• 제목/요약/키워드: Column Sidesway

검색결과 6건 처리시간 0.015초

신보강재로 보수 보강한 기둥의 구조 성능 개선 (Structural Performance Enhancement of Seismic Retrofitted Column Using New Reinforcing Materials)

  • 오창학;한상환;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.121-128
    • /
    • 2001
  • Reinforced concrete frame buildings in regions of low to moderate seismicity are typically designed only for gravity loads with non-seismic detailing provisions of the code. These buildings possess strong beam-weak column, which brings about the brittle structural performance like the column sidesway failure mechanism during the strong lateral load. The objective of this paper is to enhance the column strength and deformation capacity for reconfiguring the structural failure mode by averting a column soft-story collapse and moving to a more ductile beam-sides way mechanism suing new reinforcing materials. Aramid fiber sheet and reinforcing rod-composite materials was used for this purpose. The column was modeled by the 2/3 scale experimental specimen retested. According to the concept of the capacity design, the damaged column was strengthened by the column jacketing using new reinfocing materials such as rod-composite materials. In conclusion, the improvement of the flexural strength is observed and the capacity of the energy dissipation and the ductility is enhanced, too.

  • PDF

수평력과 축력을 받는 강골조의 최대수평내력 평가 (Evaluation of the Lateral Ultimate Strength of Steel Moment Resisting Frames under Axial and lateral Forces)

  • 김종성
    • 한국강구조학회 논문집
    • /
    • 제11권1호통권38호
    • /
    • pp.69-78
    • /
    • 1999
  • 구조물이 지진과 같은 수평력을 받으면 골조의 기둥은 횡이동을 하게 되고 이 횡이동이 크면 골조는 불안정 좌굴, 초기항복, 골조전체의 강성이 감소하게 된다. 본 연구에서는 이러한 골조의 기둥이 횡이동에 의해 수평력과 축력을 동시에 받는 강골조를 대상으로하여 골조강성의 저하, 보와 기둥의 상대적인 강성비, 세장비효과, 하중조건 등을 고려한 다양한 해석모델을 상정하여 수치해석을 실시했다. 그 해석결과를 분석하여 강골조의 최대수평내력을 평가하고, 기둥의 세장비 제한치를 구하는 절차에 대해서도 검토한다. 해석에 있어서는, 골조의 $P-{\Delta}$효과를 고려해서 기발표된 저자의 탄소성해석법을 이용하여 일정한 축력하에 점증의 수평력을 골조에 가했으며, 최대내력후의 해법으로서 일반역행렬을 응용했다.

  • PDF

Stability and minimum bracing for stepped columns with semirigid connections: Classical elastic approach

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.415-431
    • /
    • 1997
  • Stability equations that evaluate the elastic critical axial load of stepped columns under extreme and intermediate concentrated axial loads in any type of construction with sidesway totally inhibited, partially inhibited and uninhibited are derived in a classical manner. These equations can be utilized in the stability analysis of framed structures (totally braced, partially braced, and unbraced) with stepped columns with rigid, semirigid, and simple connetions. The proposed column classification and the corresponding stability equations overcome the limitations of current methods which are based on a classification of braced and unbraced columns. The proposed stability equations include the effects of: 1) semirigid connections; 2) step variation in the column cross section at the point of application of the intermediate axial load; and 3) lateral and rotational restraints at the intermediate connection and at the column ends. The proposed method consists in determining the eigenvalue of a $2{\times}2$ matrix for a braced column at the two ends and of a $3{\times}3$ matrix for a partially braced or unbraced column. The stability analysis can be carried out directly with the help of a pocket calculator. The proposed method is general and can be extended to multi-stepped columns. Various examples are include to demonstrate the effectiveness of the proposed method and to verify that the calculated results are exact. Definite minimum bracing criteria for single stepped columns is also presented.

고강도 표면매립용철근과 탄소섬유시트로 보강된 비연성 철근콘크리트 골조의 실물 진동기 실험 (Full-Scale Shaker Testing of Non-Ductile RC Frame Structure Retrofitted Using High-Strength Near Surface Mounted Rebars and Carbon FRP Sheets)

  • 신지욱;전종수
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.43-54
    • /
    • 2019
  • Existing reinforced concrete frame buildings designed for only gravity loads have been seismically vulnerable due to their inadequate column detailing. The seismic vulnerabilities can be mitigated by the application of a column retrofit technique, which combines high-strength near surface mounted bars with a fiber reinforced polymer wrapping system. This study presents the full-scale shaker testing of a non-ductile frame structure retrofitted using the combined retrofit system. The full-scale dynamic testing was performed to measure realistic dynamic responses and to investigate the effectiveness of the retrofit system through the comparison of the measured responses between as-built and retrofitted test frames. Experimental results demonstrated that the retrofit system reduced the dynamic responses without any significant damage on the columns because it improved flexural, shear and lap-splice resisting capacities. In addition, the retrofit system contributed to changing a damage mechanism from a soft-story mechanism (column-sidesway mechanism) to a mixed-damage mechanism, which was commonly found in reinforced concrete buildings with strong-column weak-beam system.

Braced, partially braced and unbraced columns: Complete set of classical stability equations

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • 제4권4호
    • /
    • pp.365-381
    • /
    • 1996
  • Stability equations that evaluate the elastic critical axial load of columns in any type of construction with sidesway uninhibited, partially inhibited, and totally inhibited are derived in a classical manner. These equations can be applied to the stability of frames (unbraced, partially braced, and totally braced) with rigid, semirigid, and simple connections. The complete column classification and the corresponding three stability equations overcome the limitations and paradoxes of the well known alignment charts for braced and unbraced columns and frames. Simple criteria are presented that define the concept of partially braced columns and frames, as well as the minimum lateral bracing required by columns and frames to achieve non-sway buckling mode. Various examples are presented in detail that demonstrate the effectiveness and accuracy of the complete set of stability equations.

Stability analysis of truss type highway sign support structures

  • Yang, Jun;Culmo, Michael P.;Dewolf, John T.
    • Wind and Structures
    • /
    • 제7권6호
    • /
    • pp.393-404
    • /
    • 2004
  • The design of truss type sign support structures is based on the guidelines provided by the American Association of State Highway and Transportation Officials Standard Specifications for Highway Signs, Luminaries and Traffic Signals and the American Institute of Steel Construction Design Specifications. Using these specifications, the column design strength is normally determined using the effective length approach. This approach does not always accurately address all issues associated with frame stability, including the actual end conditions of the individual members, variations of the loads in the members, and the resulting sidesway buckling for truss type sign support structures. This paper provides insight into the problems with the simplified design approach for determining the effective lengths and discusses different approaches for overcoming these simplifications. A system buckling approach, also known as a rational buckling analysis, is used in this study to determine improved predictions for design strength of truss type sign support structures.