• Title/Summary/Keyword: Column study

Search Result 5,305, Processing Time 0.032 seconds

An Experimental Study on the Structural Behavior of Strengthened Reinforced Concrete Columns (보강된 철근콘크리트 기둥의 구조거동에 관한 실험적 연구)

  • 이승엽;정성원;황규표;장성재;음성우;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.665-672
    • /
    • 1997
  • In this paper, sixteen column specimens were tested under the concentrated and excentric load condition to examine the structural behavior of strengthened columns. 16 column specimens were divided into four groups. One group is not strengthened, the other three groups are strengthened by the materials : 1) steel plate, 2) carbon fiber sheet, and 3) glass fiber sheet, each group is composed of four specimens. As a result, strengthened columns have larger bearing capacity and energy absorption after ultimate load than unstrengthened columns. The column group strengthened with steel plate has the best bearing capacity among the strengthened column groups. Also, the columns strengthened with the carbon fiber sheet are similar to glass fiber sheet in bearing capacity. If necessary to strengthen columns in trouble, car should be taken to treat the joint between beam and column because of crack propagation in tension side.

  • PDF

Pullout Test of Headed Reinforcement 2: Deep Embedment

  • Choi, Dong Uk;Shin, InYong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1091-1096
    • /
    • 2003
  • Pullout tests of single headed bars using plain concrete blocks indicate that the embedment depth of $10d_b$ is in general required for the headed bars to develop pullout strength equivalent to 125% of bar yield strength. In this experimental study, test results of multiple headed bars installed in reinforced concrete column sections are presented. Test variables included embedment depth, column main reinforcement ratio, and spacing of column ties. 2D29 bars were pulled out at one time from normal strength concrete. Test results indicated that the embedment depths, column tie spacings, and column main reinforcement ratios all influenced the pullout strengths of the headed bars. When the embedment depth was not sufficient, narrow tie spacings especially resulted in increased pullout strengths of the headed bars. Test results also indicated that the embedment depth of 15㏈ was sufficient for the closely spaced two headed bars (head-to-head spacing =$6d_b$) to develop pullout strength equivalent to 125% of the bar yield strength.

  • PDF

Impedance-based damage monitoring of steel column connection: numerical simulation

  • Ho, Duc-Duy;Ngo, Thanh-Mong;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.339-356
    • /
    • 2014
  • This study has been motivated to evaluate the practicality of numerical simulation of impedance monitoring for damage detection in steel column connection. In order to achieve the objective, the following approaches are implemented. Firstly, the theory of electro-mechanical (E/M) impedance responses and impedance-based damage monitoring method are outlined. Secondly, the feasibility of numerical simulation of impedance monitoring is verified for several pre-published experimental examples on steel beams, cracked aluminum beams, and aluminum round plates. Undamaged and damaged steel and aluminum beams are simulated to compare to experimental impedance responses. An aluminum round plate with PZT patch in center is simulated to investigate sensitive range of impedance responses. Finally, numerical simulation of the impedance-based damage monitoring is performed for a steel column connection in which connection bolts are damaged. From the numerical simulation test, the applicability of the impedance-based monitoring to the target steel column connection can be evaluated.

Influence of shear deformation of exterior beam-column joints on the quasi-static behavior of RC framed structures

  • Costa, Ricardo J.T.;Gomes, Fernando C.T.;Providencia, Paulo M.M.P.;Dias, Alfredo M.P.G.
    • Computers and Concrete
    • /
    • v.12 no.4
    • /
    • pp.393-411
    • /
    • 2013
  • In the analysis and design of reinforced concrete frames beam-column joints are sometimes assumed as rigid. This simplifying assumption can be unsafe because it is likely to affect the distributions of internal forces and moments, reduce drift and increase the overall load-carrying capacity of the frame. This study is concerned with the relevance of shear deformation of beam-column joints, in particular of exterior ones, on the quasi-static behavior of regular reinforced concrete sway frames. The included parametric studies of a simple sub-frame model reveal that the quasi-static monotonic behavior of unbraced regular reinforced concrete frames is prone to be significantly affected by the deformation of beam-column joints.

A study on the finish work of Reinforced Con'c slab for improving workability in the column shortening compensation. (기둥축소량 보정법에 있어서 시공성 향상을 위한 RC 슬래브 표면마무리에 관한 연구)

  • 소광호;이재옥;양극영
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.147-152
    • /
    • 2003
  • Passage of time axial shortening in the cores and columns of tall concrete buildings requires special attention to ensure proper behavior for strength of the structure and the nonstructural element. The effects of column shortening, both elastic and inelastic, take on added significance and need special consideration in design and construction with increased height of structures. In this paper, the compensation method of column shortening for reinforced concrete structure are introduced. It could be concluded that the survey is a significant factor for the compensation instance of column shortening.

  • PDF

Analytical Study of HAT Joint between PHC Pile and Steel Tube Column (강재기둥과 PHC 파일을 연결하는 반구형 접합부(HAT Joint)의 유한요소 해석 PART II : 각형강관기둥)

  • Oh, Jin-Tak;Lee, Yeun-Seung;Kim, Sang-Bong;Ju, Young-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.1
    • /
    • pp.111-118
    • /
    • 2015
  • In Part I, we disccussed of joint between PHC pile and steel column in foundation of large space structures, one prototype of a joint of PHC pile to steel pipe column was suggested on the basis of analytical studies. In this paper, I explain the Joint of PHC pile to steel tube column and more detail of analysis.

Analytical Study of HAT Joint between PHC Pile and Steel Pipe Column (강재기둥과 PHC 파일을 연결하는 반구형 접합부(HAT Joint)의 유한요소 해석 PART I : 원형강관기둥)

  • Oh, Jin-Tak;Lee, Yeun-Seung;Kim, Sang-Bong;Ju, Young-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.1
    • /
    • pp.103-110
    • /
    • 2015
  • To overcome disadvantages of usual spread foundation in large space structure, some prototypes of a joint of the PHC pile to steel pipe column that directly connects a column to a PHC pile are analytically studied. With the consideration of strength requirement and stress concentration of joint of the PHC pile to column, we suggest the most appropriate one.

A Study on the Eddy Diffusion in a Pulsed Turbulent System (脈動渦流裝置에 있어서의 渦流擴散)

  • Woong Ki Kang;Yung Wook Kim
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.203-206
    • /
    • 1963
  • The eddy diffusion in the pulsed wetted wall column, where the spherical balls are consecutively arrayed along the axis of the column and turbulence is caused around the balls by pulsation, has been studied both theoretically and experimentally. A diffusion equation is solved for a longitudinal column where a concentration impulse is given at the top of the column, and the experimental results, which are the impulse response measurements at the half of the total height of the column, have shown a good agreement with the developed theory. A method of measuring the eddy diffusivity, which is based on the slope of concentration vs. time in the particular interval of concentration, is proposed and the measured diffusivity is used as a criterion of comparing the theory and the experiment. The eddy diffusion is remarkably increased as the amplitude and the frequency of the pulsation increase but the increasing rate is decreased as the pulsation increases.

  • PDF

Free Vibrations and Buckling Loads of Column with Clamped-Spring Ends and Constant Volume (고정-스프링 일정체적 기둥의 자유진동 및 좌굴하중)

  • Yoon, Hee-Min;Lee, Tae-Eun;Park, Kwang-Kyu;Lee, Byoung-Koo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.117-120
    • /
    • 2007
  • This study deals with the free vibrations and buckling loads of column with clamped-spring ends and constant volume. The column has the regular polygon cross-section whose depth is varied with the linear functional fashion. The differential equation governing the free vibration of such column is derived in which the effect of axial load is included. The differential equation is solved numerically for calculating frequencies. By using the relationship between loads and frequencies, the buckling loads are also obtained.

  • PDF

Analysis of Orientation and Distribution of Steel Fiber in Fiber Reinforced Concrete Column by Micro-CT Scanning (Micro-CT 스캐닝을 통한 섬유보강 콘크리트 기둥내부 강섬유의 배향성 및 위치분포 분석)

  • Park, Tae-Hoon;Suh, Heong-Won;Bae, Sung-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.23-24
    • /
    • 2019
  • In this study, analysis of steel fiber orientation and distribution inside fiber reinforced concrete was performed using micro-CT scanning technology. Samples were extracted from the column according to its height and distance from the mold. Samples were scanned in order to attain the image of steel fibers then region of interest were obtained by binarization process. By calculating the principle moment of inertia of each fiber, direction vector, scale, center postion, volume, and surface area were gained in order to analyze the orientation and distribution. Most of the fibers inside the column tended to be perpendicular to the main axis of the column. Moreover, most of the fibers appeared at the bottom of the column and at the position where it is farthest from the mold.

  • PDF