• 제목/요약/키워드: Column Mixer

검색결과 9건 처리시간 0.02초

화학 플랜트용 칼럼믹서의 ADINA/FSI 해석 (ADINA/FSI Analysis of Petrochemical Plant Column Mixer)

  • 이원석;정구충;최연선
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.213-219
    • /
    • 2007
  • Column mixer Is one of the facilities to mix fluids at petrochemical plants. The vibration of column mixer is usually caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced nitration is mainly responsible for the reduction of column life. Measurements were performed for understanding the vibration characteristics of the column. First measurement results showed the need of stiffness reinforcement. After the reinforcement work, second measurement confirmed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm fluid induced vibration at the column mixer fluid structure interaction analysis using ADINA/FSI was performed, which showed the necessity of the modification of the rotary valve.

화학 플랜트용 칼럼 믹서의 ADINA/FSI 해석 (ADINA/FSI Analysis of Petrochemical Plant Column Mixer)

  • 이원석;정구충;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.916-921
    • /
    • 2006
  • Column mixer is one of the facility to mix fluids at petrochemical plants. The column vibration is caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced vibration is mainly responsible for the reduction of column life. Measurements were performed three times for understanding the vibration characteristics of the column. First experimental results showed the need of stiffness reinforcement. After the reinforcement work, second measurement conformed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm the generation of the fluid instability in the column mixer fluid structure interaction analysis using ADINA/FSI was performed which showed the necessity of the modification of the rotary valve.

  • PDF

폐촉매(廢觸媒) 염산침출액(鹽酸浸出液)에서 컬럼형 추출기(抽出器)에 의한 백금(白金) 회수(回收) (Recovery of Pt from the Chloride Leaching Solution of Spent Catalysts by using Column Extractor)

  • 손반반;이만승
    • 자원리싸이클링
    • /
    • 제22권6호
    • /
    • pp.26-32
    • /
    • 2013
  • 폐촉매 염산 침출액으로부터 백금을 회수하기 위해 벤치규모의 Karr 왕복 추출기를 사용하였다. 최적의 유량속도와 진동 빈도에서 철과 백금은 TBP와 Aliquat 336에 의해 모두 추출되었다. 같은 진동 빈도에서 유량을 조절함으로써 염산과 과염소산을 사용하여 철과 백금을 모두 탈거하였다. TEHA를 사용하여 추출여액으로부터 염산을 추출하는 경우 컬럼 추출기의 안정성을 유지하기 어려웠다. 컬럼 추출기와 mixer-settler에 의한 조업 결과를 비교하였다.

가스 크로마토그래픽 컬럼의 유동특성에 대한 수치적 연구 (A NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF GAS CHROMATOGRAPHIC COLUMN)

  • 김태안;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.21-26
    • /
    • 2005
  • Gas Chromatography (GC) is a wisely technique used for the separation and analysis of liquid and gas sample. Separation of the sample vapors is achieved via their differential migration through a capillary column with an insert carrier gas. The identity and quantity of each vapor in the mixer can be determined from its retention time in the column and a particular property of the gas, such as thermal conductivity, which can be related to the concentration of sample vapor in the carrier gas. Therefore, the flow characteristics in the spiral gas chromatographic column are numerically investigated in this study. Especially, different pressure drop between the front and the rear of GC column with various flow rates is estimated the governing equations are derived from making using of three-dimensional Naver-Stokes equation with incompressible and laminar model due to the nature of low Reynolds number flow. Using a commercial code, FLUENT, the pressure and flow fields in GC column are calculated with various flow rates. The characteristics of thermal cycling which is one of the most important factors affecting the column efficiency and analysis time is also estimated. Furthermore, numerical analyses are also carried out by using commercial code, ANSYS, with various values of power, which is applied to the heating element located at lower GC column.

  • PDF

Predispersed Solvent Extraction of Succinic Acid Aqueous Solution by Colloidal Liquid Aphrons in Column

  • Kim Bong Seock;Hong Yeon Ki;Huh Yun Suk;Hong Won Hi
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.454-458
    • /
    • 2004
  • A study of the POSE (predispersed solvent extraction) for succinic acid by colloidalliq­uid aphrons was conducted. The organic phase contaning TOA (tri-n-octylamine) and 1-octanol permits a selective extraction of succinic acid from its aqueous solution. There was no difference of the extractability of POSE and that of conventional mixer-settler type extraction. Taking into account the no mechanical mixing in POSE, it was concluded that the POSE process is more adaptive than the conventional mixer-settler type extraction process. From mass transfer analysis at the various concentration of TOA in counter-current continuous operation, the concentration of TOA had no influence on the mass transfer coefficient. The loading values in continuous POSE were almost same as those in batch operation.

180MPa 초고성능 콘크리트의 압축 부재에의 적용성에 대한 연구 (A Study for Application of 180 MPa Ultra High Performance Concrete to Compressive Members)

  • 민경환;최홍식
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4930-4935
    • /
    • 2015
  • 180MPa급 초고성능 콘크리트는 높은 압축강도로 인해 압축 부재에 대한 연구 결과가 부족한 실정이다. 본 연구에서는 UHPC의 적용성 향상을 위해 트윈 샤프트 믹서 배치 플랜트에서 생산성을 평가하였다. 또한 설계 방안을 제시하기 위한 기초 자료를 획득하기 위해 사각 기둥과 원형 기둥에 대한 중심축하중 실험을 수행하여 파괴 형태와 거동을 평가하였다.

HPLC-PDA를 이용한 정향(Eugenia caryophyllata) 중의 eugenol 분석법 확립 및 검증 (Determination of eugenol in Eugenia caryophyllata by high-performance Liquid chromatography with photodiode array detection and method validation)

  • 윤형준;윤소미;이명헌;손성완
    • 대한수의학회지
    • /
    • 제48권1호
    • /
    • pp.9-16
    • /
    • 2008
  • A method for the quantification of eugenol in the medicinal herb Clove was developed and validated. For preparation of sample solutions clove was dried at $60^{\circ}C$ for 2h and ground by mixer and extracted with 95% ethanol for shaking extraction. The elutes were analyzed by HPLC system included a reversed phase column, a isocratic mobile phase of 60% methanol and PDA detector set at 280 nm. Calibration graphs were linear with very good correlation coefficients ($r^2>0.9999$) from $0.0125~1{\mu}g/ml$. The limit of detection per sample injection ($20{\mu}l$) was $0.81ng/{\mu}l$ and limit of quantification was $2.47ng/{\mu}l$. The method showed good intra-day precision (%RSD 0.08 ~ 0.27%) and inter-day precision (%RSD 0.32 ~ 1.19%).

역류형 컬럼 부선기를 이용한 석탄회정제에 관한 연구 (Removal of Unburned Carbon from Fly Ash using Countercurrent Column Flotation Cell)

  • 이전언;이제군
    • 자원리싸이클링
    • /
    • 제8권5호
    • /
    • pp.51-58
    • /
    • 1999
  • 석탄화력 발전소에서 발생하는 수백만 톤의 석탄회는 콘크리트 혼화재 및 건축자재로 재활용이 가능함에도 불구하고 과다한 미연탄소 함량으로 인해 대부분 회사장(Ash Pond) 되는데, 이로 인해 환경오염유발, 회사장 포화에 따른 발전소의 수명 감소, 그리고 재활용 가능한 자원의 낭비와 같은 문제가 발생한다. 본 연구는 석탄회 내의 미연탄소분을 분리하여 미연탄소분 함량이 낮은 고순도 석탄회를 회수하기 위해 직류관 믹서(In-Line Mixer) 발생기키는 역류형 컬럼부선기를 이용하였다. 이때 입자 표면에 소수성의 특성을 강화시키는 포스제의 증가에 따른 석탄회와 미연탄소 입자의 분리 특성을 분석하였다. 석탕회 톤당 8ι의 포수제를 사용한 역류형 컬럼 부선기를 이용하여 미연탄소분 함유량이 7%인 석탄회를 분리 실험한 결과 미연탄소분 함유량 0.5%인 고순도 석탄회를 88.2% 회수하였다. 그리고 질량 평균입경이 21.2$mu extrm{m}$인 석탄회를 분리 실험하여 입도를 분석한 결과 분리 정도에 따라 입도는 뚜렷하게 구별되어 나타났는데, 분리효율이 증가할수록 정제 석탄회의 경우 입도는 조대해져 입도 분포의 양극화 현상이 뚜렷하게 나타났다. 포수제의 투입량이 증대함에 따라 미연탄소 입자의 계면에 소수성이 강화되어 분리 특성이 향상되었으며, 이때 회수한 고순도 석탄회의 입도는 미세화 되는 경향이 나타났다.

  • PDF

인삼 중 DDT(DDD 및 DDE) 분석법의 개발 (Development of a Simultaneous Analysis Method for DDT (DDD & DDE) in Ginseng)

  • 김성단;조태희;한은정;박성규;한창호;조한빈;최병현
    • 한국식품과학회지
    • /
    • 제40권2호
    • /
    • pp.123-128
    • /
    • 2008
  • GC-${\mu}$ECD 이용한 수삼, 건조인삼, 홍삼 중 DDT(o,p'-DDE, p,p'-DDE, o,p'-DDD, p,p'-DDD, o,p'-DDT, p,p'-DDT)의 효율적인 분석방법을 살펴본 결과는 다음과 같다. 단순하며 소량의 용매를 사용하는 동시분석법을 이용하여 인삼으로부터 DDT(DDD 및 DDE포함)를 추출하고 헥산 및 6% 에테르 함유 헥산으로 SPE-Florisil(500 mg) 정제하는 것이 GC-${\mu}$ECD 크로마토그램에서 인삼고유성분과 DDT(DDD 및 DDE포함) 피크의 분리도와 회수율 측면에서 가장 효율적이었다. 또한 인삼 중 저농도(0.01-0.05 mg/kg) DDT(DDD 및 DDE포함) 이성질체를 SPE-Florisil(500 mg) 정제 전 30% 황산 처리 후 원심분리로 인삼 고유성분을 제거하여 정확성을 높였다. 동시다성분법 추출 후 황산처리 및 SPE-Florisil(500 mg) 정제방법을 이용한 수삼, 건조 인삼분말, 홍삼분말에 DDT(DDD 및 DDE포함) 이성질체 표준용액을 0.01 mg/kg 농도가 되도록 첨가하여 실험한 회수율은 87.9-99.6%이었으며 표준편차는 0.9-5.9%였다. 또한 검출한계(Method Detection Limits)는 0.003-0.009 mg/kg이었다.