한 2차원 위상 배열 안테나(Phased Array Antenna; PAA)용 광 실시간 지연선로(True Time-Delay ; TTD)의 구조를 제안하였고, 파장 의존형 광 TTD와 파장 비의존형 광 TTD를 결합하여 10-GHz 2차원 PAA용 2-비트$\times$4-비트 광 TTD를 제작하였다. 단위 시간 지연 차이가 각각 ${\Delta}T=12ps$와 $\Delta\tau=6ps$인 파장 의존형 광 TTD와 파장 비의존형 광 TTD의 모든 주사각에 대해서 시간지연을 측정하였다. 파장 의존형 광 TTD의 시간 지연 오차는 지터에 의해 최대 2.8 ps가 발생하였으며, 파장 비의존형 광 TTD의 경우에는 ${\pm}0.8ps$이하의 오차가 나타났다. 제안된 2차원 PAA용 광 TTD의 구조는 1차원 선형 PAA보다 높은 이득을 얻을 수 있고, 다파장 광원을 사용하므로 광 파워 및 파장의 안정성을 확보할 수 있으며, 전기적 스위치 제어기를 이용하여 $2\times2$ 광 스위치 행렬을 열(column) 단위로 절체하기 때문에 주사 빔 제어 속도가 빠르고 구동이 간단한 장점을 갖고 있다.
본 논문에서는 수동형 900MHz RFID 태그 칩용 로직 공정 기반 저면적.저전력 1Kb EEPROM를 설계하였다. 1Kb 셀 배열 (cell array)은 1 워드 (word)의 EEPROM 팬텀 셀 (phantom cell)을 2차원 배열 형태인 (16행 ${\times}$ 16열) ${\times}$ 4블록으로 구성하였으며, 4개의 메모리 블록이 CG (Control Gate)와 TG (Tunnel Gate) 구동회로를 공유하므로 저면적 IP 설계를 하였다. TG 구동회로를 공유하기 위해 소자간의 전압을 신뢰성이 보장되는 5.5V 이내로 유지하면서 동작 모드별 TG 바이어스 전압을 스위칭해 주는 TG 스위치 회로를 제안하였다. 그리고 4 메모리 블록 중 하나의 블록만 활성화하는 partial activation 방식을 사용하므로 읽기 모드에서 전력소모를 줄였다. 그리고 하나의 열 (column)당 연결되는 셀의 수를 줄이므로 읽기 모드에서 BL (Bit-Line)의 스위칭 시간을 빠르게 하여 액세스 시간 (access time)을 줄였다. Tower $0.18{\mu}m$ CMOS 공정을 이용하여 (32행 ${\times}$ 16열) ${\times}$ 2블록과 (16행 ${\times}$ 16열) ${\times}$ 4블록의 2가지 배열 형태의 1Kb EEPROM IP를 설계하였으며, (16행 ${\times}$ 16열) ${\times}$ 4블록의 IP가 (32행 ${\times}$ 16열) ${\times}$ 2블록의 IP에 비해 레이아웃 면적은 11.9% 줄였으며, 읽기 모드 시 전력소모는 51% 줄였다.
Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.
This study was conducted to provide a vitamin $B_{12}$ database for the representative Korean food items and to assess the dietary intake assessment of vitamin $B_{12}$ for Koreans. The vitamin $B_{12}$ content of 106 foods had been determined by high performance liquid chromatography (HPLC) using column switching method. Rich sources of vitamin $B_{12}$ were meats, milk, and egg ($0.3-3.4\;{\mu}g/100g$). Vegetables and fruits contained vitamin $B_{12}$ below limit of detection (LOD). The major food sources for vitamin $B_{12}$ intake were milk (72.0%), meats (22.3%), egg (3.6%), and fishes & shellfishes (2.1%). Mean vitamin $B_{12}$ intake of Koreans was $3.16\;{\mu}g$/person/day. The proportion of population with intake below estimate average requirement (EAR) and above recommended intake (RI) of vitamin $B_{12}$ was 60.7 and 36.5%, respectively. The vitamin $B_{12}$ intake level of young children with 1-2 years which was 834.6% of RI while the intake level of the older adults 50 years and older was only 70.0% of RI. Also, there were regional differences between urban and rural area. The population with intake below RI was larger than that with intake above RI in Korea.
JSTS:Journal of Semiconductor Technology and Science
/
제8권2호
/
pp.128-133
/
2008
Phase-change random access memory (PRAM) chip cell phase of amorphous state is rapidly changed to crystal state above 160 Celsius degree within several seconds during Infrared (IR) reflow. Thus, on-board programming method is considered for PRAM chip programming. We demonstrated the functional 512Mb PRAM with 90nm technology using several novel core circuits, such as metal-2 line based global row decoding scheme, PN-diode cells based BL discharge (BLDIS) scheme, and PMOS switch based column decoding scheme. The reverse-state standby current of each PRAM cell is near 10 pA range. The total leak current of 512Mb PRAM chip in standby mode on discharging state can be more than 5 mA. Thus in the proposed BLDIS control, all bitlines (BLs) are in floating state in standby mode, then in active mode, the activated BLs are discharged to low level in the early timing of the active period by the short pulse BLDIS control timing operation. In the conventional sense amplifier, the simultaneous switching activation timing operation invokes the large coupling noise between the VSAREF node and the inner amplification nodes of the sense amplifiers. The coupling noise at VSAREF degrades the sensing voltage margin of the conventional sense amplifier. The merit of the proposed sense amplifier is almost removing the coupling noise at VSAREF from sharing with other sense amplifiers.
이 논문은 필리핀 석회석 광산에 적용한 연구 결과로서 이 광산에서는 파쇄석 입도분포가 좋지 않고 벽면의 유지나 파쇄석 더미의 분산이 불량하였다. 기폭패턴을 대각선 방식에서 V 타입으로 바꾸고 전색장을 조정하여 저항과 가스압의 유지기간을 향상시켰다. 이를 통하여 발파결과가 향상되었다. 특히 공당발파영역이 넓어진 것으로써 그 성과를 확인할 수 있다. 공당발파영역은 기존의 $8.96m^2$에서 $12m^2$로 넓어졌다. 화약계수는 증가하였고 대괴의 수는 감소하였으며, 전방적재기의 행정시간이 감소하였다. 또 공전 시간이 줄었으며 적재높이가 향상되었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.